Prosecution Insights
Last updated: November 17, 2026
Application No. 17/128,561

DETERMINING THE STATE OF AN ULTRASONIC ELECTROMECHANICAL SYSTEM ACCORDING TO FREQUENCY SHIFT

Non-Final OA §112
Filed
Dec 21, 2020
Priority
Dec 28, 2017 — provisional 62/611,340 +17 more
Examiner
OU, JING RUI
Art Unit
3771
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Ethicon LLC
OA Round
3 (Non-Final)
54%
Grant Probability
Moderate
3-4
OA Rounds
99%
With Interview

Examiner Intelligence

Grants 54% of resolved cases
54%
Career Allowance Rate
426 granted / 795 resolved
-16.4% vs TC avg
Strong +52% interview lift
Without
With
+51.5%
Interview Lift
resolved cases with interview
Typical timeline
Avg Prosecution
44 currently pending
Career history
841
Total Applications
across all art units

Office Action

§112
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . This action is in response to the RCE filed on 06/08/2026. Continued Examination Under 37 CFR 1.114 A request for continued examination under 37 CFR 1.114, including the fee set forth in 37 CFR 1.17(e), was filed in this application after allowance or after an Office action under Ex Parte Quayle, 25 USPQ 74, 453 O.G. 213 (Comm'r Pat. 1935). Since this application is eligible for continued examination under 37 CFR 1.114, and the fee set forth in 37 CFR 1.17(e) has been timely paid, prosecution in this application has been reopened pursuant to 37 CFR 1.114. Applicant's submission filed on 06/08/2026 has been entered. Claim Rejections - 35 USC § 112 The following is a quotation of 35 U.S.C. 112(b): (b) CONCLUSION.—The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the inventor or a joint inventor regards as the invention. The following is a quotation of 35 U.S.C. 112 (pre-AIA ), second paragraph: The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the applicant regards as his invention. Claim 30 is rejected under 35 U.S.C. 112(b) or 35 U.S.C. 112 (pre-AIA ), second paragraph, as being indefinite for failing to particularly point out and distinctly claim the subject matter which the inventor or a joint inventor (or for applications subject to pre-AIA 35 U.S.C. 112, the applicant), regards as the invention. Claim 30 recites the limitation "the proximal end" in line 4 of the claim. There is insufficient antecedent basis for this limitation in the claim. Claim 30 recites the limitation "the distal end" in line 4 of the claim. There is insufficient antecedent basis for this limitation in the claim. Allowable Subject Matter Claims 22-29 and 31-36 (claims 31-36 were previously rejoined) are allowed. Claim 30 would be allowable if rewritten to overcome the rejection(s) under 35 U.S.C. 112(b) or 35 U.S.C. 112 (pre-AIA ), 2nd paragraph, set forth in this Office action and to include all of the limitations of the base claim and any intervening claims. The following is an examiner’s statement of reasons for allowance: the prior art fails to teach or render obvious an ultrasonic electromechanical system for an ultrasonic instrument, the ultrasonic electromechanical system comprising, inter alia, a control circuit configured to: determine a position of a tissue clamped between the ultrasonic blade and the clamp arm; and control a voltage of the drive signal power applied to the ultrasonic transducer based at least in part on the position of the tissue. Each of the closest prior art of record, Sheldon, IV et al. (US Pub. No.: 2017/0202605), Wiener et al. (US Pub. No.: 2017/0086910), Houser (US Pub. No.: 2009/0036914), Ross et al. (US Pub. No.: 2013/0331874), and Houser (US Pub. No.: 2017/0189093) discloses an ultrasonic electromechanical system for an ultrasonic surgical instrument, the ultrasonic electromechanical system comprising: an ultrasonic blade; a clamp arm disposed opposite the ultrasonic blade; an ultrasonic transducer acoustically coupled to the ultrasonic blade, the ultrasonic transducer configured to ultrasonically oscillate the ultrasonic blade in response to a drive signal; and a control circuit coupled to the ultrasonic transducer. However, none of Sheldon, IV et al. (US Pub. No.: 2017/0202605), Wiener et al. (US Pub. No.: 2017/0086910), Houser (US Pub. No.: 2009/0036914), Ross et al. (US Pub. No.: 2013/0331874), and Houser (US Pub. No.: 2017/0189093) disclose or render obvious that the control circuit is configured to: determine a position of a tissue clamped between the ultrasonic blade and the clamp arm; and control a voltage of the drive signal power applied to the ultrasonic transducer based at least in part on the position of the tissue. Response to Arguments Applicant’s arguments with respect to claim(s) 30 have been considered but are moot in view of new ground(s) of rejection Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to JING RUI OU whose telephone number is (571)270-5036. The examiner can normally be reached M-F 9:00am -5:00pm. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Jackie Ho can be reached at (571) 272-4696. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /JING RUI OU/Primary Examiner, Art Unit 3771
Read full office action

Prosecution Timeline

Show 7 earlier events
Nov 11, 2025
Request for Continued Examination
Nov 14, 2025
Response after Non-Final Action
Feb 10, 2026
Request for Continued Examination
Mar 01, 2026
Response after Non-Final Action
Jun 08, 2026
Request for Continued Examination
Jun 17, 2026
Response after Non-Final Action
Aug 26, 2026
Non-Final Rejection mailed — §112
Nov 04, 2026
Response Filed

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12788383
MEDICAL DEVICE HAVING EXPANDABLE AND COLLAPSIBLE OCCLUDING MEMBERS FOR TREATMENT OF ATRIAL SEPTAL DEFECTS
3y 11m to grant Granted Nov 10, 2026
Patent 12779182
Balloon Stent
6y 10m to grant Granted Nov 03, 2026
Patent 12778584
VASCULAR ANASTOMOSIS DEVICE
3y 10m to grant Granted Nov 03, 2026
Patent 12778595
HEMOSTATIC DEVICE
3y 1m to grant Granted Nov 03, 2026
Patent 12758228
IMPLANTABLE EMBOLIZATION DEVICE
4y 3m to grant Granted Oct 13, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
54%
Grant Probability
99%
With Interview (+51.5%)
High
PTA Risk
Based on 795 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month