Prosecution Insights
Last updated: November 04, 2026
Application No. 17/236,533

SPACER FOR ENDODONTIC INSTRUMENT

Final Rejection §103
Filed
Apr 21, 2021
Priority
Oct 22, 2018 — DE 10 2018 126 242.6 +1 more
Examiner
TO, HOLLY T
Art Unit
3772
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Eberhard Karls Universitat Tubingen Medizinische Fakultat
OA Round
8 (Final)
48%
Grant Probability
Moderate
9-10
OA Rounds
0m
Est. Remaining
81%
With Interview

Examiner Intelligence

Grants 48% of resolved cases
48%
Career Allowance Rate
58 granted / 122 resolved
-22.5% vs TC avg
Strong +33% interview lift
Without
With
+33.4%
Interview Lift
resolved cases with interview
Typical timeline
3y 1m
Avg Prosecution
36 currently pending
Career history
162
Total Applications
across all art units

Statute-Specific Performance

§101
2.4%
-37.6% vs TC avg
§103
51.0%
+11.0% vs TC avg
§102
19.9%
-20.1% vs TC avg
§112
26.6%
-13.4% vs TC avg
Black line = Tech Center average estimate • Based on career data from 122 resolved cases

Office Action

§103
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Continued Examination Under 37 CFR 1.114 A request for continued examination under 37 CFR 1.114, including the fee set forth in 37 CFR 1.17(e), was filed in this application after final rejection. Since this application is eligible for continued examination under 37 CFR 1.114, and the fee set forth in 37 CFR 1.17(e) has been timely paid, the finality of the previous Office action has been withdrawn pursuant to 37 CFR 1.114. Applicant's submission filed on 3/30/2026 has been entered. Claim Rejections - 35 USC § 103 The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. Claim(s) 1-2, 9-10, 14-15, and 18 is/are rejected under 35 U.S.C. 103 as being unpatentable over Cheng (US 4734035 A) in view of Forrest (US 3911587 A), Chen (US 5154611 A), Zdarsky (US 3964170 A), and Siegel (US 3358826 A). Re. Claim 1, Cheng teaches a spacer (Fig. 5-8; label 30) for an endodontic instrument (Abstract) comprising: a base surface (Annotated Figure A of Fig. 5) having a diameter dG (Annotated Figure A of Fig. 5), a top surface having a diameter dD (Annotated Figure A of Fig. 5), an axis of rotation (see Fig. 5 where the endodontic tool 20 is fitted into), a lateral surface (Annotated Figure A of Fig. 5), a height h (Annotated Figure A of Fig. 5), an opening (33) having a longitudinal axis (see Fig. Fig. 6A which shows it extends longitudinally) for receiving an endodontic instrument (Fig. 5), a cylindrical recess (Fig. 5-8 shows element 32 is fitted in and shows the element is cylindrical and as such the recess would be cylindrical) for receiving a stopper (32) on the base surface (Fig. 5), and wherein the opening extends from the base surface to the top surface (Fig. 6A), wherein the longitudinal axis of the opening is coaxial with the axis of rotation of the spacer (Fig. 6A), wherein the cylindrical recess is coaxial with the opening (Fig. 6A), wherein the base surface is configured to abut a crown of a tooth (Abstract; Fig. 1-2 shows the prior art of applicant’s invention wherein the spacer of Cheng would also have the same function, Fig. 3, such that the file is inserted into the tooth), wherein the spacer is made of a colored material, and wherein a color code of the colored material is indicative of the height of the frustoconical spacer; However, Cheng is silent to the spacer being frustonical and the diameter dD is smaller than the diameter dG of the top surface. Further, Cheng is silent to the spacer is made of a colored material, and wherein a color code of the colored material is indicative of the height of the spacer. In addition, Cheng is silent to the spacer being part of a kit with a device, the device comprising a body which comprises at least one recess holding the frustoconical spacer at least partially in a form- fitting manner, wherein the at least partially form-fitting receptacle is configured in such a way that the frustoconical spacer sits in a clamping engagement in the at least one recess. Lastly Cheng is silent to at least one disk for a fine enlargement of the frustoconical spacer, wherein the at least one disk comprises a height of ≤ 0.5 mm. Forrest teaches a spacer in the same field of endeavor of determining predetermined penetration depths and further discloses a spacer (Annotated Figure B of Fig. 6) with frustoconical shape wherein a base surface has a diameter dD is smaller than the diameter dG (Annotated Figure B of Fig. 6). The shape little to no additional restriction on position or manipulation of the instrument. It would have been obvious to someone skilled in the art before the effective filing date to have the spacer of Cheng to be frustoconical and the diameter dD is smaller than the diameter dG of the top surface as taught by Forrest to allow the spacer little to no additional restriction on position or manipulation of the instrument. Chen teaches a stopper in the same field of endeavor and further discloses the stopper (24b/24c) comprises different colors corresponding to different thickness and heights (Col. 4, lines 23-34; As it teaches that the stopper is provided with a color, it would need to be made of at least one material that is colored) to aid in identifying the sized spacers in a kit and during the operation. Chen further teaches in addition to the stopper, that a disc (24a can be applicable) may be present to provide fine enlargement (Fig. 2 shows that the addition to it provides precise and fine enlargement) to allow the user to have a clearer visual aid on when to stop and to adjust the depth penetration even further. In addition, it disclosed that the heights can be varying heights including 0.5 mm (Col. 4, lines 13-22). It would have been obvious to someone skilled in the art before the effective filing date to have the spacer of Cheng and Forrest to comprise a marker indicating the height as taught by Chen to aid in identifying the sized spacers in a kit and during the operation. It would have been obvious to someone skilled in the art before the effective filing date to have the system of Cheng, Forrest, and Chen to have a disk as taught by Chen to aid in providing a larger visual aid of when the user needs to stop. Further, it would have been obvious to someone skilled in the art before the effective filing date to have the disc of Cheng, Forrest, and Chen to comprise a height of 0.5 mm as taught by Chen as a design choice as it is dependent on the spacer and the user’s needs. It should be noted that the instant disclosure describes the disk height are merely preferable, and does not describe them as contributing any unexpected result to the device as the disk height is dependent on the spacer. Zdarsky teaches a device (Fig. 1-4) providing the spacer (15) comprising a body (1) which comprises at least one recess (8) for holding the spacer (Fig. 3) at least partially in a form-fitting manner (Fig. 3; Col. 3, lines 21-34) wherein the at least partially form-fitting receptacle is configured in such a way that the spacer sits in a clamping engagement in the at least one recess (Col. 3, lines 21-34). The device as such aids in placing the stop in the proper place on the dental instrument. It would have been obvious to someone skilled in the art before the effective filing date to have the spacer of Cheng, Forrest, and Chen to have a device to hold the spacer as taught by Zdarsky to act as a guide in placing the spacer and stopper into place. Siegel teaches a kit including dental tools for root canal treatment (Title; Abstract) comprising a device (18/24) and a spacer (see Fig. 4a, label 40a where what is labeled as “red”, “yellow” and “blue” are the stops which is disclosed to be color coded in Col. 3, lines 34-35) and multiple compartments for receiving different endodontic instruments and tools (Col. 3, lines 54-65). It would have been obvious to someone skilled in the art before the effective filing date to have the spacer and device of Cheng, Forrest, Chen and Zdarsky to be part of a kit as taught by Siegel to create an effective kit for canal treatment and provide easy access to all instruments needed for the procedure. PNG media_image1.png 324 579 media_image1.png Greyscale Annotated Figure A PNG media_image2.png 301 545 media_image2.png Greyscale Annotated Figure B Re. Claim 2, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, wherein Cheng teaches the cylindrical recess for receiving a stopper comprises a volume which corresponds to the volume of a stopper (Fig. 5 shows the stopper is fully inserted into the recess). Re. Claim 9, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, wherein Cheng teaches the spacer is made of a material which is selected from a group consisting of: plastic (Col. 2, lines 61-67 discloses that the hard member can be made of acrylic which is a type of plastic). Re. Claim 10, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1 and Chen further teaches the spacer comprises a marker indicating the height (Col. 4, lines 23-34). It would have been obvious to someone skilled in the art before the effective filing date to have the spacer of Cheng, Forrest, Chen, Zdarsky, and Siegel to comprise a marker indicating the height as taught by Chen to aid in identifying the sized spacers in a kit and during the operation. Re. Claim 14, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, wherein Zdarsky further teaches in the area of the recess (Fig. 1), a slit-shaped (7) opening extending towards the edge of the body is configured in the bottom of the body for receiving an endodontic instrument (Col. 3, lines 26-35). Re. Claim 15, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 14, but are silent to the slit-shaped opening comprises a diameter of ≤ 2.0 mm. The instant disclosure describes the slit-shaped opening diameter ≤ 2.0 mm are merely preferable, and does not describe them as contributing any unexpected result to the device as the slit-shaped is dependent on the endodontic instrument being inserted. As such, these parameters are deemed matters of design choice (lacking in any criticality), and can be obtained through routine experimentation in determining optimum results well within someone skilled in the art. Re. Claim 18, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, wherein Siegel discloses the spacer can be inserted and released from the device only in a lateral direction and not vertically upwards or downwards (The spacer can be removed in a lateral direction by holding the device in a lateral direction through the slit 14 as shown in Fig. 6 as well as in an upwards or downwards direction as shown in Fig. 8 through the opening 34). It would have been obvious to someone skilled in the art before the effective filing date to have the spacer of Cheng, Forrest, Chen, Zdarsky, and Siegel to be inserted and released from the device only in a lateral direction and not vertically upwards or downwards as taught by Siegel as it is a design choice as to the means of removing or inserting the spacer to the device. As such the combination would teach the at least one recess holding the frustoconical spacer at least partially in a form-fitting manner is configured such that the frustoconical spacer can be inserted and released from the device only in a lateral direction and not vertically upwards or downwards. Claim(s) 3-8 is/are rejected under 35 U.S.C. 103 as being unpatentable over Cheng (US 4734035 A) in view of Forrest (US 3911587 A), Chen (US 5154611 A), Zdarsky (US 3964170 A), Siegel (US 3358826 A) and Saffro (US 3781996 A). Re. Claim 3, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, but are silent to the cylindrical recess for receiving a stopper comprises a diameter of 2.0 mm to 5.0 mm. Saffro teaches a spacer (Fig. 2) comprising a cylindrical recess (Fig. 4 shows that where element 134 is fitted into is the cylindrical recess) for receiving a stopper (134) comprises a diameter of 2.0 mm to 5.0 mm (Col. 2, lines 56-59) to allow for a stopper to be present to aid in positioning the tool properly. It would have been obvious to someone skilled in the art before the effective filing date to have the cylindrical recess of Cheng, Forrest, Chen, Zdarsky, and Siegel to have a diameter of 2.0 mm to 5.0 mm as taught by Saffro to allow for a stopper to be present to aid in positioning the tool properly. Re. Claim 4, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, but are silent to the cylindrical recess for receiving a stopper comprises a height which is 0.5 mm to 2.0 mm. Saffro teaches a spacer (Fig. 4) comprising a cylindrical recess (Fig. 4 shows that where element 134 is fitted into is the cylindrical recess) for receiving a stopper (134) comprises a height which is 0.5 to 2.0 mm (Col. 3, lines 54-58 discloses that the height of element 32 which is also the height of the recess in which holds the stopper is 1 mm. It is also disclosed that the entire recess of the spacer would be 2 mm as the total length of the spacer is 2 mm). It would have been obvious to someone skilled in the art before the effective filing date to have the height of the cylindrical recess of Cheng, Forrest, Chen, Zdarsky, and Siegel to be between 0.5 to 2.0 mm as taught by Saffro to allow for a stopper to be present to aid in positioning the tool properly. Re. Claim 5, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, but are silent to the diameter dG is 5.0 mm to 15.0 mm. Saffro teaches a spacer (Fig. 2) in the same field of endeavor and further discloses a base surface (32) having a diameter dG being between 5.0 mm to 15.0 mm (Col. 4, lines 17-21 discloses that the diameter would be 5 mm) to accommodate the file without restricting its movement. It would have been obvious to someone skilled in the art before the effective filing date to have the diameter dG of Cheng, Forrest, Chen, Zdarsky, and Siegel to be between 5.0 mm to 15.0 mm as taught by Saffro to accommodate the file without restricting its movement. Re. Claim 6, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, but are silent to the height h is 0.75 mm to 15 mm. Saffro teaches a spacer (Fig. 4) in the same field of endeavor and further discloses a height h being 0.75 mm to 15 mm (Col. 3, lines 54-58 discloses that the total length of the stop would be 2 mm) where the height of the stop is dependent upon the endodontic procedure based on the limit of penetration needed. It would have been obvious to someone skilled in the art before the effective filing date to have the height of Cheng, Forrest, Chen, Zdarsky, and Siegel to have the height h is 0.75 mm to 15 mm as taught by Saffro as the height of the stop is dependent upon the endodontic procedure based on the limit of penetration needed. Re. Claim 7, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, but are silent to the opening for receiving an endodontic instrument comprises a diameter ≤ 2.0 mm. Saffro teaches a spacer (Fig. 2) in the same field of endeavor and further discloses the opening for receiving an endodontic instrument comprises a diameter ≤ 2.0 mm (Col. 2, lines 56-60) wherein the opening is sized to fit the files currently standardized (Col. 2, lines 56-60). It would have been obvious to someone skilled in the art before the effective filing date to have the opening for receiving an endodontic instrument of Cheng, Forrest, Chen, Zdarsky, and Siegel to have a diameter ≤ 2.0 mm as taught by Saffro to fit the size of files currently standardized. Re. Claim 8, Cheng, Forrest, Chen, Zdarsky, and Siegel teaches the kit of claim 1, but are silent to the diameter dD is from 2.5 mm to 10.0 mm. Saffro teaches a spacer (Fig. 2) in the same field of endeavor and further discloses a top surface (30) having a diameter dD to be between 2.5 mm to 10 mm (Col. 4, lines 17-21 discloses that the diameter would be 3 mm) to accommodate the file without restricting its movement. It would have been obvious to someone skilled in the art before the effective filing date to have the diameter dD of Cheng, Forrest, Chen, Zdarsky, and Siegel to be between 2.5 mm to 10 mm as taught by Saffro to accommodate the file without restricting its movement. Response to Arguments Argument #1: Applicant argues that Cheng does disclose the claimed architecture such as the spacer being frustoconical spacer with a cylindrical recess for receiving a stopper. Applicant argues that Cheng discloses a stop-positioner body with a soft member form where Cheng does not disclose the claimed spacer and stopper configuration. Response #1: Though Fig. 6A presents the stopper at the top surface and Fig. 7A shows the stopper at the central portion of the spacer, it should be noted that Fig. 5 presents the stopper at the base of the spacer on the side in which would abut the tooth. Fig. 5 presents the spacer to be found on the file presenting a configuration during use for filing (Col. 3, lines 5-13). The soft member form is being considered the stopper where the spacer is found to receive such a stopper as shown in Fig. 5. The frustoconical limitation is found to not be taught by Cheng but rather is taught by Forrest. Argument #2: Applicant argues that there an error exchanged with the base and top surfaces. Applicant notes Forrest which shows a top surface with a diameter smaller than bottom diameter BUT does not disclose the functional role of such shape. Further, applicant argues that Forrest does not disclose a cylindrical recess for receiving a stopper on the base surface and other limitations regarding the spacer. Response #2: Applicant’s argument is found to not be persuasive. The argument regarding that the geometry is found to not be disclosed to contribute to the calibration system nor provide a sterile clamping workflow. This particular limitation is found to not be claimed in the claim limitation (specifically the topic of calibration and sterilization). It should be noted that though Forrest does not disclose the function of the shape as that of applicant, it still presents the same structure. Because it is capable of such it meets the structural limitation, it would function as claimed. Further, though Forrest does not assert the motivation explicitly, it is found that it is well known in the art that changing of the shape is a design choice where the functionality is found to be the same. Further, it should be noted that Forrest is solely being used to teach the shape of the base where the other limitations are taught by the other references used above. Argument #3: Applicant argues that Chen does not disclose that the spacer is made out of a colored material. Applicant argues that because the stop element is colored it does itself make the spacer being made of a colored material. Applicant further argues that the disc 24a of Chen does not disclose the present claim feature of a disc for fine enlargement of the frustoconical spacer in the spacer-centered sense. Response #3: Applicant’s argument is found to not be persuasive. Applicant’s argument is found to not be persuasive. It is found that applicant does not claim that the entirety of the spacer is made of a colored material. As such, the limitation can be broadly interpreted that a portion of the spacer can be made by a colored material and would read upon the limitation. In this case, the colored layer would read upon the limitation as it is part of the spacer. Further, it is found that Chen does disclose teaching for the feature of a disc for fine enlargement of the frustoconical spacer in the spacer-centered sense. As it is found that Chen provides teaching of fine enlargement of spacers depending on the needs of the user and are color coded to present such differences. Argument #4: Applicant argues that Zdasrky and Siegel is used to teach the general concept and not the deficiencies of claim 1. Applicant argues the references does not disclose the specific combination to be required by the current claim 1. Response #4: Applicant’s argument is found to not be persuasive as the kit of claim 1 is taught by the combination of Cheng, Forrest, Chen, Zdarsky, and Siegel. Argument #5: Applicant argues that claim 18 is found to not be taught by the current references. Response #4: Applicant’s argument is found to not be persuasive as it is found to be taught by Siegel. Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to HOLLY T TO whose telephone number is (571)272-0719. The examiner can normally be reached Monday - Thursday 6:30 - 4:30. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Edelmira Bosques can be reached at (571) 270-5614. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /HOLLY T. TO/Examiner, Art Unit 3772 /EDELMIRA BOSQUES/Supervisory Patent Examiner, Art Unit 3772
Read full office action

Prosecution Timeline

Show 13 earlier events
Dec 31, 2025
Final Rejection mailed — §103
Mar 30, 2026
Request for Continued Examination
Apr 10, 2026
Response after Non-Final Action
Apr 23, 2026
Non-Final Rejection mailed — §103
Jul 28, 2026
Applicant Interview (Telephonic)
Aug 03, 2026
Examiner Interview Summary
Aug 24, 2026
Response Filed
Nov 02, 2026
Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12727965
METHOD AND APPARATUS FOR DENTAL SURGICAL GUIDE VERIFICATION
5y 4m to grant Granted Sep 08, 2026
Patent 12708497
SALIVA SUCTION DEVICE
3y 2m to grant Granted Aug 18, 2026
Patent 12685386
APPLICATOR UNIT
2y 9m to grant Granted Jul 21, 2026
Patent 12667451
ATMOSPHERIC PRESSURE PLASMA JET DEVICE
5y 4m to grant Granted Jun 30, 2026
Patent 12661212
ELECTRONIC FLOSSING DEVICE COMPRISING DISPOSABLE FLOSSING CARTRIDGE
2y 0m to grant Granted Jun 23, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

9-10
Expected OA Rounds
48%
Grant Probability
81%
With Interview (+33.4%)
3y 1m (~0m remaining)
Median Time to Grant
High
PTA Risk
Based on 122 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month