Prosecution Insights
Last updated: October 25, 2026
Application No. 17/583,100

SLEEVE FOR DELIVERY OF EMBOLIC COIL

Non-Final OA §103
Filed
Jan 24, 2022
Priority
Aug 25, 2015 — provisional 62/209,736 +2 more
Examiner
MCGINNITY, JAMES RYAN
Art Unit
3771
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Endoshape Inc.
OA Round
5 (Non-Final)
60%
Grant Probability
Moderate
5-6
OA Rounds
0m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 60% of resolved cases
60%
Career Allowance Rate
70 granted / 116 resolved
-9.7% vs TC avg
Strong +50% interview lift
Without
With
+49.8%
Interview Lift
resolved cases with interview
Typical timeline
3y 5m
Avg Prosecution
48 currently pending
Career history
169
Total Applications
across all art units

Statute-Specific Performance

§101
0.6%
-39.4% vs TC avg
§103
47.4%
+7.4% vs TC avg
§102
30.5%
-9.5% vs TC avg
§112
19.9%
-20.1% vs TC avg
Black line = Tech Center average estimate • Based on career data from 116 resolved cases

Office Action

§103
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Continued Examination Under 37 CFR 1.114 A request for continued examination under 37 CFR 1.114, including the fee set forth in 37 CFR 1.17(e), was filed in this application after final rejection. Since this application is eligible for continued examination under 37 CFR 1.114, and the fee set forth in 37 CFR 1.17(e) has been timely paid, the finality of the previous Office action has been withdrawn pursuant to 37 CFR 1.114. Applicant's submission filed on August 24th, 2026, has been entered. Response to Amendment The claims filed on August 24th, 2026, have been entered. Claims 1-2, 6, and 8-20 remain pending in the Application. Claims 8-20 were previously withdrawn by the Applicant. Response to Arguments The rejection of claims 1-2 and 6 under 103 over Wallace et al. (U.S. Patent No. 9,060,777) in view of Sharma (Pub. No. 2024/0108392) has been withdrawn in light of Applicant’s amendment made August 24th, 2026; specifically, a connection mechanism connecting the advancement mechanism to the therapeutic device, wherein a proximal end of the therapeutic device includes a receiving feature engaged with the distal linking feature of the pusher wire, wherein the receiving feature and the distal linking feature are positioned on overlapping tabs that extend from the therapeutic device and the advancement mechanism, respectively, and wherein the connection mechanism is maintained together by external pressure from the delivery sleeve while the connection mechanism is within the delivery sleeve and releases the therapeutic device from the advancement mechanism when the connection mechanism exits the delivery sleeve. Applicant’s arguments with respect to claim(s) 1-2 and 6 have been considered but are moot because the new ground of rejection does not rely on any reference applied in the prior rejection of record for any teaching or matter specifically challenged in the argument. Claim Rejections - 35 USC § 103 The text of those sections of Title 35, U.S. Code not included in this action can be found in a prior Office action. Claim(s) 1-2 and 6 is/are rejected under 35 U.S.C. 103 as being unpatentable over Lorenzo (Pub. No. 2019/0008522) in view of Smith et al. (Pub. No. 2016/0199067). Regarding claim 1, Lorenzo discloses an endovascular apparatus (10; FIG. 2) comprising: a delivery sleeve (14) having a longitudinal lumen (15) extending between a proximal end and a distal end (FIG. 2); a therapeutic device (20, 40) housed within and extending substantially an entire length of the delivery sleeve (FIGs. 4 and 6: 40 is very long and will take up the entirety of 14 during deployment); wherein the therapeutic device includes one or more detachable polymer endovascular embolization coils ([0044] 40 is at least one embolic coil); an advancement mechanism (14g) comprising a pusher wire ([0059] 14g is a pusher) having a distal linking feature (96); a connection mechanism (98) connecting the advancement mechanism to the therapeutic device (FIGS. 13-14 and [0059] 98 connects 14g to the occlusion device), wherein a proximal end of the therapeutic device includes a receiving feature ([0059] detachment feature 98 has a connection with 96) engaged with the distal linking feature of the pusher wire ([0059] the connection of 98 links with 96), wherein the receiving feature and the distal linking feature are positioned on overlapping tabs that extend from the therapeutic device and the advancement mechanism, respectively ([0042] 30 has a set of overlapping tabs that hold on to 22 and while this is a separate embodiment, [0059] indicates that the connection between 96 and 98 can be a similar attachment as 30; FIG. 2), and wherein the connection mechanism is maintained together by external pressure from the delivery sleeve while the connection mechanism is within the delivery sleeve (FIG. 2: 30 grabs onto 20 while 30 is within 12) and releases the therapeutic device from the advancement mechanism while the connection mechanism exits the delivery sleeve (FIG. 5: 30 releases 22 when 30 exits 12); and wherein an outside diameter of the delivery sleeve is sufficiently small such that the delivery sleeve is insertable into the catheter (FIG. 2: 14 fits within 12). Lorenzo does not disclose a stop positioned on the proximal end of the delivery sleeve which limits a distance the delivery sleeve is inserted into a catheter, wherein the stop comprises an attachment mechanism to connect a proximal end of the catheter, wherein the attachment is a luer connection that engages an opposing luer connection on the proximal end of the catheter, wherein both an inner surface and an outer surface of the delivery sleeve are composed of a material with a low coefficient of friction. Smith et al. discloses a delivery system (10; FIG. 1) comprising a pair of concentric tubes (16, 18), a stop (20) positioned on the proximal end of the inner sleeve which limits a distance the inner tube is inserted into the outer tube ([0069] 20 is at the proximal end of 16 and 18, and limits the distance 18 can go into 16), wherein the stop comprises an attachment mechanism to connect a proximal end of the outer tube (24, 26), wherein the attachment is a luer connection that engages an opposing luer connection on the proximal end of the outer tube ([0069] 24 and 26 can form a luer connector to link 16 and 18) for the purpose of preventing the inner tube from exiting the outer tube too far in the distal direction, and wherein both an inner surface and an outer surface of the inner tube are composed of a material with a low coefficient of friction ([0086-87] 18 can be made of PTFE or nitinol, while Lorenzo [0047] the delivery tube can be made of nitinol; the present spec [0028] discloses the delivery sleeve is made of PTFE). It would have been obvious to one of ordinary skill in the art before the effective filing date to have modified the delivery sleeve and catheter of Lorenzo to have a stop with a luer connection for the purpose of preventing the inner tube from exiting the outer tube too far in the distal direction, as taught by Smith et al., and to further modify the delivery sleeve to be made of PTFE instead of nitinol because the substitution of one material known in the art for another would have resulted in the predictable result of providing a low-coefficient of friction material. KSR, 550 U.S. 398, 82 USPQ2d 1385 (2007). Regarding claim 2, Lorenzo as modified by Smith et al. further discloses the advancement mechanism is configured to engage the therapeutic device to advance the therapeutic device into a patient (Lorenzo [0059] 14g is used to engage and advance 20 into the aneurysm). Regarding claim 6, Lorenzo as modified by Smith et al. further discloses the therapeutic device extends approximately to the distal end of the delivery sleeve (Lorenzo FIGs. 4 and 6: 40 is very long and will take up the entirety of 14 during deployment). Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to JAMES RYAN MCGINNITY whose telephone number is (571)272-0573. The examiner can normally be reached M-Th 8 am-5:30 pm. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Elizabeth Houston can be reached at 571-272-7134. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /JAMES R MCGINNITY/Examiner, Art Unit 3771
Read full office action

Prosecution Timeline

Show 4 earlier events
Dec 08, 2025
Request for Continued Examination
Dec 22, 2025
Response after Non-Final Action
Jan 09, 2026
Non-Final Rejection mailed — §103
Apr 09, 2026
Response Filed
Apr 30, 2026
Final Rejection mailed — §103
Aug 24, 2026
Request for Continued Examination
Aug 26, 2026
Response after Non-Final Action
Oct 05, 2026
Non-Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12765872
DEVICES AND METHODS FOR THE TREATMENT OF VASCULAR ABNORMALITIES
4y 10m to grant Granted Oct 20, 2026
Patent 12765899
ATRAUMATIC THROMBECTOMY DEVICE
3y 5m to grant Granted Oct 20, 2026
Patent 12758428
Ear Hygienic Implements and Kit
2y 9m to grant Granted Oct 13, 2026
Patent 12758230
ENDOSCOPIC TREATMENT TOOL
3y 0m to grant Granted Oct 13, 2026
Patent 12751735
HYDRO DISSECTION AND SUCTION LAPAROSCOPIC INSTRUMENTS AND METHODS OF USE
2y 12m to grant Granted Oct 06, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

5-6
Expected OA Rounds
60%
Grant Probability
99%
With Interview (+49.8%)
3y 5m (~0m remaining)
Median Time to Grant
High
PTA Risk
Based on 116 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month