Application No. 17/975,147

ABSORBENT ARTICLE AND DEFECATION AND URINATION DETERMINATION METHOD

Non-Final OA §103
Filed
Oct 27, 2022
Priority
Apr 30, 2020 — JP 2020-080498 +1 more
Examiner
RASSAVONG, ERIC
Art Unit
3781
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Unicharm Corporation
OA Round
3 (Non-Final)
71%
Grant Probability
Favorable
3-4
OA Rounds
0m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 71% — above average
71%
Career Allowance Rate
116 granted / 164 resolved
+0.7% vs TC avg
Strong +35% interview lift
Without
With
+35.4%
Interview Lift
resolved cases with interview
Typical timeline
2y 6m
Avg Prosecution
32 currently pending
Career history
224
Total Applications
across all art units

Statute-Specific Performance

§101
0.3%
-39.7% vs TC avg
§103
55.2%
+15.2% vs TC avg
§102
23.5%
-16.5% vs TC avg
§112
14.3%
-25.7% vs TC avg
Black line = Tech Center average estimate • Based on career data from 164 resolved cases

Office Action

§103
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Continued Examination Under 37 CFR 1.114 A request for continued examination under 37 CFR 1.114, including the fee set forth in 37 CFR 1.17(e), was filed in this application after final rejection. Since this application is eligible for continued examination under 37 CFR 1.114, and the fee set forth in 37 CFR 1.17(e) has been timely paid, the finality of the previous Office action has been withdrawn pursuant to 37 CFR 1.114. Applicant's submission filed on 03/16/2026 has been entered. Status of Claims Claims 1 and 5-15 are currently pending. Claims 1 and 5-15 are currently amended. Claims 2-4 and 16-21 were previously cancelled. No new subject matter is added. Response to Arguments Applicant’s arguments, see pg. 8-10, filed 03/16/2026, with respect to the rejection of claim 1 under 103 have been fully considered and are persuasive. The examiner agrees that Doseki alone does not teach applying an alternative current to the electrodes and measuring a resistance value form the electrodes. Therefore, the rejection has been withdrawn. However, upon further consideration, a new grounds of rejection is made in view of Ahong et al. (US 20180333306 A1). Ahong teaches a similar excrement detection device capable of measuring resistance 378 of interior region 296 of absorbent article 16 even if capacitances 302a, 302b between electrodes 290a, 290b and interior region 296 change (see Paragraph [0178]-[0180]; Figure 6). Therefore, Doseki in view of Ahong would read on the limitations of claim 1. Claim Rejections - 35 USC § 103 The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. The factual inquiries for establishing a background for determining obviousness under 35 U.S.C. 103 are summarized as follows: 1. Determining the scope and contents of the prior art. 2. Ascertaining the differences between the prior art and the claims at issue. 3. Resolving the level of ordinary skill in the pertinent art. 4. Considering objective evidence present in the application indicating obviousness or nonobviousness. This application currently names joint inventors. In considering patentability of the claims the examiner presumes that the subject matter of the various claims was commonly owned as of the effective filing date of the claimed invention(s) absent any evidence to the contrary. Applicant is advised of the obligation under 37 CFR 1.56 to point out the inventor and effective filing dates of each claim that was not commonly owned as of the effective filing date of the later invention in order for the examiner to consider the applicability of 35 U.S.C. 102(b)(2)(C) for any potential 35 U.S.C. 102(a)(2) prior art against the later invention. Claims 1, 5-7, and 14-15 are rejected under 35 U.S.C. 103 as being unpatentable by Doseki et al. (JP 2019141190 A, as mapped from translated copy attached), hereinafter referred to as “Doseki” and in view of Ahong et al. (US 20180333306 A1), hereinafter referred to as “Ahong”. Regarding Claim 1, Doseki teaches an excrement detection system (see Abstract) comprising: an absorbent article (absorbent member 10, see Figures 1 and 2) comprising: a liquid-absorbent body (absorbent body 50); a liquid-permeable sheet (top sheet 30) disposed on a skin side (the top sheet 30 comes into contact with the wearer's skin when worn on the wearer, see pg. 4 last paragraph) in a thickness direction of the absorbent article with respect to the liquid-absorbent body (see Figure 2); a liquid-impermeable sheet (back sheet 40) disposed on a non-skin side (disposed on the opposite side of top sheet 30, see Figure 2) in the thickness direction with respect to the liquid- absorbent body (see Figure 2); a pair of skin-side electrodes (second positive electrode 71 and second negative electrode 72) between the liquid- permeable sheet and the liquid-absorbent body (between the top sheet 30 and absorbent body 50, see Figure 2); and a pair of non-skin-side electrodes (first positive electrode 61 and first negative electrode 62) between the liquid- impermeable sheet and the liquid-absorbent body (between the back sheet and absorbent body 50, see Figure 2), wherein in a stretched state of the absorbent article (absorbent article can be stretched when applied), a width direction of the absorbent article intersects the thickness direction (see below), a first space between the pair of non-skin-side electrodes in the width direction is a predetermined distance (the electrodes 61 and 62 are arranged at intervals in the width direction of the absorbing member 10, see pg. 5 paragraph 5; see below), a second space between the pair of skin-side electrodes in the width direction is different from the predetermined distance (the electrodes 71 and 72 are spaced at an interval different from electrodes 61 and 62, see pg. 6 paragraph 2; Figure 2; see below); PNG media_image1.png 372 482 media_image1.png Greyscale a detection device (detection device 90) that is electrically connected to the pair of skin-side electrodes and the pair of non-skin-side electrodes (electrically connected to skin side electrodes 61 and 62 and nonskin electrodes 71-72 via first power generation unit 60 second power generation unit 70, see Figures 1-2), the detection device including a main body (detection circuit 94) that: measures, during a measurement period, for each of the pair of skin-side electrodes and the pair of non-skin-side electrodes, a capacitance value (the electric power generated by the second power generation unit 70 is charged in the capacitor C1 and the capacitor C2. Since the capacitor C2 has a smaller capacitance than the capacitor C1, the potential is likely to rise, see pg. 9 paragraph 1); an information processing apparatus (management device 100) that: detects temporal changes in capacitance values measured for the pair of skin-side electrodes and the pair of non-skin-side electrodes during the measurement period (see pg. 9 paragraphs 5-10), and determines a first amount of change in the capacitance value based on the temporal changes, wherein the first amount is an amount of increase in the capacitance value (see pg. 9 paragraph 1). Doseki teaches all of the limitations as discussed above. However, Doseki does not explicitly disclose applying an alternating current to the pair of skin-side electrodes and the pair of non- skin-side electrodes, and measures, during a measurement period, for each of the pair of skin-side electrodes and the pair of non-skin-side electrodes, a capacitance value, and a resistance value; determines a second amount of change in the resistance value based on the temporal changes and the second amount is an amount of decrease in the resistance value. Ahong teaches an excrement detection system (see Abstract) comprising: an absorbent article (absorbent member 16, see Figures 2B) comprising: a detection device (17) applying an alternating current to a pair of skin-side electrodes and a pair of non- skin-side electrodes (applying alternating current to one or more sensing elements 20, see Paragraph [0171]), and measures, during a measurement period, for each of the pair of skin-side electrodes and the pair of non-skin-side electrodes, a resistance value (capable of measuring resistance 378 of interior region 296 of absorbent article 16 even if capacitances 302a, 302b between electrodes 290a, 290b and interior region 296 change, see Paragraph [0178]-[0180]; Figure 6); determines a second amount of change in the resistance value based on the temporal changes and the second amount is an amount of decrease in the resistance value (as moisture is added, resistance 378 of impedance 292 of interior region 296 of absorbent article 16 may decrease see Paragraph [0180]). Doseki and Ahong are analogous art because both teach a an excrement detecting system. It would have been obvious to a person having ordinary skill in the art before the effective filling date of the invention to modify the detection device of Doseki and further include applying an alternating current to the pair of skin-side electrodes and the pair of non- skin-side electrodes, and measures, during a measurement period, for each of the pair of skin-side electrodes and the pair of non-skin-side electrodes, a capacitance value, and a resistance value; determining a second amount of change in the resistance value based on the temporal changes and the second amount is an amount of decrease in the resistance value, as taught by Ahong. Ahong teaches the detection system including applying alternating current and measuring a resistance value is beneficial for allowing one or more complex impedance sensing elements for detecting and/or monitoring both the resistive and capacitive components (see Paragraph [0171]) and once the impedance between a pair or multiple pairs of electrodes have been measured, moisture in absorbent article 16 may be characterized using various algorithms to determine properties including, for example, saturation percentage, estimated fluid volume, and/or enuresis events (see Paragraph [0208]). Doseki and Ahong teach all of the limitations as discussed above and Doseki further teaches when moisture reaches between the pair of skin-side electrodes, the amount of increase in the capacitance value between the pair of skin-side electrodes and the amount of decrease in the resistance value between the pair of skin-side electrodes are relatively suppressed with respect to those between the pair of non-skin-side electrodes (the second power generation unit 70, comprising electrodes 71-72, has lower urination detection sensitivity than the first power generation unit 60 comprising electrodes 61-62, see pg. 6 paragraph 3). However, Doseki and Ahong do not explicitly disclose wherein the second space between the at least one pair of the skin-side electrodes in the width direction is larger than the first space between the at least one pair of the non-skin-side electrodes in the width direction. It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to rearrange the skin side electrodes to be located in the width direction larger than a space between the at least one pair of the non-skin-side electrodes in the width direction, since the claims to electrodes which read on the prior art expect with regard to the position of the electrodes would not have modified the operation of the device (detecting urine or feces). The particular placement of the electrodes would be obvious matter of design choice to one skilled in the art. See In re Japikse, 181 F.2d 1019, 86 USPQ 70 (CCPA 1950) (Claims to a hydraulic power press which read on the prior art except with regard to the position of the starting switch were held unpatentable because shifting the position of the starting switch would not have modified the operation of the device.). See In re Kuhle, 526 F.2d 553, 188 USPQ 7 (CCPA 1975) (the particular placement of a contact in a conductivity measuring device was held to be an obvious matter of design choice). Regarding Claim 5, Modified Doseki teaches all of the limitations as discussed above in claim 1. However, Modified Doseki does not explicitly disclose wherein the second space is 40 mm or larger. It would have been obvious to one having ordinary skill in the art before the effective filing date of the claimed invention to cause the device of Modified Doseki to have a second space between the at least one pair of the skin-side electrodes in the width direction is 40 mm or larger since it has been held that “where the only difference between the prior art and the claims was a recitation of relative dimensions of the claimed device and a device having the claimed relative dimensions would not perform differently than the prior art device, the claimed device was not patentably distinct from the prior art device” Gardner v. TEC Syst., Inc., 725 F.2d 1338, 220 USPQ 777 (Fed. Cir. 1984), cert. denied, 469 U.S. 830, 225 SPQ 232 (1984). In the instant case, the device of Doseki would not operate differently with the spacing and since the skin-skin electrodes is intended to reside within the absorbent article with an approximate smallest space of 40 mm the device would function appropriately having the claimed spacing. Further, applicant places no criticality on the range claimed, indicating simply that the spacing “is 40 mm or larger” be within the claimed ranges (specification pp. [0017]). Regarding Claim 6, Modified Doseki teaches all of the limitations as discussed above in claim 1. However, Modified Doseki does not explicitly disclose wherein the first space is 40 mm or larger. It would have been obvious to one having ordinary skill in the art before the effective filing date of the claimed invention to cause the device of Modified Doseki to have the first space between the at least one pair of the non-skin-side electrodes in the width direction is 40 mm or larger since it has been held that “where the only difference between the prior art and the claims was a recitation of relative dimensions of the claimed device and a device having the claimed relative dimensions would not perform differently than the prior art device, the claimed device was not patentably distinct from the prior art device” Gardner v. TEC Syst., Inc., 725 F.2d 1338, 220 USPQ 777 (Fed. Cir. 1984), cert. denied, 469 U.S. 830, 225 SPQ 232 (1984). In the instant case, the device of Modified Doseki would not operate differently with the spacing and since the non-skin-skin electrodes is intended to reside within the absorbent article with an approximate smallest space of 40 mm the device would function appropriately having the claimed spacing. Further, applicant places no criticality on the range claimed, indicating simply that the spacing “is 40 mm or larger” be within the claimed ranges (specification pp. [0019]). Regarding Claim 7, Modified Doseki teaches all of the limitations as discussed above in claim 1 and Doseki further teaches wherein the pair of skin- side electrodes and the pair of non-skin-side electrodes detect presence or absence of excrement (the absorbent member body 20 of the embodiment includes electrodes 61, 62, 71, and 72 for detecting excrement, see pg. 4 paragraph 6). Regarding Claim 14, Modified Doseki teaches all of the limitations as discussed above in claim 1 and Doseki further teaches wherein the liquid-permeable sheet (backsheet 40) is thicker than any of the pair of skin-side electrodes and the pair of non-skin-side electrodes (backsheet 40 is thicker than the electrodes 61,62 and 71,72, see Figure 2). Regarding Claim 15, Modified Doseki teaches all of the limitations as discussed above in claim 1 and Doseki further teaches wherein in a longitudinal direction of the absorbent article (see below), end portions of each of the pair of skin-side electrodes (see below) and each of the pair of non-skin-side electrodes (see below) are disposed outside at least one of a front end and a back end of the liquid-absorbent body (see below), and PNG media_image2.png 590 552 media_image2.png Greyscale the longitudinal direction intersects the thickness direction in a stretched state of the absorbent article (see below). Claims 8-11 are rejected under 35 U.S.C. 103 as being unpatentable over Doseki and Ahong, as applied in claim 1, and further in view of Curran et al. (WO 2019090387 A1), hereinafter referred to as “Curran”. Regarding Claim 8, Modified Doseki teaches all of the limitations as discussed above in claim 1 and Doseki further teaches wherein each of the pair of skin-side electrodes and each of the pair of non-skin-side electrodes comprise: a conductive portion (electrodes 61,62 and 71,72 are conductive to produce power to electric power generation part 60 and second power generation unit 70, see pg. 5 paragraphs 6 and 9). However, Modified Doseki does not explicitly disclose a liquid-impermeable sheet member disposed overlaid on the conductive portion in the thickness direction. Curran teaches an incontinence monitoring system (10, see Abstract) including a plurality of electrodes (110 and 112) on an absorbent article (25, see Figure 2a) and a liquid-impermeable sheet member disposed overlaid on the conductive portion (substrate 111 and 113 overlaid on electrodes 110 and 112, respectively, see Paragraph [0094] and [0099]) in the thickness direction (see Figure 3). Modified Doseki and Curran are analogous art because both teach an incontinence monitoring system including a plurality of electrodes. It would have been obvious to a person having ordinary skill in the art before the effective filling date of the invention to modify the electrodes of Modified Doseki and further include a liquid impermeable sheet member disposed overlaid on the conductive portion, as taught by Curran. Curran teaches water vapor permeating through the outer layer could alter the electrical properties of capacitive sensors printed or attached to the outer layer. To overcome this issue the water impermeable substrate layer can be located under the conductive electrodes (see Paragraph [0109]). Regarding Claim 9, Modified Doseki teaches all of the limitations as discussed above in claim 8 and Curran further teaches wherein each of the pair of skin-side electrodes (110) and each of the pair of non-skin-side electrodes (112) further comprise the liquid-impermeable sheet member (111 and 113). However, Modified Doseki does not explicitly disclose the liquid-impermeable sheet member positioned on an identical side in the thickness direction. It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to rearrange the liquid impermeable sheet member to be located on an identical side in the thickness direction, since the claims to an liquid impermeable sheet which read on the prior art expect with regard to the position of the liquid impermeable sheet would not have modified the operation of the device (protecting the electrodes from interference of fluid). The particular placement of the liquid impermeable sheet would be obvious matter of design choice to one skilled in the art. See In re Japikse, 181 F.2d 1019, 86 USPQ 70 (CCPA 1950) (Claims to a hydraulic power press which read on the prior art except with regard to the position of the starting switch were held unpatentable because shifting the position of the starting switch would not have modified the operation of the device.). See In re Kuhle, 526 F.2d 553, 188 USPQ 7 (CCPA 1975) (the particular placement of a contact in a conductivity measuring device was held to be an obvious matter of design choice). Regarding Claim 10, Modified Doseki teaches all of the limitations as discussed above in claim 8 and Curran further teaches wherein each of the pair of skin-side electrodes and each of the pair of non-skin-side electrodes further comprise the liquid-impermeable sheet member on the non- skin side in the thickness direction (substrate 111 is on the non-skin side and substrate 113 can be placed on the nonskin side, as described in rearrangement of parts claim 9). Regarding Claim 11, Modified Doseki teaches all of the limitations as discussed above in claim 8 and Curran further teaches wherein the liquid-impermeable sheet member is wider than any of the pair of skin- side electrodes and the pair of non-skin-side electrodes (substrate 111 may be designed to be a little wider than, the conductive electrodes 110, either individually or collectively, see Paragraph [0094]; substrate 113 may be either slightly wider than each conductive electrode 112 or slightly wider than the complete set of capacitive electrodes 112, see Paragraph [0109]). Claims 12-13 are rejected under 35 U.S.C. 103 as being unpatentable over Doseki, Ahong, and Curran, as applied to claim 8 above, and further in view of Ying et al. (WO 2018147803 A1), hereinafter referred to as “Ying”. Regarding Claim 12, Modified Doseki teaches all of the limitations as discussed above in claim 8. However, Modified Doseki does not explicitly teach wherein a liquid- impermeable region is disposed in at least a part of each of the pair of skin-side electrodes and the pair of non-skin-side electrodes, on a side in the thickness direction which is opposite to a side where the liquid-impermeable sheet member is disposed. Ying teaches a liquid sensor for a diaper (see Abstract) comprising a liquid- impermeable region (film 502,) is disposed in at least a part of each of the pair of electrodes (disposed next to electrochemical cells 500, see Figure 5), on a side in the thickness direction which is opposite to a side where the liquid-impermeable sheet member is disposed (on the opposite side of substrate 510, see Figure 5). Modified Doseki and Ying are analogous art because all teach an incontinence device with a plurality of electrodes. It would have been obvious to a person having ordinary skill in the art before the effective filling date of the invention to modify the pair of skin-side electrodes and pair of non-skin side electrodes of Modified Doseki and further include a liquid- impermeable region, as taught by Ying. Ying teaches the device is advantageous for ease of production, low cost, high signal-to-noise ratio, and compactness (see Paragraph [0042]). Regarding Claim 13, Modified Doseki teaches all of the limitations as discussed above in claim 12 and Doseki further teaches a longitudinal direction of the absorbent article (see above) and the longitudinal direction intersects the thickness direction in a stretched state of the absorbent article (see above). Ying further teaches an area of the liquid-impermeable region on a front side with respect to a center (area of the film 502 on the front side of electrochemical cell 500, see Figure 5) is larger than an area of the liquid-impermeable region on a back side with respect to the center (film 502 is larger than the area of the insulated substrate 510 on the back side of the electrochemical cells 500, see Figure 5). Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to ERIC RASSAVONG whose telephone number is (408)918-7549. The examiner can normally be reached Monday - Friday 9:00am-5:30pm PT. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Sarah Al-Hashimi can be reached at (571) 272-7159. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /ERIC RASSAVONG/ (7/16/2026)Examiner, Art Unit 3781 /JESSICA ARBLE/Primary Examiner, Art Unit 3781
Read full office action

Prosecution Timeline

Show 2 earlier events
Jun 17, 2025
Interview Requested
Jun 23, 2025
Applicant Interview (Telephonic)
Jun 23, 2025
Examiner Interview Summary
Aug 07, 2025
Response Filed
Dec 16, 2025
Final Rejection mailed — §103
Mar 16, 2026
Request for Continued Examination
Apr 01, 2026
Response after Non-Final Action
Jul 27, 2026
Non-Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12758699
Abdominal Negative-Pressure Therapy Dressing With Closed-Loop Force Management Control
4y 10m to grant Granted Oct 13, 2026
Patent 12758753
METHOD FOR USING AN ARTICULABLE TENSION CATHETER
1y 12m to grant Granted Oct 13, 2026
Patent 12752076
Catheter Tray, Packaging System, and Associated Methods
3y 4m to grant Granted Oct 06, 2026
Patent 12702538
SYSTEM FOR TREATING EMBOLISM AND ASSOCIATED DEVICES AND METHODS
1y 11m to grant Granted Aug 11, 2026
Patent 12678549
METHOD OF OPERATION UTILIZING ELECTRIC ENERGY FOR PROCESSING OF BLOOD TO NEUTRALIZE PATHOGEN CELLS THEREIN
3y 11m to grant Granted Jul 14, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
71%
Grant Probability
99%
With Interview (+35.4%)
2y 6m (~0m remaining)
Median Time to Grant
High
PTA Risk
Based on 164 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month