Prosecution Insights
Last updated: October 21, 2026
Application No. 18/538,085

TUBE SET WITH DUAL PRESSURE REGULATING VALVE

Non-Final OA §102§103
Filed
Dec 13, 2023
Priority
Dec 13, 2022 — provisional 63/387,172
Examiner
WILLIAMS, PATRICK C
Art Unit
1799
Tech Center
1700 — Chemical & Materials Engineering
Assignee
Rapid Micro Biosystems Inc.
OA Round
1 (Non-Final)
81%
Grant Probability
Favorable
1-2
OA Rounds
0m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 81% — above average
81%
Career Allowance Rate
426 granted / 528 resolved
+15.7% vs TC avg
Strong +25% interview lift
Without
With
+25.2%
Interview Lift
resolved cases with interview
Fast prosecutor
2y 1m
Avg Prosecution
16 currently pending
Career history
547
Total Applications
across all art units

Statute-Specific Performance

§101
0.5%
-39.5% vs TC avg
§103
44.2%
+4.2% vs TC avg
§102
32.1%
-7.9% vs TC avg
§112
20.5%
-19.5% vs TC avg
Black line = Tech Center average estimate • Based on career data from 528 resolved cases

Office Action

§102 §103
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Information Disclosure Statement The information disclosure statement (IDS) is in compliance with the provisions of 37 CFR 1.97. Accordingly, the information disclosure statement is being considered by the examiner. Election/Restrictions Applicant’s election without traverse of Group I in the reply filed on 8/18/2026 is acknowledged. Accordingly, non-elected claims 7-14 are withdrawn. Claim Rejections - 35 USC § 102 The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale, or otherwise available to the public before the effective filing date of the claimed invention. Claim(s) 1, 2, and 5 is/are rejected under 35 U.S.C. 102(a)(1) as being anticipated by applicant’s cited Paullier et al (US 20170096629). Regarding claim 1, Paullier (FIGs 5, 13-14) discloses “A method comprising: filling at least one cassette (100) with sample fluid (from 340, via opening 334); increasing pressure in the at least one cassette (as 320 is a pump, the pressure in 100 would increase with opening 334); reducing the pressure in the at least one cassette (pressure control in paragraphs 181-183 seen to necessarily include reducing pressure, as 220, 320 only increase pressure such that 233, 333 would offset that increase); filling the cassette with media fluid (from 240, via opening 234); and increasing the pressure in the at least one cassette (as 220 is a pump, the pressure in 100 would increase with opening 234).” Regarding claim 2, Paullier (FIGs 13-14) discloses “wherein the cassette comprising an upper chamber (120), a lower chamber (110), and a membrane (130) disposed between the upper and lower chambers, the method comprising: filling the upper chamber of the at least one cassette with the sample fluid (from 340, via opening 334); and increasing pressure in the upper chamber of the at least one cassette (as 320 is a pump, the pressure in 100 would increase with opening 334) to force the sample fluid through the membrane into the lower chamber (during “transmembrane flow” in paragraphs 187-188).” Regarding claim 5, Paullier (FIGs 13-14) discloses “comprising: filling the lower chamber of the at least one cassette with the media fluid (from 240), the media fluid being a solid, liquid (evidenced by 220 being a liquid pump in paragraph 154), gel, gas, or aerosol; and increasing the pressure in the lower chamber of the at least one cassette to force the media fluid to interact with the membrane (during upward filtering of fluid in analogous paragraph 160).” Claim Rejections - 35 USC § 103 The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. Claim(s) 6 is/are rejected under 35 U.S.C. 103 as being unpatentable over Paullier. Paullier is silent regarding “wherein the pressure in the upper chamber is increased by greater than or equal to 1 pound per square inch (PSI) or by greater than or equal to 4 PSI.” It would have been obvious, before the effective filing date, to modify the pressure change operation of Paullier to be any preferred value, in this case such that “wherein the pressure in the upper chamber is increased by greater than or equal to 1 pound per square inch (PSI) or by greater than or equal to 4 PSI”, as Paullier already discloses pressure increase/decrease of the chambers, and choosing preferred magnitudes of pressure increase/decrease to achieve the same expected result would be within routine skill in the art. Claim(s) 3 and 4 is/are rejected under 35 U.S.C. 103 as being unpatentable over Paullier in view of Dhanvijay (US 20220412851, filed 10/12/2016). Regarding claim 3, Paullier is silent regarding “comprising: filling the upper chamber of the at least one cassette with pre-rinse fluid; and increasing the pressure in the upper chamber of the at least one cassette”, although Paullier does increase/decrease the pressure normally during paragraphs 181-183. However, Dhanvijay teaches it is known in the art of transmembrane cell collection/isolation (analogous to Paullier) to conduct a liquid pre-flush (paragraph 174) (seen to read on filling with pre-rinse liquid) in the system prior to the filtration process in order to reduce or eliminate any peak in pressure differential across the membrane where air is sucked through the membrane, prior to the sample passing through. It would have been obvious, before the effective filing date, to modify the process of Paullier with a preliminary liquid pre-flush step, as taught by Dhanvijay, such that the combination teaches “filling the upper chamber of the at least one cassette with pre-rinse fluid (understood that running pre-flush liquid at the membrane would include the liquid entering the upper chamber); and increasing the pressure in the upper chamber of the at least one cassette (this would happen after Dhanvijay, as pressure is being added later)” to reduce or eliminate any peak in pressure differential across the membrane where air is sucked through the membrane, prior to the sample passing through. Regarding claim 4, Paullier is silent regarding “comprising filling the upper chamber of the at least one cassette with post-rinse fluid; and increasing the pressure in the upper chamber of the at least one cassette”, although Paullier does increase/decrease the pressure normally during paragraphs 181-183. However, Dhanvijay teaches it is known in the art of transmembrane cell collection/isolation (analogous to Paullier) to conduct a collection of the isolated cells via back-flushing a fluid (read on pre-rinse fluid) into the system, and includes a pressure increase (paragraphs 196-199). It would have been obvious, before the effective filing date, to modify the process of Paullier with a back-flushing step, as taught by Dhanvijay, such that the combination teaches “comprising filling the upper chamber of the at least one cassette with post-rinse fluid; and increasing the pressure in the upper chamber of the at least one cassette (understood that running back-flush liquid at the membrane would include the liquid entering the upper chamber)” to collect the isolated cells from the membrane. Conclusion The prior art made of record and not relied upon is considered pertinent to applicant's disclosure. Devices similar to the application are disclosed by Mostowfi et al (US 20140369889) and Mori (US 20080124249). Any inquiry concerning this communication or earlier communications from the examiner should be directed to PATRICK C WILLIAMS whose telephone number is (571)431-0767. The examiner can normally be reached M-F 9:00-5:00 PM. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Kenneth Rinehart can be reached at 571-272-4881. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /PATRICK C WILLIAMS/Primary Examiner, Art Unit 3753
Read full office action

Prosecution Timeline

Dec 13, 2023
Application Filed
Feb 14, 2024
Response after Non-Final Action
Oct 01, 2026
Non-Final Rejection mailed — §102, §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12760523
Downspout to Curb Drainage System
2y 1m to grant Granted Oct 13, 2026
Patent 12759499
AIR SUPPLY DEVICE
1y 9m to grant Granted Oct 13, 2026
Patent 12747860
FURNACE SYSTEM
2y 5m to grant Granted Sep 29, 2026
Patent 12742506
VALVE ASSEMBLY
1y 10m to grant Granted Sep 22, 2026
Patent 12736010
BLEED VALVE ASSEMBLY WITH VALVE SEAL FOR GAS TURBINE ENGINE COMPRESSORS
2y 4m to grant Granted Sep 15, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
81%
Grant Probability
99%
With Interview (+25.2%)
2y 1m (~0m remaining)
Median Time to Grant
Low
PTA Risk
Based on 528 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month