Prosecution Insights
Last updated: October 25, 2026
Application No. 18/580,805

MAGNESIUM MESH WITH FEATURES DESIGNED TO BIOABSORB PROGRESSIVELY TO IMPROVE DENTAL BONE REGENERATION

Final Rejection §102
Filed
Jan 19, 2024
Priority
Jul 20, 2021 — provisional 63/223,774 +1 more
Examiner
NELSON, MATTHEW M
Art Unit
3772
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
University of Pittsburgh
OA Round
2 (Final)
58%
Grant Probability
Moderate
3-4
OA Rounds
6m
Est. Remaining
82%
With Interview

Examiner Intelligence

Grants 58% of resolved cases
58%
Career Allowance Rate
510 granted / 881 resolved
-12.1% vs TC avg
Strong +24% interview lift
Without
With
+24.0%
Interview Lift
resolved cases with interview
Typical timeline
3y 3m
Avg Prosecution
48 currently pending
Career history
937
Total Applications
across all art units

Statute-Specific Performance

§101
3.7%
-36.3% vs TC avg
§103
45.4%
+5.4% vs TC avg
§102
21.5%
-18.5% vs TC avg
§112
23.7%
-16.3% vs TC avg
Black line = Tech Center average estimate • Based on career data from 881 resolved cases

Office Action

§102
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Claim Rejections - 35 USC § 102 The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale, or otherwise available to the public before the effective filing date of the claimed invention. Claims 1, 4, 6-11, 13-15, 17 are rejected under 35 U.S.C. 102(a)(1) as being anticipated by Tadic (US 2018/0036127). Tadic shows a dental bone grafting device (Fig. 3, 7-8) comprising a mesh (“mesh-like area 7”), comprising a framework fabricated of a material selected from the group consisting of magnesium metal and a magnesium-based metal alloy ([0068]); and a geometric design formed within the framework (entirety of Fig. 3) comprising a plurality of design features, comprising: two or more fixation point openings (5) each having a corresponding fixation connecting feature corresponding thereto, positioned on a periphery of the framework (body of framework surrounding each 5 at the periphery); and one or more non-fixation point openings (perforations in mesh-like 7; [0074]) each having a corresponding non-fixation connecting feature corresponding thereto, positioned interior to the periphery of the framework (body of framework surrounding each perforation of 7 interior from the periphery), wherein each of the corresponding fixation connecting feature and the corresponding non-fixation connecting feature surrounds and/or connects each of the two or more fixation point openings and the one or more non-fixation point openings, respectively (as seen in Fig. 3), wherein each of the two or more fixation openings and the one or more non-fixation openings, and the corresponding fixation connecting feature and the corresponding non-fixation connecting feature corresponding thereto, respectively, has a corresponding size (each part has a size thereof in 3d space), and wherein each of the corresponding fixation connecting feature has a larger size and a slower corrosion or absorption as compared to the surface area and the corrosion or absorption of each of the corresponding non-fixation connecting feature of the mesh ([0041] and [0051] in particular discuss the implant to be dissolved/bioresorbed and therefore would be of a size to provide such; the smaller size perforations of the interior perforations near 7 in Fig. 3 would lead to faster absorption due to smaller sizes), and wherein the size is selected from surface area, width, and thickness (the features have each of these since they occupy three dimensional space; at least the width and surface area are smaller around perforations interior of the periphery). With respect to claim 4, wherein the surface area of the corresponding fixation connecting feature of the two or more fixation point openings is greater than the surface area of the corresponding non-fixation connecting feature of the non-fixation point openings (as seen in Fig. 3, area around 5 is greater than area around each of the perforations of 7). With respect to claim 6, wherein the two or more fixation point openings are structured to receive a fastening device ([0073]). With respect to claim 7, wherein the fastening device is selected from the group consisting of a bolt and screw (while the fastening device is not positively recited as part of the device, [0073]). With respect to claim 8, wherein the magnesium-based metal alloy, comprises from about 0.85 to about 1.4 weight percent zinc, from about 0.2 to about 0.5 weight percent calcium, from about 0.2 to about 0.5 weight percent manganese, and a balance of magnesium based on a total weight percent of the magnesium- based alloy ([0032] shows the overlap of ranges and in regards to manganese, 0.6 is considered “about 0.5”). With respect to claim 9, wherein the framework is a magnesium foil (Fig. 3, where foil is considered a sheet of magnesium as seen). With respect to claim 10, wherein the magnesium foil has a thickness from about 0.15 mm to about 0.55 mm or a thickness of about 0.35 mm ([0018] 50 and 300 μm is equivalent to 0.05 mm to 0.3 mm, where 0.3 mm is considered “about 0.35 mm”; it is also noted that [0090] states “at least 50 μm”, with an open upper limit, in order to prevent decomposing in too short of a time). With respect to claim 13, wherein the size of the corresponding fixation connecting feature of the two or more fixation point openings is greater at the interface of the fastening device and the magnesium framework as compared to another portion of the two or more fixation point openings (as seen in Fig. 3, particularly the larger portions extending toward the center of the implant away from the opening compared to the smaller portions extending to the perimeter). With respect to claim 14, wherein there are at least two different sizes of the corresponding fixation connecting feature and/or the corresponding non- fixation connecting feature to promote a progressive and/or staged corrosion and/or absorption profile (“two different sizes of the corresponding fixation connecting feature and the corresponding non-fixation connecting feature”: fixation connecting feature surrounding opening 5 is larger size than that of perforations of 7). With respect to claim 15, wherein the device comprises more than two fixation point openings (as sen in Fig. 3). Apparatus claim 17 is rejected similarly to the above since it is simply a broader version of claim 1, particularly with regards to dental use and therefore of a size that could be used for such. Response to Arguments Applicant's arguments filed have been fully considered but they are not persuasive. Applicant argues the newly amended claim language and that Tadic only shows perforations 7 along the periphery, however mesh-like area 7 has many perforations, some along the periphery, but many other towards the interior/middle of Fig. 3). It is these perforations that are being cited in the rejection above. Therefore the periphery around 5 in Fig. 3 will exhibit slower corrosion than the connecting features around individual perforations 7 interior and away from the periphery. Conclusion Applicant's amendment necessitated the new ground(s) of rejection presented in this Office action. Accordingly, THIS ACTION IS MADE FINAL. See MPEP § 706.07(a). Applicant is reminded of the extension of time policy as set forth in 37 CFR 1.136(a). A shortened statutory period for reply to this final action is set to expire THREE MONTHS from the mailing date of this action. In the event a first reply is filed within TWO MONTHS of the mailing date of this final action and the advisory action is not mailed until after the end of the THREE-MONTH shortened statutory period, then the shortened statutory period will expire on the date the advisory action is mailed, and any nonprovisional extension fee (37 CFR 1.17(a)) pursuant to 37 CFR 1.136(a) will be calculated from the mailing date of the advisory action. In no event, however, will the statutory period for reply expire later than SIX MONTHS from the mailing date of this final action. Any inquiry concerning this communication or earlier communications from the examiner should be directed to MATTHEW NELSON whose telephone number is (571)270-5898. The examiner can normally be reached on Monday-Friday 7:30am-5:00pm EDT. If attempts to reach the examiner by telephone are unsuccessful, please contact the examiner’s supervisor, Eric Rosen, at (571) 270-7855. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of an application may be obtained from the Patent Application Information Retrieval (PAIR) system. Status information for published applications may be obtained from either Private PAIR or Public PAIR. Status information for unpublished applications is available through Private PAIR only. For more information about the PAIR system, see http://pair-direct.uspto.gov. Should you have questions on access to the Private PAIR system, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative or access to the automated information system, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /MATTHEW M NELSON/Primary Examiner, Art Unit 3772
Read full office action

Prosecution Timeline

Jan 19, 2024
Application Filed
Mar 19, 2026
Non-Final Rejection mailed — §102
Jun 18, 2026
Response Filed
Oct 01, 2026
Final Rejection mailed — §102 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12758361
Method for Generating Design of Orthodontic Appliance
1y 11m to grant Granted Oct 13, 2026
Patent 12740833
PATIENT SPECIFIC DYNAMIC NAVIGATION TRACKER ARM MOUNT APPARATUS AND METHOD
4y 11m to grant Granted Sep 22, 2026
Patent 12734022
DENTURE BASE AND MANUFACTURING METHOD FOR THE SAME
3y 6m to grant Granted Sep 15, 2026
Patent 12733815
ORAL DIAGNOSTIC DEVICE USING LIGHT
2y 1m to grant Granted Sep 15, 2026
Patent 12727976
ZIRCONIA SURFACE TREATMENT METHOD
1y 10m to grant Granted Sep 08, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
58%
Grant Probability
82%
With Interview (+24.0%)
3y 3m (~6m remaining)
Median Time to Grant
Moderate
PTA Risk
Based on 881 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month