Application No. 18/684,914

INSUFFLATOR SAFETY VALVE HAVING ELECTRICALLY VARIABLE CRACKING PRESSURE

Final Rejection §103§112
Filed
Feb 20, 2024
Priority
Sep 20, 2021 — provisional 63/246,018 +1 more
Examiner
WITTLIFF, KATERINA ANNA
Art Unit
3783
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
ConMed Corporation
OA Round
2 (Final)
35%
Grant Probability
At Risk
3-4
OA Rounds
1y 1m
Est. Remaining
54%
With Interview

Examiner Intelligence

Grants only 35% of cases
35%
Career Allowance Rate
7 granted / 20 resolved
-35.0% vs TC avg
Strong +19% interview lift
Without
With
+18.8%
Interview Lift
resolved cases with interview
Typical timeline
3y 10m
Avg Prosecution
41 currently pending
Career history
76
Total Applications
across all art units

Statute-Specific Performance

§101
1.6%
-38.4% vs TC avg
§103
54.1%
+14.1% vs TC avg
§102
23.0%
-17.0% vs TC avg
§112
19.3%
-20.7% vs TC avg
Black line = Tech Center average estimate • Based on career data from 20 resolved cases

Office Action

§103 §112
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Response to Amendment The Amendments filed 07/24/2026 have been entered. Claims 1, 15 and 17 have thereby been amended. Claims 1-20 are being examined in this office action. Claim Rejections - 35 USC § 112 The following is a quotation of 35 U.S.C. 112(b): (b) CONCLUSION.—The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the inventor or a joint inventor regards as the invention. The following is a quotation of 35 U.S.C. 112 (pre-AIA ), second paragraph: The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the applicant regards as his invention. Claim 14 is rejected under 35 U.S.C. 112(b) or 35 U.S.C. 112 (pre-AIA ), second paragraph, as being indefinite for failing to particularly point out and distinctly claim the subject matter which the inventor or a joint inventor (or for applications subject to pre-AIA 35 U.S.C. 112, the applicant), regards as the invention. Claim 14 recites the limitation "the diaphragm," however, “a diaphragm” was not recited in any preceding claims, but rather “a flexible diaphragm” was recited. “the diaphragm” in claim 14 should be amended to “the flexible diaphragm” for clarity of the structure it claims. There is insufficient antecedent basis for this limitation in the claim. Claim Rejections - 35 USC § 103 The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. The factual inquiries for establishing a background for determining obviousness under 35 U.S.C. 103 are summarized as follows: 1. Determining the scope and contents of the prior art. 2. Ascertaining the differences between the prior art and the claims at issue. 3. Resolving the level of ordinary skill in the pertinent art. 4. Considering objective evidence present in the application indicating obviousness or nonobviousness. This application currently names joint inventors. In considering patentability of the claims the examiner presumes that the subject matter of the various claims was commonly owned as of the effective filing date of the claimed invention(s) absent any evidence to the contrary. Applicant is advised of the obligation under 37 CFR 1.56 to point out the inventor and effective filing dates of each claim that was not commonly owned as of the effective filing date of the later invention in order for the examiner to consider the applicability of 35 U.S.C. 102(b)(2)(C) for any potential 35 U.S.C. 102(a)(2) prior art against the later invention. Claims 1, 2 and 10 are rejected under 35 U.S.C. 103 as being unpatentable over Fischer (US 20210267639) in view of Fischer (US 20210267639) embodiment 29, herein referred to as Fischer’29, in further view of Hill (US 20180134149). Regarding claim 1, Fischer discloses an insufflator for delivering surgical gas from a gas source to a patient's body cavity during a surgical procedure (Fig. 2: full insufflator system), comprising: an electrically variable safety valve (Figs. 7A-B: valves 770 and Figs. 9A-B: valves 970 of the cannula 15 of Fig. 2; para. [0148], second half of paragraph, the solenoid valves being electrically controlled), which is adapted and configured to vent surgical gas from the patient’s body cavity, out of the insufflator and into a surrounding atmosphere to prevent over-pressurization of the patient's body cavity during the surgical procedure when a cracking pressure of the variable safety valve is exceeded (para. [0148], second half of paragraph, para. [0154], last sentence) and wherein a valve member is located between the interior pressure cavity and the vent port (Figs. 7A-B: 770 mechanisms located between opening port 771 and interior cavity 716) and the valve member is operatively associated with a flexible diaphragm that extends across the interior pressure cavity (Fig. 7C: valve with diaphragm 792; para. [0149]). However, although Fischer discloses the remaining limitations, this specific embodiment of Fischer fails to disclose that the venting cannula is integrated into the insufflator itself rather than a separate cannula. Embodiment 29 of Fischer teaches the valve disposed within the insufflator (Fig. 2: cannula 15 is within the insufflator, according to the embodiment of Fig. 29 wherein the venting cannula 22 and cannula 15 are integrated within a single cannula; para. [0103]; para. [0181]) wherein the variable safety valve has an interior pressure cavity that communicates with a gas flow path of the insufflator (Fig. 29: interior space 2916), and the interior pressure cavity communicates with the surrounding atmosphere by way of a vent port (Fig. 29: via filters/vents 2969). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have integrated the teachings of both cannulas being integrated into a single venting cannula attached to the insufflator, as taught by Embodiment 29 of Fischer into the other, general embodiment of Fischer including the valves of Figs 7, in order to create a simpler system with fewer parts, and allow all gas flow and venting to occur in a single cannula. Regarding claim 2, Fischer in view Fischer’29 in further view of Hill teaches an insufflator as recited in claim 1, as described above, but fails to disclose details of the valve actuation comprising a motor. Hill teaches an analogous pressure relief valve mechanism, wherein the variable safety valve (Fig. 1: 43 and 44) includes an electric motor for intra-operatively adjusting the cracking pressure of the variable safety valve (para. [0055], sentence 1). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have modified the valves (770 and 970) of the Fischer system by replacing the binary solenoid actuation with a more variable stepper motor actuation, as taught by Hill, in order to achieve greater control over the degree of pressure relief (Hill: para. [0057], sentences 6-7). Regarding claim 10, Fischer in view of Fischer’29 in further view of Hill teaches an insufflator as recited in claim 1, as described above, further comprising a control valve for controlling the delivery of surgical gas from the insufflator to the patient's body cavity (Fischer: 21; para. [0125], last three sentences). Claims 3-9 and 15-20 are rejected under 35 U.S.C. 103 as being unpatentable over Fischer (US 20210267639) in view of Fischer (US 20210267639) embodiment 29, herein referred to as Fischer’29, in further view of Hill (US 20180134149) in further view of Barnes (US 20210178110). Regarding claim 3, Fischer in view of Fischer’29 in further view of Hill teaches an insufflator as recited in claim 2, as described above, further comprising a motor controller for commanding the electric motor (Fischer: para. [0148], sentences 7-8; Hill: controller 50 of valves 43/44; para. [0057], last two sentences), however. Fischer in view of Hill fails to explicitly teach the controller adjusting the cracking pressure of the valve based on feedback. Barnes teaches an analogous system with a pressure relief valve (Fig. 1: pressure relief valve 100) with a controller (para. [0451], last two sentences) to adjust the cracking pressure of the variable safety valve based upon a feedback signal (para. [0421], last two sentences; para. [0451], last two sentences). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have modified the variable pressure relief valve of the Fischer-Hill combination by incorporating the real-time adjustment of the valve’s cracking pressure based on sensor data from the system, as taught by Barnes, in order to reduce pressure drops to maintain safe inflation in the patient (Barnes: paras. [0334] and [0317]). Regarding claim 4, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 3, as described above, wherein the feedback signal is provided by an input signal from an operator (Barnes: para. [0407], 157 being user adjustable; para. [0371], sentence 5, the length of 157 being directly related to the increase/decrease in the threshold of the pressure relief valve; or, alternatively, para. [0320], adjusting the threshold based off of user adjustment of the area of the outlets). Regarding claim 5, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 3, as described above, wherein the feedback signal is provided by a signal from a sensor (Barnes: paras. [0451] and [0161]-[0164]). Regarding claim 6, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 4, as described above, wherein the motor controller commands the electric motor to adjust the cracking pressure of the variable safety valve based on an operator selected cracking pressure selected from a set of at least two discrete cracking pressure set points (Barnes: para. [0321], the binary of the removable covers creating discrete pressure set points that can be selected between based on how many covers are removed by the user). Regarding claim 7, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 5, as described above, wherein the motor controller commands the electric motor to adjust cracking pressure of the variable safety valve based upon a feedback signal from a flow sensor and/or a pressure sensor (Barnes: para. [0161], based on flow rate sensor feedback; 150 pressure sensing mechanism, para. [0364], sentence 2, based on pressure sensor feedback). Regarding claim 8, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 7, as described above, further comprising a flow sensor for monitoring a flow rate of the surgical gas delivered to the patient's body cavity (Barnes: para. [0161]). Regarding claim 9, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 7, as described above, further comprising a pressure sensor for monitoring the pressure of the surgical gas delivered to the patient's body cavity (Barnes: 150 pressure sensing mechanism, para. [0364], sentence 2). Regarding claim 15, Fischer discloses an insufflator for delivering surgical gas from a gas source to a patient's body cavity during a surgical procedure (Fig. 2: full insufflator system), comprising: an electrically variable safety valve (Figs. 7A-B: valves 770 and Figs. 9A-B: valves 970 of the cannula 15 of Fig. 2; para. [0148], second half of paragraph, the solenoid valves being electrically controlled), which is adapted and configured to vent surgical gas from the patient’s body cavity, out of the insufflator and into a surrounding atmosphere to prevent over-pressurization of the patient's body cavity during the surgical procedure when a cracking pressure of the variable safety valve is exceeded (para. [0148], second half of paragraph, para. [0154], last sentence) and wherein a valve member is located between the interior pressure cavity and the vent port (Figs. 7A-B: 770 mechanisms located between opening port 771 and interior cavity 716) and the valve member is operatively associated with a flexible diaphragm that extends across the interior pressure cavity (Fig. 7C: valve with diaphragm 792; para. [0149]). However, although Fischer discloses the remaining limitations, this specific embodiment of Fischer fails to disclose that the venting cannula is integrated into the insufflator itself rather than a separate cannula. Embodiment 29 of Fischer teaches the valve disposed within the insufflator (Fig. 2: cannula 15 is within the insufflator, according to the embodiment of Fig. 29 wherein the venting cannula 22 and cannula 15 are integrated within a single cannula; para. [0103]; para. [0181]) wherein the variable safety valve has an interior pressure cavity that communicates with a gas flow path of the insufflator (Fig. 29: interior space 2916), and the interior pressure cavity communicates with the surrounding atmosphere by way of a vent port (Fig. 29: via filters/vents 2969). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have integrated the teachings of both cannulas being integrated into a single venting cannula attached to the insufflator, as taught by Embodiment 29 of Fischer into the other, general embodiment of Fischer including the valves of Figs 7, in order to create a simpler system with fewer parts, and allow all gas flow and venting to occur in a single cannula. However, this Fischer combination fails to disclose details of the valve actuation comprising a motor. Hill teaches an analogous pressure relief valve mechanism, comprising b) an electric motor for intra-operatively adjusting the cracking pressure of the variable safety valve (para. [0055], sentence 1, valves 43 and 44); and c) a motor controller for commanding the electric motor to adjust the variable safety valve (controller 50 of valves 43/44; para. [0057], last two sentences). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have modified the valves (770 and 970) of the Fischer system by replacing the binary solenoid actuation with a more variable stepper motor actuation, as taught by Hill, in order to achieve greater control over the degree of pressure relief (Hill: para. [0057], sentences 6-7). However, Fisher in view of Hill fails to explicitly teach that the cracking pressure of the valve is based upon user selection. Barnes teaches an analogous system with a pressure relief valve (Fig. 1: pressure relief valve 100) with a controller (para. [0451], last two sentences) to adjust the cracking pressure of the variable safety valve based upon an operator selected cracking pressure (para. [0407], 157 being user adjustable; para. [0371], sentence 5, the length of 157 being directly related to the increase/decrease in the threshold of the pressure relief valve; or, alternatively, para. [0320], adjusting the threshold based off of user adjustment of the area of the outlets). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have modified the variable pressure relief valve of the Fischer-Hill combination by incorporating the real-time adjustment of the valve’s cracking pressure, as taught by Barnes, in order to reduce pressure drops to maintain safe inflation in the patient (Barnes: paras. [0334] and [0317]). Regarding claim 16, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 15, as described above, wherein the operator selected cracking pressure is selected from a set of at least two discrete cracking pressure set points (Barnes: para. [0321], the binary of the removable covers creating discrete pressure set points that can be selected between based on how many covers are removed by the user). Regarding claim 17, Fischer discloses an insufflator for delivering surgical gas from a gas source to a patient's body cavity during a surgical procedure (Fig. 2: full insufflator system), comprising: an electrically variable safety valve (Figs. 7A-B: valves 770 and Figs. 9A-B: valves 970 of the cannula 15 of Fig. 2; para. [0148], second half of paragraph, the solenoid valves being electrically controlled), which is adapted and configured to vent surgical gas from the patient’s body cavity, out of the insufflator and into a surrounding atmosphere to prevent over-pressurization of the patient's body cavity during the surgical procedure when a cracking pressure of the variable safety valve is exceeded (para. [0148], second half of paragraph, para. [0154], last sentence) and wherein a valve member is located between the interior pressure cavity and the vent port (Figs. 7A-B: 770 mechanisms located between opening port 771 and interior cavity 716) and the valve member is operatively associated with a flexible diaphragm that extends across the interior pressure cavity (Fig. 7C: valve with diaphragm 792; para. [0149]). However, although Fischer discloses the remaining limitations, this specific embodiment of Fischer fails to disclose that the venting cannula is integrated into the insufflator itself rather than a separate cannula. Embodiment 29 of Fischer teaches the valve disposed within the insufflator (Fig. 2: cannula 15 is within the insufflator, according to the embodiment of Fig. 29 wherein the venting cannula 22 and cannula 15 are integrated within a single cannula; para. [0103]; para. [0181]) wherein the variable safety valve has an interior pressure cavity that communicates with a gas flow path of the insufflator (Fig. 29: interior space 2916), and the interior pressure cavity communicates with the surrounding atmosphere by way of a vent port (Fig. 29: via filters/vents 2969). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have integrated the teachings of both cannulas being integrated into a single venting cannula attached to the insufflator, as taught by Embodiment 29 of Fischer into the other, general embodiment of Fischer including the valves of Figs 7, in order to create a simpler system with fewer parts, and allow all gas flow and venting to occur in a single cannula. However, this Fischer combination fails to disclose details of the valve actuation comprising a motor. Hill teaches an analogous pressure relief valve mechanism, comprising b) an electric motor for intra-operatively adjusting the cracking pressure of the variable safety valve (para. [0055], sentence 1, valves 43 and 44); and c) a motor controller for commanding the electric motor to adjust the variable safety valve (controller 50 of valves 43/44; para. [0057], last two sentences). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have modified the valves (770 and 970) of the Fischer system by replacing the binary solenoid actuation with a more variable stepper motor actuation, as taught by Hill, in order to achieve greater control over the degree of pressure relief (Hill: para. [0057], sentences 6-7). However, Fisher in view of Hill fails to explicitly teach that the cracking pressure of the valve is based upon feedback form a sensor. Barnes teaches an analogous system with a pressure relief valve (Fig. 1: pressure relief valve 100) with a controller (para. [0451], last two sentences) to adjust the cracking pressure of the variable safety valve based upon a feedback signal from a sensor (para. [0421], last two sentences; para. [0451], last two sentences). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have modified the variable pressure relief valve of the Fischer-Hill combination by incorporating the real-time adjustment of the valve’s cracking pressure based on sensor data from the system, as taught by Barnes, in order to reduce pressure drops to maintain safe inflation in the patient (Barnes: paras. [0334] and [0317]). Regarding claim 18, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 17, as described above, wherein the feedback signal is generated by a flow sensor and/or a pressure sensor (Barnes: para. [0161], based on flow rate sensor feedback; 150 pressure sensing mechanism, para. [0364], sentence 2, based on pressure sensor feedback). Regarding claim 19, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 18, as described above, further comprising a flow sensor for monitoring a flow rate of the surgical gas delivered to the patient's body cavity (Barnes: para. [0161]). Regarding claim 20, Fischer in view of Fischer’29 in further view of Hill in further view of Barnes teaches an insufflator as recited in claim 18, as described above, further comprising a pressure sensor for monitoring the pressure of the surgical gas delivered to the patient's body cavity (Barnes: 150 pressure sensing mechanism, para. [0364], sentence 2). Claims 12-14 are rejected under 35 U.S.C. 103 as being unpatentable over Fischer (US 20210267639) in view of Fischer (US 20210267639) embodiment 29, herein referred to as Fischer’29, in further view of Hill (US 20180134149) in further view of Creedon (WO 2020249813). Regarding claim 12, Fischer in view of Fischer’29 in further view of Hill teaches an insufflator as recited in claim 2, as described above, wherein the electric motor is a stepper motor (Hill: para. [0055], sentence 1), but fails to explicitly teach the structures of the motorized valve having a lead screw. Creedon teaches an analogous system with a pressure relief valve (Fig. 4: pressure relief valve 50; pg. 16, lines 30-33) that translates rotary motion into linear motion by way of a lead screw (Fig. 4: lead screw 52; pg. 17, lines 3-19). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have modified the stepper motor driven Fischer-Hill valve by incorporating the valve opening/closing structures of the lead screw, as taught by Creedon, such that the motor and controllers taught by Fischer-Hill drive the Creedon lead screw, in order to allow for precise linear movements of the opening/closing force of the valve and greater control of the pressure release rate. Regarding claim 13, Fischer in view of Fischer’29 in further view of Hill in further view of Creedon teaches an insufflator as recited in claim 12, as described above, wherein the lead screw drives a pressure plate in contact with one end of a valve spring (Creedon: Fig. 4: lead screw 52 driving plate 51, spring 38), effectively changing an installed length of the valve spring (Creedon: pg. 17, lines 3-19). Regarding claim 14, Fischer in view of Fischer’29 in further view of Hill in further view of Creedon an insufflator as recited in claim 13, as described above, wherein shortening the installed length of the valve spring linearly correlates with increasing the cracking pressure of the variable safety valve, which permits gas flow when the gas pressure acting against a front face of the diaphragm exceeds a spring force applied to a back side of the diaphragm (Creedon: pg. 17, lines 3-19; the diaphragm being 36 of Fig. 4). Claim 11 is rejected under 35 U.S.C. 103 as being unpatentable over Fischer (US 20210267639) in view of Fischer (US 20210267639) embodiment 29, herein referred to as Fischer’29, in further view of Baier (US 5013294). Regarding claim 11, Fischer in view of Fischer’29 teaches an insufflator as recited in claim 1, as described above, but fails to explicitly disclose a pressure regulator. Baier teaches an analogous insufflator system, further comprising a pressure regulator for controlling the pressure of surgical gas delivered to the insufflator from the gas source (claim 1). It would have been obvious for a person of ordinary skill in the art before the effective filing date of the claimed invention to have modified the Fischer insufflator system by incorporating a pressure regulator, as taught by Baier, in order to ensure the gas source is released at a controlled and safe pressure to avoid damage to the system or harm to the patient. Response to Arguments Applicant’s arguments filed 07/24/2026 have been fully considered and are moot in light of the amendments filed 07/24/2026 and the new grounds of rejection based on those amendments. Applicant argues that Fischer alone, as cited in the previous rejection, fails to teach the variable safety valve disposed within the insufflator. This argument is persuasive based on the teachings of Fischer that the venting/valve features are within venting cannula 22 of Fig. 2, rather than within cannula 15 of Fig. 2. However, Embodiment 29 of Fischer, as relied upon in the new rejections above, teaches that these venting features may be present within the single cannula 15. However, Applicant’s argument that valves 770 are located within the housing of the venting cannula and are therefore not located within the insufflator are not persuasive. Applicant’s own disclosure per Fig. 1 and the specification, teaches Fig. 1 as generally teaching the insufflator system for which all labeled elements are contained within. Given the broadest reasonable interpretation of the claims and the disclosure, the cannula of Fischer is attached to and therefore disposed within the insufflator system, analogous to that of Fig. 1 of the instant application. For these reasons, claims 1-20 stand rejected as recited above, in view of the additional Fischer embodiment. Conclusion THIS ACTION IS MADE FINAL. Applicant is reminded of the extension of time policy as set forth in 37 CFR 1.136(a). A shortened statutory period for reply to this final action is set to expire THREE MONTHS from the mailing date of this action. In the event a first reply is filed within TWO MONTHS of the mailing date of this final action and the advisory action is not mailed until after the end of the THREE-MONTH shortened statutory period, then the shortened statutory period will expire on the date the advisory action is mailed, and any nonprovisional extension fee (37 CFR 1.17(a)) pursuant to 37 CFR 1.136(a) will be calculated from the mailing date of the advisory action. In no event, however, will the statutory period for reply expire later than SIX MONTHS from the mailing date of this final action. Any inquiry concerning this communication or earlier communications from the examiner should be directed to KATERINA ANNA WITTLIFF whose telephone number is (703)756-4772. The examiner can normally be reached M-Th: 9-7ET. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, MICHAEL TSAI can be reached at 571-270-5246. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /K.A.W./Examiner, Art Unit 3783 /NATHAN R PRICE/Primary Examiner, Art Unit 3783
Read full office action

Prosecution Timeline

Feb 20, 2024
Application Filed
Jul 01, 2026
Non-Final Rejection mailed — §103, §112
Jul 24, 2026
Response Filed
Oct 15, 2026
Final Rejection mailed — §103, §112 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12766247
DELIVERY DEVICE FOR DELIVERING A DRUG
4y 1m to grant Granted Oct 20, 2026
Patent 12576240
MICROROBOTS WITH DISTRIBUTED ACTUATION
4y 1m to grant Granted Mar 17, 2026
Patent 12539399
Catheter Assembly Having an Adjustable Side Port Angle and Related Methods
3y 8m to grant Granted Feb 03, 2026
Patent 12508414
SINGLE USE SAFETY CAP FOR USE WITH NEEDLELESS CONNECTORS
3y 11m to grant Granted Dec 30, 2025
Patent 12458756
Stopper for a Medical Injection Device
3y 1m to grant Granted Nov 04, 2025
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
35%
Grant Probability
54%
With Interview (+18.8%)
3y 10m (~1y 1m remaining)
Median Time to Grant
Moderate
PTA Risk
Based on 20 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month