Prosecution Insights
Last updated: November 24, 2026
Application No. 18/692,540

VALVE

Final Rejection §103
Filed
Mar 15, 2024
Priority
Sep 21, 2021 — provisional 63/261,439 +2 more
Examiner
CAHILL, JESSICA MARIE
Art Unit
3753
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Fisher & Paykel Healthcare Limited
OA Round
4 (Final)
79%
Grant Probability
Favorable
5-6
OA Rounds
0m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 79% — above average
79%
Career Allowance Rate
659 granted / 838 resolved
+8.6% vs TC avg
Strong +23% interview lift
Without
With
+22.6%
Interview Lift
resolved cases with interview
Typical timeline
2y 4m
Avg Prosecution
24 currently pending
Career history
870
Total Applications
across all art units

Statute-Specific Performance

§101
0.4%
-39.6% vs TC avg
§103
43.3%
+3.3% vs TC avg
§102
21.0%
-19.0% vs TC avg
§112
34.5%
-5.5% vs TC avg
Black line = Tech Center average estimate • Based on career data from 838 resolved cases

Office Action

§103
DETAILED ACTION Claims 1 and 71-92 were filed with the amendment dated 08/17/2026. Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Response to Arguments Applicant’s arguments, see Remarks, filed 08/17/2026, with respect to the rejection(s) of claim(s) 1 and 71-92 have been fully considered. In view of the claim amendments and arguments, a new ground(s) of rejection is made over WO 2016117830 (“Kim”) in view of U.S. Pat. No. 4,823,828 (“McGinnis”). Applicant argues that Kim does not teach or suggest that the actuator moves until it reaches an equilibrium position where the force exerted on the actuator equals the variable resistance force and wherein the equilibrium position is an open position (see Remarks at pages 8-9). Applicant argues that because Kim operates only at a set pressure and that the valve of Kim is a “relief valve 92”, Kim does not meet the claimed requirements. The examiner respectfully disagrees. The structure of Kim and the application are similar and operate the same in that the actuator is biased closed by the spring, and the actuator opens based on inlet pressure exceeding that of the spring. Kim does operate by moving the actuator to an equilibrium position that is an open position because Kim’s equilibrium position is when the inlet pressure equals a sufficient amount to overcome the spring force and open the actuator and keep the actuator open. With regard to the arguments over claim 86, Applicant contends that Kim fails to teach or suggest that the actuator moves towards or away from the inlet while in the equilibrium position to maintain the pressure of the gases in the chamber within the PEEP range (see Remarks at pages 10-13). The examiner respectfully disagrees. The combination of Kim and McGinnis disclose a device for regulating pressure of gases supplied to a patient where actuator moves until it reaches an equilibrium position where the force exerted on the actuator equals the variable resistance force, with the actuator moving towards or away from the inlet while in the equilibrium position. Kim and McGinnis both disclose pressure regulating valves as they regulate pressure output, and the use of the conical spring of McGinnis in Kim would provide for the actuator moving toward or away from the inlet in the equilibrium position. With regard to arguments over claim 87, Applicant contends that Kim fails to teach or suggest that the equilibrium position is an open position where the actuator is positioned away from the inlet (see Remarks at pages 14-17). In Kim, an equilibrium position can be when the actuator is fully open when the inlet pressure meets the downward pressure from the spring (such as the Fig 12 position). The rejections are maintained and made FINAL. Claim Rejections - 35 USC § 103 In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. This application currently names joint inventors. In considering patentability of the claims the examiner presumes that the subject matter of the various claims was commonly owned as of the effective filing date of the claimed invention(s) absent any evidence to the contrary. Applicant is advised of the obligation under 37 CFR 1.56 to point out the inventor and effective filing dates of each claim that was not commonly owned as of the effective filing date of the later invention in order for the examiner to consider the applicability of 35 U.S.C. 102(b)(2)(C) for any potential 35 U.S.C. 102(a)(2) prior art against the later invention. Claims 1 and 71-92 are rejected under 35 U.S.C. 103 as being unpatentable over WO 2016117830 (“Kim”) in view of U.S. Pat. No. 4,823,828 (“McGinnis”). With regard to claim 1, Kim discloses a valve (90) for use with a respiratory system (Figs 1, 2, 11-14) arranged to convey a breathable gas to a patient (respirator, page 1, lines 5-9), wherein the valve (90) allows gas from within the respiratory system to exit, comprising: a valve body (91a) including an inlet (inlet from 91 towards seat 93, see annotated Figs) and an outlet (gas exits out “H”), said inlet (inlet from 91 towards seat 93, see annotated figs) configured to be in fluid communication with the respiratory system (see Fig 2); an actuator (95) disposed within the valve body (91a), in a flow path between the inlet (inlet from 91 towards seat 93, see annotated Figs) and the outlet (“H”); a biasing member (spring 96), wherein the biasing member (96) is operatively coupled to the actuator (5) (shown in Figs 11-12; 96 contacts 95 and is, therefore, operatively coupled) and the biasing member (96) applies a variable resistance force (variable force based on spring force/constant and based on adjustment of 94 setting pressure of spring) onto the actuator (95) during movement thereof; and an outlet member (94) comprising an orifice (orifice is opening for “H”) for the gas to exit (see Fig 12), the outlet member (94) comprising a supporting member (97a; page 13, lines 39-44) (supporting member 97a is the non-cross-hatched portion shown in Figs 11 and 12; comparing Figs 11 and 12, can see that 95 and hatched portion moves relative to non-hatched 97a portion), wherein the actuator (95) is biased (biased via spring 96) towards the inlet (inlet from 91 towards seat 93) (see Fig 11 position), the actuator (95) configured for movement away from the inlet when aa gas pressure at the inlet exceeds a selected pressure level (position in Fig 12; page 14, lines 5-8), said movement adjusting the flow path between the inlet (inlet from 91 towards seat 93, see annotated Figs) and the outlet (outlet through “H”), to regulate the gas pressure in the respiratory system within a predetermined positive end expiratory pressure (PEEP) range (“set pressure” is considered to be a predetermined positive end expiratory pressure as it is also in a respiratory device; see also page 14, line 14: “set pressure”) wherein the selected pressure level is within the predetermined PEEP range (selected pressure to be set is within a predetermined range), the actuator (95) having an actuator orifice (orifice in middle of 95 through which portion of 97a extends; see annotated Figs) formed therein which accommodates the supporting member (97a) so that the actuator (95) moves along the supporting member (97a) when moving away from the inlet (compare Figs 11 and 12; 95 and connected cross-hatched portion around 97a moves along the non-hatched part that is 97a; Fig 12 shows the difference in location between the closed position and open position; thus the actuator and related components move along 97a); wherein the variable resistance force applied by the biasing member (96) counters a force exerted onto the actuator (95) caused by gas pressure at the inlet (pressure from 91 pushing up on 95 is counter to spring force pushing down, see Fig 11), wherein the actuator (95) moves until it reaches an equilibrium position where the force exerted on the actuator (95) equals the variable resistance force, to substantially maintain gas pressure within the predetermined PEEP range wherein the equilibrium position is an open position (Fig 12 position) where the actuator is positioned away from the inlet to allow the gas to flow along the flow path between the inlet and the outlet (an equilibrium position can be reached if the pressure of the fluid pushing up is the same as that of the spring/biasing member pushing down. In Kim, as pressure pushes up on the variable resistance of the biasing member, an equilibrium position is reached if that pressure matches that of the force of the biasing member. Such as position is shown in Fig 12 with the actuator 95 open. There is not a requirement for permanent or long term equilibrium position being held). PNG media_image1.png 822 723 media_image1.png Greyscale If Kim is not considered to disclose a biasing member that applies a variable resistance force, then McGinnis is relied upon. Kim discloses a biasing member (spring 96) that is variably adjustable (variable force based on spring force/constant and based on adjustment of 94 setting pressure of spring). McGinnis discloses a valve (56) for use with a respiratory system arranged to convey a breathable gas to a patient (see abstract), similar to that of Kim. McGinnis further teaches that the actuator (56) is biased by a biasing member (conical spring 59) that applies a variable resistance force (col. 4, lines 29-41). It would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to utilize a conical spring as taught by McGinnis in place of the spring of Kim, since the springs are known equivalents and the use of which would be known to one of ordinary skill in the art, and because the conical spring of McGinnis provides the benefit of “improved adjustability for threshold resistance settings” (see McGinnis at col. 5, lines 37-39). With regard to claim 71, Kim discloses that the supporting member (97a) for the actuator (95) is configured to guide and stabilize the movement of the actuator (95) (97a guides sliding movement of 95 up and down, compare Figs 11-12; and stabilizes by preventing misalignment of 95). With regard to claim 72, Kim discloses that the actuator (95) comprises a substantially planar lower surface (bottom is planar, see annotated Figs); or the actuator (95) comprises a circular disk (diaphragm would be circular because threaded connections and openings of 94, 91a requires circular shape), wherein the circular disk comprises a substantially planar lower surface (bottom surface is planar, see annotated Figs). With regard to claim 73, Kim discloses all the claimed features with the exception of disclosing a radius of the circular disk (membrane 95) is within a range of 0.2 mm to 3 mm of a radius of the inlet . Kim does disclose that the circular disk (95) would inherently have a radius and that it is a range of the radius of the inlet (inlet from 91 at seat 93) of the valve body (91a). It would have been obvious to one having ordinary skill in the art before the effective filing date of the claimed invention to make the radius of the circular disk within any suitable range of the inlet, such as a range of 0.2 mm to 0.3 mm, since it has been held that where the general conditions of a claim are disclosed in the prior art, discovering the optimum or workable ranges involves only routine skill in the art (see MPEP 2144.05). With regard to claim 74, Kim discloses the actuator (95) has an area greater than a cross sectional area of the inlet (inlet where 91 meets 93) (95 is shown having a greater cross-sectional area of the inlet at the seat 93, see Fig 11). Kim discloses all the claimed features with the exception of disclosing a difference between the area of the actuator and the inlet of the valve body is within a range of 0 to 80mm2, or 1 to 20mm2. Applicant has not disclosed that having a difference between the area of the actuator and the inlet of the valve body is within a range of 0 to 80mm2, or 1 to 20mm2 solves any stated problem or is for any particular purpose. Moreover, it appears that the actuator/valve would perform equally well with having any suitable difference in area between the actuator and inlet. Accordingly, it would have been a matter of obvious design choice to one having ordinary skill in the art before the effective filing date of the claimed invention to make the difference of area between the actuator and inlet be any suitable size, such as within a range of 0 to 80mm2, or 1 to 20mm2 because the difference in area does not appear to provide any unexpected results. With regard to claim 75, Kim (as modified by McGinnis) discloses that the biasing member is a spring (spring 96 in Kim; spring 59 in McGinnis). With regard to claim 76, Kim (as modified by McGinnis) discloses that the variable resistance force applied onto the actuator (95) by the biasing member (spring 59 of McGinnis) is at least partially dependent on: a spring constant (spring 59inherently has a spring constant that determines a force applied), compression of a spring, and/or displacement of the actuator from a valve seat, wherein the valve seat (93) is formed by a portion of the valve body (91a, shown in Figs 11-12). With regard to claim 77¸ Kim (as modified by McGinnis) discloses that gas pressure at the inlet (inlet from 91 into seat 93) applies a lifting force (Flift) onto the actuator (95) (pressure from 91 pushes up on actuator 95), in a direction which is opposite to the variable resistance force (force from spring 59 of McGinnis) applied onto the actuator (95) by the biasing member (spring 96 pushes down onto actuator, see Figs 11-12 of Kim; spring 59 of McGinnis pushes down on actuator), wherein the lifting force may be calculated from Flift=P * A actuator, where P = gas pressure at the inlet of the valve body; A actuator = area of the actuator exposed to the gas pressure at the inlet of the valve body (it is inherent that the lifting force is calculated by the gas pressure and area of the actuator 95 exposed through the inlet; inlet is opening at 91 at seat 93). With regard to claim 78, Kim (as modified by McGinnis) discloses that a position of the actuator (95) is determined by a relative relationship of F bias and Flift, wherein F bias is the variable resistance (spring force) force applied onto the actuator (95) by the biasing member (spring 96/spring 59 of McGinnis), and wherein the actuator (95) is displaced from a valve seat (93), wherein the valve seat (93) is formed by a portion of the valve body (91, see Figs 11-12), when Fiift is greater than F bias (inherently in order to push actuator 95 up off seat 93, the lift force (at A) must be greater than spring force pushing down). With regard to claim 79, Kim (as modified by McGinnis) discloses all the claimed features with the exception of disclosing that the spring constant is smaller than 0.05N/mm. Applicant has not disclosed that having the spring constant smaller than 0.05N/mm solves any stated problem or is for any particular purpose. Rather, the specification provides a variety of ranges for the spring constant (para [0250]). Moreover, it appears that the actuator/valve would perform equally well with having any suitable spring constant for the biasing member. Accordingly, it would have been a matter of obvious design choice to one having ordinary skill in the art before the effective filing date of the claimed invention to make the spring constant of Kim/McGinnis be any suitable size, such as smaller than 0.05N/mm because the spring constant does not appear to provide any unexpected results. With regard to claim 80, Kim (as modified by McGinnis) discloses all the claimed features with the exception of disclosing that the spring constant is between 0.005 to 0.02 N/mm. Applicant has not disclosed that having the spring constant between 0.005 to 0.02 N/mm solves any stated problem or is for any particular purpose. Rather, the specification provides a variety of ranges for the spring constant (para [0250]). Moreover, it appears that the actuator/valve would perform equally well with having any suitable spring constant for the biasing member. Accordingly, it would have been a matter of obvious design choice to one having ordinary skill in the art before the effective filing date of the claimed invention to make the spring constant of Kim/McGinnis be any suitable size, such as between 0.005 to 0.02 N/mm because the spring constant does not appear to provide any unexpected results. With regard to claim 81, Kim discloses that the valve (90) is arranged to compensate for pressure variation (opens upon pressure surpassing a pressure threshold). The phrase “for pressure variation caused by unintentional leaks by reducing a gas flow path size through the valve” is a statement of intended use (intended use of an apparatus does not differentiate the apparatus claim from the prior art. See MPEP 2114). With regard to claim 82¸Kim discloses the valve (90) is arranged to compensate for pressure variation (opens upon pressure surpassing a pressure threshold). The phrase “for pressure variation caused by patient's breathing by allowing a variable portion of the gas within the respiratory system to flow through the valve and exit the respiratory system” is a statement of intended use (intended use of an apparatus does not differentiate the apparatus claim from the prior art. See MPEP 2114). Kim does disclose that the valve allows a portion of gas within a respiratory system (page 1, lines 5-10) and allow for flow through the valve (90) and exit the system (through H). With regard to claim 83, Kim discloses that the respiratory system (page 1, lines 6-10) is configured to deliver a flow rate of breathable gas to a patient when delivering respiratory therapy (“patient” page 1, line 7). Kim discloses all the claimed features with the exception of disclosing that the respiratory system is configured to deliver a flow rate of 5 - 15 L/min of the breathable gas. Applicant has not disclosed that having the flow rate of 5 - 15 L/min solves any stated problem or is for any particular purpose. Furthermore, the specification discloses a variety of ranges for the flow rate (see para [0080]). Moreover, it appears that the valve would perform equally well with any flow rate, such as flow rate of 5 - 15 L/min. Accordingly, it would have been a matter of obvious design choice to one having ordinary skill in the art before the effective filing date of the claimed invention to make the flow rate delivered by Kim be 5-15 L/min because the flow rate does not appear to provide any unexpected results. With regard to claim 84, Kim discloses a predetermined PEEP range (see page 14, line 14: “set pressure”). Kim discloses all the claimed features with the exception of disclosing that the predetermined PEEP range is between 5 and 15cm H20 when delivering PEEP. Applicant has not disclosed that having the predetermined PEEP range be between 5 and 15cm H20 solves any stated problem or is for any particular purpose. Furthermore, the specification discloses a variety of ranges (see para [0119]). Accordingly, it would have been a matter of obvious design choice to one having ordinary skill in the art before the effective filing date of the claimed invention to make the predetermined PEEP range of Kim be between 5 and 15cm H20 when delivering PEEP, because the flow rate does not appear to provide any unexpected results. With regard to claim 85, Kim discloses that the valve (90) is configured to be removably attached (removable via threads between 94 and 91a) to a venting orifice (opening in 91a in which 94/95 is connected) of the respiratory system, wherein the venting orifice is provided in a T-piece device (shown in Fig. 2, T-piece generally between inlet 11 and right and left portions of T at 90 and 12. PNG media_image2.png 842 640 media_image2.png Greyscale With regard to claim 86, Kim discloses a device (generally shown in Figs 1-2) for facilitating regulating pressure of gases supplied to a patient (page 1, lines 5-10; page 7, lines 30-35), the device comprising: a housing (10) defining a chamber (91), the housing (10) having an inlet (11; page 7, lines 34-35) configured for connection with a gas flow source (oxygen tank, page 12, line 1) providing a flow of gases to the chamber (91), an outlet (12) configured to direct gases out from the chamber, and a vent (90) comprising an actuator (95) for controlling venting of gases from the chamber (91) through the vent (90); a biasing member (spring 96) which biases the actuator (95) towards a seated position (position in Fig. 11; page 13, lines 42-44) and applies a variable resistance force (variable force based on spring force/constant and based on adjustment of 94 setting pressure of spring) onto the actuator (95) during movement thereof; and an outlet member (94) comprising an orifice (H) for the vented gases to exit (see Fig 12), the outlet member (94) comprising a supporting member (97a) ,wherein the vent (90) and the actuator (95) are mutually adapted so that the actuator (95) has an exposed area which is exposed to the gases in the chamber (bottom side of 95 exposed from seat 93), wherein the biasing member (spring 96) has a spring constant (inherently has spring constant) selected relative to the exposed area of the actuator whereby the actuator (95) remains in the seated position (Fig 11 position) until a pressure of the gases in the chamber (91) exceeds a selected pressure level (page 14, lines 1-14), the actuator (95) having an actuator orifice (opening in 95 through which portion of 97a extends) formed therein which accommodates the supporting member (97a) so that the actuator (95) moves along the supporting member (97a) when moving relative to the seated position (when move towards Fig. 12 position) (compare Figs 11 and 12; 95 and connected cross-hatched portion around 97a moves along the non-hatched part that is 97a; Fig 12 shows the difference in location between the closed position and open position; thus the actuator and related components move along 97a); wherein the variable resistance force applied by the biasing member (96) counters a force exerted onto the actuator (95) caused by gas pressure at the inlet (pressure from 91 pushing up on 95 is counter to spring force pushing down, see Fig 11), wherein the actuator (95) moves until it reaches an equilibrium position where the force exerted on the actuator (95) equals the variable resistance force, to substantially maintain gas pressure within a predetermined positive expiratory pressure (PEEP) range, wherein the actuator moves towards or away from the inlet while in the equilibrium position to maintain the pressure of the gases in the chamber within the PEEP range (an equilibrium position can be reached if the pressure of the fluid pushing up is the same as that of the spring/biasing member pushing down. In Kim, as pressure pushes up on the variable resistance of the biasing member, an equilibrium position is reached if that pressure matches that of the force of the biasing member, such position would be moved away from the inlet. Such as position is shown in Fig 12 with the actuator 95 open. There is not a requirement for permanent or long term equilibrium position being held). If Kim is not considered to disclose a biasing member that applies a variable resistance force, then McGinnis is relied upon. Kim discloses a biasing member (spring 96) that is variably adjustable (variable force based on spring force/constant and based on adjustment of 94 setting pressure of spring). McGinnis discloses a valve (56) for use with a respiratory system arranged to convey a breathable gas to a patient (see abstract), similar to that of Kim. McGinnis further teaches that the actuator (56) is biased by a biasing member (conical spring 59) that applies a variable resistance force (col. 4, lines 29-41). It would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to utilize a conical spring as taught by McGinnis in place of the spring of Kim, since the springs are known equivalents and the use of which would be known to one of ordinary skill in the art, and because the conical spring of McGinnis provides the benefit of “improved adjustability for threshold resistance settings” (see McGinnis at col. 5, lines 37-39). The combination of Kim and McGinnis would provide that the actuator moves towards or away from the inlet while in the equilibrium position to maintain the pressure of the gases in the chamber within the PEEP range based on the pressure at the inlet relative to the spring forces from the conical spring. With regard to claim 87, Kim discloses a pressure regulating device for facilitating regulating pressure of gases supplied to a patient (see Figs 1-2, 11-12) (page 1, lines 5-10; page 7, lines 30-35), the device comprising: a housing (10) defining a chamber (91), the housing (10) comprising an inlet (11) (11; page 7, lines 34-35) couplable with a flow source providing a flow of gases to the chamber (oxygen tank, page 12, line 1), an outlet (12) couplable with a patient interface for supplying gases to the patient from the chamber (page 9, line 35 to page 10, line 3), and a vent (90) comprising an actuator (95) for controlling venting of gases from the chamber (91) through the vent (90) (page 13, lines 30-38); a biasing member (spring 96) which biases the actuator (95) towards a seated position (position in Fig. 11) (page 13, lines 42-44) and applies a variable resistance force (variable force based on spring force/constant and based on adjustment of 94 setting pressure of spring) onto the actuator (95) during movement thereof; whereby the actuator (95) remains in the seated position (on seat 93, Fig. 11) until pressure of the gases in the chamber (91) exceeds a selected pressure level (page 13, lines 5-8, 14, “set pressure”); and an outlet member (94) comprising an orifice (H) for the vented gases to exit (see Fig. 12), the outlet member (94) comprising a supporting member (97a) aligned with a venting axis (“aligned with” because longitudinal axis of 97a is parallel to longitudinal axis of gas flow out of H; see also Fig. 12), the actuator (95) having an actuator orifice (opening within 95 that part of 97a extends through, see Figs 11-12) formed therein which accommodates the supporting member (97a) so that the actuator (95) moves along the supporting member (97a) when moving relative to the seated position (from Fig 11 to Fig 12) (compare Figs 11 and 12; 95 and connected cross-hatched portion around 97a moves along the non-hatched part that is 97a; Fig 12 shows the difference in location between the closed position and open position; thus the actuator and related components move along 97a); wherein the variable resistance force applied by the biasing member (96) counters a force exerted onto the actuator (95) caused by gas pressure at the inlet (pressure from 91 pushing up on 95 is counter to spring force pushing down, see Fig 11), wherein the actuator (95) moves until it reaches an equilibrium position where the force exerted on the actuator (95) equals the variable resistance force, to substantially maintain gas pressure within a predetermined positive expiratory pressure (PEEP) range, wherein the equilibrium position is an open position (Fig 12 position) where the actuator (95) is positioned away from the inlet to allow for the gases to flow along a flow path between the inlet and the outlet (see Fig 12) (an equilibrium position can be reached if the pressure of the fluid pushing up is the same as that of the spring/biasing member pushing down. In Kim, as pressure pushes up on the variable resistance of the biasing member, an equilibrium position is reached if that pressure matches that of the force of the biasing member. Such as position is shown in Fig 12 with the actuator 95 open. There is not a requirement for permanent or long term equilibrium position being held). If Kim is not considered to disclose a biasing member that applies a variable resistance force, then McGinnis is relied upon. Kim discloses a biasing member (spring 96) that is variably adjustable (variable force based on spring force/constant and based on adjustment of 94 setting pressure of spring). McGinnis discloses a valve (56) for use with a respiratory system arranged to convey a breathable gas to a patient (see abstract), similar to that of Kim. McGinnis further teaches that the actuator (56) is biased by a biasing member (conical spring 59) that applies a variable resistance force (col. 4, lines 29-41). It would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to utilize a conical spring as taught by McGinnis in place of the spring of Kim, since the springs are known equivalents and the use of which would be known to one of ordinary skill in the art, and because the conical spring of McGinnis provides the benefit of “improved adjustability for threshold resistance settings” (see McGinnis at col. 5, lines 37-39). With regard to claim 88, Kim (as modified above by McGinnis) discloses that the biasing member (spring 96 Kim/ spring 59 of McGinnis) and the actuator (95) are mutually adapted to maintain the pressure of the gases within a predetermined positive end expiratory pressure (PEEP) range regardless of a flow rate of the gases within a predetermined flow rate range (page 14, lines 12-14: “therefore, the valve disk 95 is operated only at the set pressure”). With regard to claim 89, Kim (as modified by McGinnis above) discloses that the biasing member (spring 96 of Kim/spring 59 of McGinnis) is disposed in a flow path of the vented gases (shown in Fig 12, vented gases pass from 91 to H by passing the spring 96). With regard to claim 90, Kim (as modified by McGinnis above) discloses that the biasing member (spring 96 of Kim/spring 59 of McGinnis) engages the outlet member (94) and the actuator (95) (shown best in Fig 12). With regard to claim 91, Kim (as modified by McGinnis) discloses that when the gas pressure is at or higher than the selected pressure level (level set for spring by adjusting 97) and there is a further increase in gas pressure, the actuator (95) is configured to move away from the inlet (as pressure rises above minimum pressure required to lift spring 96, actuator 95 will continue to raise upwards due to increased force from gas pressure pushing up on spring and actuator). With regard to claim 92, Kim discloses that when the gas pressure is at or higher than a selected pressure level (level set by spring by adjusting 97) and there is a decrease in the gas pressure, the actuator (95) is configured to move toward the inlet (as pressure drops below force of spring, then the actuator 95 moves downward). Conclusion Applicant's amendment necessitated the new ground(s) of rejection presented in this Office action. Accordingly, THIS ACTION IS MADE FINAL. See MPEP § 706.07(a). Applicant is reminded of the extension of time policy as set forth in 37 CFR 1.136(a). A shortened statutory period for reply to this final action is set to expire THREE MONTHS from the mailing date of this action. In the event a first reply is filed within TWO MONTHS of the mailing date of this final action and the advisory action is not mailed until after the end of the THREE-MONTH shortened statutory period, then the shortened statutory period will expire on the date the advisory action is mailed, and any nonprovisional extension fee (37 CFR 1.17(a)) pursuant to 37 CFR 1.136(a) will be calculated from the mailing date of the advisory action. In no event, however, will the statutory period for reply expire later than SIX MONTHS from the mailing date of this final action. Any inquiry concerning this communication or earlier communications from the examiner should be directed to JESSICA CAHILL whose telephone number is (571)270-5219. The examiner can normally be reached Mon-Fri: 6:30 to 3:00. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisors can be reached by phone. Craig Schneider can be reached at 571-272-60073607 or Kenneth Rinehart can be reached at 571-272-4881. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /JESSICA CAHILL/Primary Examiner, Art Unit 3753
Read full office action

Prosecution Timeline

Show 3 earlier events
Nov 20, 2025
Final Rejection mailed — §103
Jan 16, 2026
Response after Non-Final Action
Feb 13, 2026
Request for Continued Examination
Mar 08, 2026
Response after Non-Final Action
Mar 16, 2026
Non-Final Rejection mailed — §103
Aug 06, 2026
Examiner Interview Summary
Aug 17, 2026
Response Filed
Oct 29, 2026
Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12800038
FOUR-WAY VALVE AND DRYER PROVIDED WITH SUCH A FOUR-WAY VALVE
2y 0m to grant Granted Nov 17, 2026
Patent 12781858
Mounting System for a Sealing Apparatus, a Sealing Apparatus, and a Method for Manufacturing such a Sealing Apparatus
2y 1m to grant Granted Nov 03, 2026
Patent 12766912
FLUID-CONTROLLING VALVE ASSEMBLY
2y 0m to grant Granted Oct 20, 2026
Patent 12768290
STEAM VALVE AND POWER GENERATION SYSTEM
1y 8m to grant Granted Oct 20, 2026
Patent 12760810
FLUIDIC DEVICE COMBINING A NON-RETURN VALVE AND A DUAL-FLOW FLOW RESTRICTOR
2y 1m to grant Granted Oct 13, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

5-6
Expected OA Rounds
79%
Grant Probability
99%
With Interview (+22.6%)
2y 4m (~0m remaining)
Median Time to Grant
High
PTA Risk
Based on 838 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month