Prosecution Insights
Last updated: October 25, 2026
Application No. 18/703,958

ELECTRODE BALLOON CATHETER

Non-Final OA §103
Filed
Apr 23, 2024
Priority
Oct 27, 2021 — CN 202111257836.6 +1 more
Examiner
BYRD, BRIGID K
Art Unit
3771
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Shanghai Microport Rotapace Medtech Co. Ltd.
OA Round
3 (Non-Final)
71%
Grant Probability
Favorable
3-4
OA Rounds
3m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 71% — above average
71%
Career Allowance Rate
235 granted / 329 resolved
+1.4% vs TC avg
Strong +46% interview lift
Without
With
+46.4%
Interview Lift
resolved cases with interview
Typical timeline
2y 9m
Avg Prosecution
43 currently pending
Career history
380
Total Applications
across all art units

Statute-Specific Performance

§101
0.5%
-39.5% vs TC avg
§103
38.8%
-1.2% vs TC avg
§102
26.8%
-13.2% vs TC avg
§112
28.5%
-11.5% vs TC avg
Black line = Tech Center average estimate • Based on career data from 329 resolved cases

Office Action

§103
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Continued Examination Under 37 CFR 1.114 A request for continued examination under 37 CFR 1.114, including the fee set forth in 37 CFR 1.17(e), was filed in this application after final rejection. Since this application is eligible for continued examination under 37 CFR 1.114, and the fee set forth in 37 CFR 1.17(e) has been timely paid, the finality of the previous Office action has been withdrawn pursuant to 37 CFR 1.114. Applicant's submission filed on 09/03/2026 has been entered. Response to Amendment This Office Action is a response to applicant’s arguments and amendment filed 08/10/2026. Claims 1, 6-7 and 9 are amended. Claim 3 is cancelled. Claims 1-2 and 4-15 are currently pending. The objection of claim 2 has been withdrawn due to applicant’s amendment. The rejection of claims 6-7 and 9 under 35 U.S.C. 112(b) is withdrawn due to applicant’s amendment. Response to Arguments Applicant’s arguments, see Remarks, filed 08/10/2026, with respect to the rejection(s) of claim(s) 1-2, 4-6, 8-10 and 13-14 under 35 U.S.C. 103 as being unpatentable over Schultheis in view of Nguyen; claim 7 under 35 U.S.C. 103 as being unpatentable over Schultheis in view of Nguyen and Lee; claims 11-12 under 35 U.S.C. 103 as being unpatentable over Schultheis in view of Nguyen and Zhou; and claim 15 under 35 U.S.C. 103 as being unpatentable over Schultheis in view of Nguyen and McGowan, have been fully considered but are not persuasive, in combination with the amendments to the claims. The rejection has been modified, necessitated by applicant’s amendment to the claims. 1) Applicant argues Nguyen discloses the insulating distance between the positive electrode and the negative electrode being fixed, as opposed to variable (Remarks, pgs. 6-8). In response to applicant’s first argument, it is respectfully submitted Nguyen discloses specific regions of the electrodes that are insulated, and specific regions of the electrodes that are not insulated, which is considered to provide a variable distance between the electrodes as discussed below. Nguyen further describes the variable spacing/separation providing an increase or decrease in the likelihood of a spark forming between the electrodes, based on the location of the first and second exposed regions, as well as the surface areas of the first and second exposed regions, which vary relative to each other. The arguments are narrower than the claim limitations, because the claim does not describe how the distance varies, or the insulating distance varying relative to balloon inflation. Therefore, under broadest reasonable interpretation, any variation in distance is considered to meet the claimed limitation. 2) Applicant further argues the additionally cited references fail to disclose the claimed insulating distance (Remarks, pgs. 6-8). In response to applicant’s second argument, it is respectfully submitted the additionally cited references are not relied on to teach the variable insulating distance as discussed below, therefore applicant’s argument is moot. Claim Rejections - 35 USC § 103 The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. The factual inquiries for establishing a background for determining obviousness under 35 U.S.C. 103 are summarized as follows: 1. Determining the scope and contents of the prior art. 2. Ascertaining the differences between the prior art and the claims at issue. 3. Resolving the level of ordinary skill in the pertinent art. 4. Considering objective evidence present in the application indicating obviousness or nonobviousness. This application currently names joint inventors. In considering patentability of the claims the examiner presumes that the subject matter of the various claims was commonly owned as of the effective filing date of the claimed invention(s) absent any evidence to the contrary. Applicant is advised of the obligation under 37 CFR 1.56 to point out the inventor and effective filing dates of each claim that was not commonly owned as of the effective filing date of the later invention in order for the examiner to consider the applicability of 35 U.S.C. 102(b)(2)(C) for any potential 35 U.S.C. 102(a)(2) prior art against the later invention. Claim(s) 1-2, 4-6, 8-10 and 13-14 are rejected under 35 U.S.C. 103 as being unpatentable over Schultheis (US 2023/0310054 A1) in view of Nguyen (US 2017/0135709 A1) (all references previously of record). Regarding claim 1, Schultheis discloses (see abstract; paras. [0039]-[0127]; figs. 1-4) an electrode balloon catheter (fig. 1), comprising: a catheter body (102, para. [0039]); an outer balloon (104b), wherein the outer balloon is disposed at an end of the catheter body (figs. 1-2a) and is configured to store a conductive medium (paras. [0043] and [0060]); an inner balloon (104a), wherein the inner balloon is disposed at the end of the catheter body (figs. 1-2a) and is located inside the outer balloon (figs. 1-2a); and at least one electrode pair (electrode pair of energy guide 122a, para. [0066]) configured to receive high-voltage pulses so as to generate shock waves (para. [0066]), wherein at least one of the at least one electrode pair is disposed on a surface of the inner balloon (para. [0063]), wherein the surface of the inner balloon comprises an inner surface and an outer surface (fig. 1), wherein the outer balloon, when inflated, is configured to fit onto a target object (fits within vessel wall, fig. 1), and wherein the inner balloon is configured to bring the at least one electrode pair closer to or farther away from the target object through an inflation thereof (para. [0068]), wherein the at least one electrode pair can be adjusted in position with respect to the target lesion by modifying a diameter of the inner balloon (diameter considered to be modified via inflation, such that the position of the electrodes would be adjusted, paras. [0063] and [0068]). However, Schultheis fails to disclose the specific polarity of the electrode pairs, wherein the electrode pair comprises a positive electrode and a negative electrode, wherein the positive electrode and the negative electrode are insulated from each other, and wherein an insulating distance between the positive electrode and the negative electrode is variable. Nguyen teaches (para. [0024]; fig. 2a), in the same field of endeavor, an electrode balloon catheter (fig. 1) comprising an electrode pair comprising a positive electrode (204) and a negative electrode (208), wherein the positive electrode and the negative electrode are insulated from each other (paras. [0023]-[0024]), and wherein an insulating distance between the positive electrode and the negative electrode is variable (via spark gap 215, which Nguyen discloses as including a variable distance dependent on which regions of the electrodes are insulated vs. not insulated, considered to include a variable distance because the distance is variable between insulated regions of the electrodes, see also para. [0023] describing different ratios of exposed regions of surface areas between the first and second electrodes, paras. [0022]-[0025], [0031], [0033] and [0035]), for the purpose of providing the appropriate structure to create a reliable plasma arc at the desired initiation location, increasing the likelihood of generating an arc in certain regions while decreasing the likelihood of generating an arc in other regions (paras. [0022], [0024], [0030] and [0033]). It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the electrode pairs of Schultheis to include positive and negative electrodes insulated from each other, wherein the insulating distance is variable, in order to provide the appropriate structure to create a reliable plasma arc at the desired spark gap location by increasing or decreasing the likelihood of the arc to develop in specific regions, based on the suggestions and teachings of Nguyen (paras. [0022], [0024], [0030] and [0033]). Regarding claim 2, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis further discloses wherein at least one of the at least one electrode pair is disposed on the outer surface of the inner balloon (para. [0063]). Regarding claim 4, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis (as modified) further teaches wherein the insulating distance between the positive and negative electrodes is configured within a predetermined range (see ratios of first and second surface areas, paras. [0023] and [0031] of Nguyen). Regarding claim 5, Schultheis (as modified) teaches the electrode balloon catheter according to claim 4. Schultheis (as modified) further teaches wherein the predetermined range is from 0.01 mm to 10 mm (spark gap sizes of .003 and .004 inches, which is ~.08-0.1mm and therefore falls within the claimed range, paras. [0015] and [0031] of Nguyen). Regarding claim 6, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis (as modified) further teaches wherein the electrode pair comprises the positive electrode and the negative electrode (combination considered to further teach the electrode pair of Schultheis comprising the positive and negative electrodes), wherein the positive electrode and the negative electrode are insulated from each other (combination considered to further teach the positive and negative electrodes insulated from each other), and wherein the positive electrode and the negative electrode are flexibly connected (via spark gap 215, considered to be flexibly connected to help maintain flexibility of overall system, paras. [0018], [0024] and [0031] of Nguyen). Regarding claim 8, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis further discloses wherein the at least one electrode pair comprises a plurality of electrode pairs (one or more energy guides 122a, para. [0064]), wherein the plurality of electrode pairs are arranged axially along and circumferentially around the inner balloon that is inflated (para. [0064]; figs. 1-2a). Regarding claim 9, Schultheis (as modified) teaches the electrode balloon catheter according to claim 8. Schultheis (as modified) further teaches wherein each of the plurality of electrode pairs comprises the positive electrode and the negative electrode (combination considered to further teach each of the one or more energy guides 122a of Schultheis comprising the positive and negative electrodes), wherein the positive electrode and the negative electrode of each electrode pair are arranged axially along the inner balloon that is inflated (para. [0064]; figs. 1-2a of Schultheis), wherein the positive and negative electrodes in adjacent electrode pairs of the plurality of electrode pairs are connected by electrical leads (via first and second wires, paras. [0005] and [0018] of Nguyen). Regarding claim 10, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis further discloses wherein the inner balloon is made of a compliant material or a non-compliant material (paras. [0049]-[0052]). Regarding claim 13, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis further discloses wherein an inflated outer balloon has a diameter of 0.75 mm to 30.0 mm (para. [0053]) and an axial length of 3 mm to 300 mm (para. [0055]). Regarding claim 14, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis further discloses wherein an inflated inner balloon has a diameter of 0.5 mm to 29.0 mm (paras. [0053]-[0054]) and an axial length of 3 mm to 300 mm (para. [0055]). Claim(s) 7 is rejected under 35 U.S.C. 103 as being unpatentable over Schultheis in view of Nguyen as applied to claim 1 above, and further in view of Lee (US 2014/0128859 A1). Regarding claim 7, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis (as modified) further teaches wherein the at least one electrode pair comprises two electrodes with opposite polarities which are the positive electrode and the negative electrode (combination considered to further teach two electrodes in electrode pair comprising the positive and negative electrodes). However, Schultheis (as modified) fails to teach wherein each of the two electrodes is formed on the surface of the inner balloon by electroplating or is provided in a form of a flexible circuit. Lee teaches (paras. [0059]-[0071]; figs. 1a-2a), in the same field of endeavor, an electrode balloon catheter (figs. 1a-b) comprising an electrode pair comprising two electrodes with opposite polarities (bipolar electrode pair 3102 and 3104), wherein each electrode is formed on the surface of the balloon by being provided in the form of a flexible circuit (para. [0071), for the purpose of providing a localized field of tissue and enhanced bonding of the electrodes to the balloon, increasing robustness of the device (paras. [0115], [0121] and [0205]). It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the electrode pairs of Schultheis (as modified) to be attached to the inner balloon via a flexible circuit, in order to provide a sensed tissue volume that is localized, and enhanced bonding of the electrodes to the balloon, increasing robustness of the device, based on the suggestions and teachings of Lee (paras. [0115], [0121] and [0205]). Claim(s) 11-12 are rejected under 35 U.S.C. 103 as being unpatentable over Schultheis in view of Nguyen as applied to claim 1 above, and further in view of Zhou (US 2014/0039358 A1). Regarding claim 11, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. Schultheis further discloses wherein the catheter body comprises an inner tube (118, para. [0042]) and an outer tube (110), wherein the inner tube is received in the outer tube and protrudes out of a distal end of the outer tube (fig. 1), wherein: a proximal end of the outer balloon is fixedly attached to the outer tube (secured to shaft 110, para. [0045]); a distal end of the outer balloon is fixedly attached to the inner tube (secured to shaft 118); an outer-balloon fluid supply lumen in communication with the outer balloon is formed between the inner and outer tubes (outer balloon inflation lumen, paras. [0043] and [0047]); and an inner-balloon fluid supply lumen (inflation lumen for inner balloon 104a, para. [0043]). However, Schultheis (as modified) fails to teach wherein each of a proximal end and a distal end of the inner balloon is fixedly attached to the inner tube; and an inner-balloon fluid supply lumen in communication with the inner balloon is provided within the inner tube. Zhou teaches (paras. [0029]-[0053]; figs. 1-4), in the same field of endeavor, an electrode balloon catheter (figs. 1-2) comprising an inner balloon (154, para. [0029]) and an outer balloon (142), wherein each of a proximal end and a distal end of the inner balloon is fixedly attached to an inner tube (attached to 130 and 122 which are coupled together, paras. [0032] and [0043]; fig. 2), and an inner-balloon fluid supply lumen (124, para. [0045]) is in communication with the inner balloon and provided within the inner tube (para. [0043]; fig. 2), for the purpose of delivering different fluids to each of the balloons depending on the desired application of fluid (para. [0033]). It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the device of Schultheis (as modified) to include distinct inflation lumens for the inner balloon and outer balloon formed in the inner and outer tubes, respectively, such that the inner balloon is connected to the inner tube as claimed, in order to provide the capability of delivering different fluids to each of the balloon depending on the desired application of the device, aiding in tracking and/or positioning of the balloon member or reducing the amount of fluid required to inflate the balloons, based on the suggestions and teachings of Zhou (para. [0033]). Regarding claim 12, Schultheis (as modified) teaches the electrode balloon catheter according to claim 11. Schultheis (as modified) further teaches wherein the catheter body further comprises a handle (128, para. [0039] of Schultheis) that is located at a proximal end (fig. 1 of Schultheis), wherein a proximal end of the inner tube and a proximal end of the outer tube are connected to the handle (fig. 1 of Schultheis), wherein the handle is provided with an outer-balloon fluid inlet and an inner-balloon fluid inlet (combination considered to further teach distinct inflation lumens for the inner balloon and the outer balloon, paras. [0044]-[0045] of Zhou), wherein the outer-balloon fluid inlet is connected to the outer-balloon fluid supply lumen, and wherein the inner-balloon fluid inlet is connected to the inner-balloon fluid supply lumen (combination considered to further teach distinct fluid inlets connected to respective outer balloon inflation lumen and inner balloon inflation lumen). Claim(s) 15 is rejected under 35 U.S.C. 103 as being unpatentable over Schultheis in view of Nguyen as applied to claim 1 above, and further in view of McGowan (US 2020/0397453 A1). Regarding claim 15, Schultheis (as modified) teaches the electrode balloon catheter according to claim 1. However, Schultheis (as modified) fails to teach wherein at least one of the at least one electrode pair is disposed on the inner surface of the inner balloon. McGowan teaches (paras. [0061]-[0062]; figs. 2-3), in the same field of endeavor, a balloon catheter (100) comprising a photoacoustic transducer disposed on an inner surface of an inner balloon (disposed on inner surface of balloon 122, which may be surrounded by an outer balloon, para. [0061]), in place of the transducer being disposed on the outer surface of the balloon (para. [0061]). The substitution of one known element (the structure for inducing fractures located on the inner surface of the inner balloon) for another (the structure for inducing fractures located on the outer surface of the inner balloon, para. [0061] of McGowan, para. [0063] of Schultheis) would have been obvious to one of ordinary skill in the art, before the effective filing date of the claimed invention, since the substitution of the electrode pair located on the inner surface of the inner balloon as taught by McGowan, would have yielded predictable results, specifically, inducing fractures in the lesion by providing variations in placement of the electrode pair to treat different areas of tissue. Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to BRIGID K BYRD whose telephone number is (571)272-7698. The examiner can normally be reached Mon-Fri 8:00-5:00. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Darwin Erezo can be reached at (571)-272-4695. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /BRIGID K BYRD/Examiner, Art Unit 3771
Read full office action

Prosecution Timeline

Apr 23, 2024
Application Filed
Oct 21, 2025
Non-Final Rejection mailed — §103
Jan 20, 2026
Response Filed
May 13, 2026
Final Rejection mailed — §103
Aug 10, 2026
Response after Non-Final Action
Sep 03, 2026
Request for Continued Examination
Sep 10, 2026
Response after Non-Final Action
Oct 07, 2026
Non-Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12765911
THROMBECTOMY DEVICE
2y 7m to grant Granted Oct 20, 2026
Patent 12758749
Balloon for Catheter
2y 9m to grant Granted Oct 13, 2026
Patent 12740807
A VALVE MECHANISM
3y 10m to grant Granted Sep 22, 2026
Patent 12714459
PATTERN NEEDLES AND CARTRIDGE FOR TATTOO REMOVAL
2y 6m to grant Granted Aug 25, 2026
Patent 12714452
SURGICAL TUNNELING DEVICES AND METHODS
2y 9m to grant Granted Aug 25, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
71%
Grant Probability
99%
With Interview (+46.4%)
2y 9m (~3m remaining)
Median Time to Grant
High
PTA Risk
Based on 329 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month