DETAILED ACTION
Notice of Pre-AIA or AIA Status
The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA .
In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status.
Claim Rejections - 35 USC § 102
The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action:
A person shall be entitled to a patent unless –
(a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale, or otherwise available to the public before the effective filing date of the claimed invention.
Claim(s) 1 – 3 are rejected under 35 U.S.C. 102 (a)(1) as being anticipated by JP 2021116209 A to Kato et al., hereinafter “Kato”. A machine translation of Kato was included with this action.
Kato is directed to a method of producing silica particles (sol), and a polishing method for producing a semiconductor wafer [0001].
Regarding claims 1 – 2, Kato teaches a colloidal silica material with an average particle diameter of 77 nm and having a CV value of 22.8% (Table 1) translated. A particle CV value stands for the Coefficient of Variation of a particle population. It is a standardized, dimensionless statistical metric used to measure the breadth or uniformity of a particle size distribution. The type of particle distribution, log-normal or gaussian is not known. With an average particle size of 77 nm (0.077 microns) and a CV of 20 – 30% means that there will be virtually negligible to zero amount of coarse particles reaching 0.2 microns (200 nm) or more.
Calculations: For a 20% CV, 1 standard deviation (SD) = 0.2 * 77 nm = 15.4 nm. For a 30% CV, 1 standard deviation (SD) = 0.3 * 77 nm = 23.1 nm. For both of these a 200 nm (0.2 micron) particle is 7.9 and 5.3 SD away from the mean. Therefore, the chance of finding a particle this large is effectively 0% for both a 20% and 30% CV. See Google search notes.
The silica particles obtained by the method of Kato can be used as a polishing composition [0073].
As to claim 3, Kato teaches a process for producing colloidal silica in Example 1 comprising a solution B-1, comprising 100 parts by mass of tetramethoxysilane (TEOS) and 25 parts by mass of methanol (tetramethoxysilane concentration of 80% by mass) into a solution (a-1) obtained by mixing 3.9 parts by mass water, 78.3 parts by mass methanol and 11.2 parts of a 10% by mass ammonia / water. A solution (C-1) comprising 9.1 parts by mass of water and 15.6 parts by mass of a 10% by mass ammonium water solution were mixed and added dropwise to the previous solution (Example 1).
Solution (A-1) comprises 3.9 parts by mass water (3.9 cc water), 78.3 parts by mass methanol (98.9 cc methanol at a density of 0.79 g.cc) and 11.2 parts of a 10% by mass ammonia / water (a volume of 11.7 cc at a density of 0.97 g/cc) relative to 100 g of tetramethoxysilane in the reaction liquid. The ammonia concentration is (11.2 X 0.10)g / (3.0 + 98.9 + 11.7) cc = 9.78 mg / cc = approximately 0.57 mol / L. The reaction liquid comprises 3.9 + 11.2*0.90 + 29.1 + 15.6*0.90 = 57.1 g of water per 100 g of tetramethoxysilane. This corresponds to 4.8 mol of water to 1 mol of tetramethoxysilane. Because solution (B-1) in Example 1 comprises 100 g TEOS (97.1 cc), 25.0g methanol (31.6 cc) the methanol concentration is 25 g / (97.1 + 31.6) cc = 0.19 g/cc = approximately 6.1 mol/L. The values for alkaline catalyst (ammonia), water and alcohol concentration in the alkoxysilane all lie within the claimed ranges.
Conclusion
Any inquiry concerning this communication or earlier communications from the examiner should be directed to PETER A. SALAMON whose telephone number is 571-270-3018. The examiner can normally be reached M-F: 9AM - 6PM.
Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice.
If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Curtis Mayes can be reached at 571-272-1234. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300.
Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000.
PAS 9/28/26
/PETER A SALAMON/Primary Examiner, Art Unit 1759