Prosecution Insights
Last updated: November 22, 2026
Application No. 18/811,048

MEDICAL ROBOTIC SYSTEM WITH COUPLED CONTROL MODES

Non-Final OA §103
Filed
Aug 21, 2024
Priority
Jun 13, 2007 — CIP of 7725214 +8 more
Examiner
BARNES-BULLOCK, CRYSTAL JOY
Art Unit
2117
Tech Center
2100 — Computer Architecture & Software
Assignee
Intuitive Surgical Operations Inc.
OA Round
1 (Non-Final)
86%
Grant Probability
Favorable
1-2
OA Rounds
6m
Est. Remaining
73%
With Interview

Examiner Intelligence

Grants 86% — above average
86%
Career Allowance Rate
588 granted / 686 resolved
+30.7% vs TC avg
Minimal -13% lift
Without
With
+-13.1%
Interview Lift
resolved cases with interview
Typical timeline
2y 9m
Avg Prosecution
11 currently pending
Career history
697
Total Applications
across all art units

Statute-Specific Performance

§101
11.0%
-29.0% vs TC avg
§103
28.0%
-12.0% vs TC avg
§102
32.0%
-8.0% vs TC avg
§112
16.9%
-23.1% vs TC avg
Black line = Tech Center average estimate • Based on career data from 686 resolved cases

Office Action

§103
DETAILED ACTION The following is an initial Office Action upon examination of the above-identified application on the merits. Claims 1-20 are pending in this application. Notice of Pre-AIA or AIA Status The present application is being examined under the pre-AIA first to invent provisions. In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. Priority Applicant’s claim for the benefit of a prior-filed application under 35 U.S.C. 119(e) or under 35 U.S.C. 120, 121, 365(c), or 386(c) is acknowledged. Applicant has not complied with one or more conditions for receiving the benefit of an earlier filing date under 35 U.S.C. 120. Information Disclosure Statement The examiner has considered the information disclosure statements (IDS) submitted on 17 June 2026, 5 February 2026, 14 July 2025, 12 March 2025, 11 February 2025, 11 October 2024 and 28 August 2024. Claim Rejections - 35 USC § 103 The following is a quotation of pre-AIA 35 U.S.C. 103(a) which forms the basis for all obviousness rejections set forth in this Office action: (a) A patent may not be obtained though the invention is not identically disclosed or described as set forth in section 102, if the differences between the subject matter sought to be patented and the prior art are such that the subject matter as a whole would have been obvious at the time the invention was made to a person having ordinary skill in the art to which said subject matter pertains. Patentability shall not be negated by the manner in which the invention was made. Claims 1, 2, 11, and 12 is/are rejected under pre-AIA 35 U.S.C. 103(a) as being unpatentable over US Pub. No. 2003/0013949 A1 (USPN 6,659,939 B2) to Moll et al. in view of US Pub. No. 2007/0013336 A1 (USPN 8,004,229 B2) to Nowlin et al. As per claim 1, the Moll et al. reference discloses a system comprising: a first manipulator (see figure 11, “master manipulator 404”); a second manipulator (see figure 11, “slave manipulator 416”); an input device (see figure 11, “master input controller 406, slave input/output module 414”) for commanding movement (see [0118], “movement”) of the first manipulator (“master manipulator 404”) or the second manipulator (“slave manipulator 416”); and one or more controllers (see figure 11, “master and slave joint controllers 560, 420”); wherein the one or more controllers (“master and slave joint controllers 560, 420”) are configured to: detect movement of the input device (“master input controller 406, slave input/output module 414”); when movement of the first manipulator (“master manipulator 404”) is responsive to movement (see [0070], “in response to movement”) of the input device (“master input controller 406”): determine a commanded movement (“movement”) for the first manipulator (“master manipulator 404”) from the detected movement of the input device (“master input controller 406”); and command the second manipulator (“slave manipulator 416”) to move in response, at least in part, to the commanded movement (“movement”) of the first manipulator (“master manipulator 404”); and when movement of the second manipulator (“slave manipulator 416”) is responsive to the movement of the input device (“slave input/output module 414”): determine a commanded movement (“movement”) for the second manipulator (“slave manipulator 416”) from the detected movement of the input device (“slave input/output module 414”); and command the first manipulator (“master manipulator 404”) to move in response, at least in part, to the commanded movement (“movement”) of the second manipulator (“slave manipulator 416”). The Moll et al. reference does not expressly disclose the further limitations taught by the Nowlin et al. reference, namely: command the second manipulator to move in response, at least in part, to the commanded movement (see [0059], “movement”) of the first manipulator (see [0005], “joints optionally being driven in response to movements of other joints”) and command the first manipulator to move (see [0009], “movement of the first manipulator assembly”) in response, at least in part, to the commanded movement (“movement”) of the second manipulator (“second manipulator assembly state signals being taken into consideration”). Before the invention was filed, it would have been obvious to a person of ordinary skill in the art to modify the three degrees of freedom of movement to the surgical instrument taught by the Moll et al. reference with the redundant degrees of freedom (RDOF) surgical robotic system taught by the Nowlin et al. reference. One of ordinary skill in the art would have been motivated to modify the three degrees of freedom of movement to the surgical instrument with the redundant degrees of freedom (RDOF) surgical robotic system so as to inhibit collisions between the manipulator assemblies. As per claim 2, the Moll et al. reference discloses the first manipulator (“master manipulator 404”) is a robotic arm assembly (see [0073], “one or more robotic arms”) having one or more joints (see [0078], “joints 222”) and one or more links (see [0078], “plurality of links 220”). As per claim 11, the Moll et al. reference discloses a method for controlling a device having a plurality of manipulators (see figure 11, “master manipulator 404, slave manipulator 416”), the method comprising: detecting, by one or more controllers (see figure 11, “master and slave joint controllers 560, 420”), movement of an input device (see figure 11, “master input controller 406, slave input/output module 414”); when movement of a first manipulator (“master manipulator 404”) is responsive to the movement (see [0070], “in response to movement”) of the input device (“master input controller 406”): determining, by the one or more controllers (“master and slave joint controllers 560, 420”), a commanded movement (see [0059], “movement”) for the first manipulator (“master manipulator 404”) from the detected movement of the input device (“master input controller 406”); and commanding, by the one or more controllers (“master and slave joint controllers 560, 420”), a second manipulator (“slave manipulator 416”) to move in response, at least in part, to the commanded movement (“movement”) of the first manipulator (“master manipulator 404”); and when movement of the second manipulator (“slave manipulator 416”) is responsive to the movement of the input device (slave input/output module 414”): determining, by the one or more controllers (“master and slave joint controllers 560, 420”), a commanded movement (“movement”) for the second manipulator (“slave manipulator 416”) from the detected movement of the input device (slave input/output module 414”); and commanding, by the one or more controllers (“master and slave joint controllers 560, 420”), the first manipulator (“master manipulator 404”) to move in response, at least in part, to the commanded movement (“movement”) of the second manipulator (“slave manipulator 416”). The Moll et al. reference does not expressly disclose the further limitations taught by the Nowlin et al. reference, namely: commanding, by the one or more controllers (see [0085], “master/slave controller 532”), a second manipulator to move in response, at least in part, to the commanded movement of the first manipulator (see [0005], “joints optionally being driven in response to movements of other joints”) and commanding, by the one or more controllers (“master/slave controller 532”), the first manipulator to move (see [0009], “movement of the first manipulator assembly”) in response, at least in part, to the commanded movement of the second manipulator (“second manipulator assembly state signals being taken into consideration”). Before the invention was filed, it would have been obvious to a person of ordinary skill in the art to modify the three degrees of freedom of movement to the surgical instrument taught by the Moll et al. reference with the redundant degrees of freedom (RDOF) surgical robotic system taught by the Nowlin et al. reference. One of ordinary skill in the art would have been motivated to modify the three degrees of freedom of movement to the surgical instrument with the redundant degrees of freedom (RDOF) surgical robotic system so as to inhibit collisions between the manipulator assemblies. As per claim 12, the Moll et al. reference discloses the first manipulator (“master manipulator 404”) is a robotic arm assembly (see [0073], “one or more robotic arms”) having one or more joints (see [0078], “joints 222”) and one or more links (see [0078], “plurality of links 220”). Claims 3 and 13 are rejected under pre-AIA 35 U.S.C. 103(a) as being unpatentable over US Pub. No. 2003/0013949 A1 (USPN 6,659,939 B2) to Moll et al. in view of US Pub. No. 2007/0013336 A1 (USPN 8,004,229 B2) to Nowlin et al., as applied to claims 1, 2, 11, 12 above, and further in view of US Pub. No. 2009/0036902 A (USPN 8,398,541 B2) to DiMaio et al. As per claims 3 and 13, the Moll et al. reference discloses the one or more controllers (“master and slave joint controllers 560, 420”) comprise a first controller (“master and slave joint controllers 560, 420”) and a second controller (“master and slave joint controllers 560, 420”); and the first controller (“master and slave joint controllers 560, 420”) is coupled to the second controller (“master and slave joint controllers 560, 420”) via a coupling block. Neither the Moll et al. nor Nowlin et al. reference expressly discloses the further limitations taught by the DiMaio et al. reference, namely: the first controller (see [0121], “master device”) is coupled to the second controller (“slave device”) via a coupling block (“collaborative control block 1508”). Before the invention was filed, it would have been obvious to a person of ordinary skill in the art to further modify the redundant degrees of freedom (RDOF) surgical robotic system taught by both the Moll et al. and Nowlin et al. references with the collaborative control block taught by the DiMaio et al. reference. One of ordinary skill in the art would have been motivated to further modify the redundant degrees of freedom (RDOF) surgical robotic system with the collaborative control block to provides a means to coordinate multiple manipulators. Allowable Subject Matter Claims 4-10 and 14-20 are objected to as being dependent upon a rejected base claim, but would be allowable if rewritten in independent form including all of the limitations of the base claim and any intervening claims. Conclusion The prior art made of record and not relied upon is considered pertinent to applicant's disclosure. The following references are cited to further show the state of the art with respect to robotic surgical system with multiple control modes: US 11337765 B2 to Mintz et al. US 10532467 B2 to Diolaiti et al. US 10405934 B2 to Prisco et al. US 10258416 B2 to Mintz et al. US 9566124 B2 to Prisco et al. US 9402689 B2 to Prisco et al. US 9241767 B2 to Prisco et al. US 9198730 B2 to Prisco et al. US 8914150 B2 to Moll et al. US 8666544 B2 to Moll et al. US 2009/0048611 A1 to Funda et al. JP 2004129782 A to FUJIO et al. JP 2641757 B2 to FURANKO CA 2289778 C to NISHIZAWA et al. Any inquiry concerning this communication or earlier communications from the examiner should be directed to Crystal J Barnes-Bullock whose telephone number is (571)272-3679. The examiner can normally be reached Monday - Friday 8 am - 5 pm. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Robert Fennema can be reached at 571-272-2748. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /CRYSTAL J BARNES-BULLOCK/Primary Examiner, Art Unit 2117 22 October 2026
Read full office action

Prosecution Timeline

Aug 21, 2024
Application Filed
Oct 26, 2026
Non-Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12800173
BUILDING SYSTEM WITH MULTI-TIERED MODEL BASED OPTIMIZATION FOR VENTILATION AND SETPOINT CONTROL
3y 5m to grant Granted Nov 17, 2026
Patent 12774825
Building as an Instrumentation for Data-Driven Building Operation
3y 4m to grant Granted Oct 27, 2026
Patent 12766995
INFORMATION PROCESSING METHOD
2y 10m to grant Granted Oct 20, 2026
Patent 12765475
HAND-HELD VAPOR PRESSURE DEFICIT MEASURING AND CONTROLLING DEVICE AND METHOD
2y 6m to grant Granted Oct 20, 2026
Patent 12756225
ELECTRIC POWER MANAGEMENT SYSTEM
2y 3m to grant Granted Oct 06, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
86%
Grant Probability
73%
With Interview (-13.1%)
2y 9m (~6m remaining)
Median Time to Grant
Low
PTA Risk
Based on 686 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month