Application No. 18/846,438

PROBE, SYSTEM, AND METHOD FOR FORMING A LESION IN A TARGET TISSUE

Final Rejection §102§103
Filed
Sep 12, 2024
Priority
Mar 15, 2022 — provisional 63/319,894 +1 more
Examiner
SHOULDERS, ANNIE LEE
Art Unit
3794
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Baylis Medical Technologies Inc.
OA Round
2 (Final)
75%
Grant Probability
Favorable
3-4
OA Rounds
1y 4m
Est. Remaining
93%
With Interview

Examiner Intelligence

Grants 75% — above average
75%
Career Allowance Rate
163 granted / 218 resolved
+4.8% vs TC avg
Strong +18% interview lift
Without
With
+18.2%
Interview Lift
resolved cases with interview
Typical timeline
3y 6m
Avg Prosecution
38 currently pending
Career history
263
Total Applications
across all art units

Statute-Specific Performance

§101
0.4%
-39.6% vs TC avg
§103
58.1%
+18.1% vs TC avg
§102
18.9%
-21.1% vs TC avg
§112
15.8%
-24.2% vs TC avg
Black line = Tech Center average estimate • Based on career data from 218 resolved cases

Office Action

§102 §103
DETAILED ACTION Notice of Pre-AIA or AIA Status 1. The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . 2. In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. Response to Arguments 3. Applicant's arguments filed 8/18/2026 have been fully considered but they are not persuasive. 4. Regarding Claims 1, 22, and 23, the applicant argues that Cosman U.S. xx fails to teach the “first temperature sensor is positioned proximally of the distal end and is spaced from the cooled section”. They cite Figure 2 embodiment that discloses a temperature sensor found distal of the distal end of the active electrode tip. However, the examiner disagrees with these arguments. 5. In the most recent office action (filed 5/19/2025), the examiner does not rely upon the Figure 2 embodiment to teach the limitations recited in Claims 1, 22, and 23. The applicant also points to the specification of Cosman which states that the “cooled RF electrode temperature sensor [may be] on outer surface proximal to the active tip” (see para 0139 of Cosman OR pg. 3 of NFOA). This proves there is a structural description that satisfies the present claim language. It is also found that the arrangement/rearrangement of parts involves only routine skin in the art (In re Japikse, 86 USPQ 70). Therefore, Cosman reads on the present claim language, and the current rejection stands. 6. The applicant also argues that arranging the probe of Cosman to have the temperature sensor be proximal to the distal end would render the device inoperable. However, since Cosman does contemplate that the temperature sensor may be arranged in such a way, this indicates that the intended use of the device is still operational, rendering the argument moot. 7. The applicant also argues that the structural arrangement of the temperature sensor in regards to thermal/insulative barriers renders the device ineffective. However, there is no claim language present that shows the structural relationship between the temperature sensor and the insulation section. Although the claims are interpreted in light of the specification, limitations from the specification are not read into the claims. See In re Van Geuns, 988 F.2d 1181, 26 USPQ2d 1057 (Fed. Cir. 1993). 8. Regarding Claims 5 and 6, the applicant relies on arguments that have been addressed above. The applicant also states that the combination of references fails to teach a temperature sensor secured directly to the active metal in a non-cooled portion of the active electrode. However, there is no language present in the claims that reflects this feature. Therefore, the argument is moot and the rejection stands. 9. Regarding Claim 12, the applicant relies on arguments that have been addressed above. Therefore, the rejection stands. 10. Regarding Claim 15, the examiner finds the arguments persuasive, therefore, they have been withdrawn. Claim Rejections - 35 USC § 102 11. The text of those sections of Title 35, U.S. Code not included in this action can be found in a prior Office action. 12. Claims 1, 2, 8, 19, 14, 18, 22, 23, 26, and 27 are rejected under 35 U.S.C. 102(a)(1) as being anticipated by Cosman U.S. 2020/0330153 (herein referred to as “Cosman”). 13. Regarding Claim 1, Cosman teaches a probe for forming a lesion in a target tissue (Fig. 1A, para 0086, “an apparatus for HF ablation of tissue within a patient”), the probe comprising: a. an elongate member extending longitudinally between a proximal end and a distal end (Fig. 1A, ref num 150), wherein the elongate member has an active electrode proximate the distal end for delivering ablative energy to the target tissue (Fig. 1A, ref num 151; para 0093, “electrode active tip”), and an electrically insulated section proximal of the active electrode (Fig. 1A, ref num 152 is proximal of ref num 151; para 0100, “an insulated portion 152”), and wherein the active electrode has a cooled section that is coolable by receipt of a cooling fluid delivered through the elongate member (para 0105, “one example of a coolant supply system 130 to cool the active tip portion 151… Tubing 155 carries the coolant through a peristaltic pump head 131 that pumps the coolant through the electrode 150E, and thus the ablation probe assembly 150. The electrode 150E has an internal channel through which coolant an flow to cool the probe”); and b. at least a first temperature sensor (para 0128, “a temperature sensor configured to monitor tissue temperature distal to the active tip 161 of the electrode 160”) positioned external of the elongate member to measure a temperature in a heat affected zone of the target tissue (para 0139, “cooled RF electrode temperature sensory on outer surface proximal to the active tip”), wherein the first temperature sensor is positioned proximally of the distal end and is spaced from the cooled section (para 0139, “temperature sensor on outer surface proximal to the active tip”). 14. Regarding Claim 2, Cosman teaches the elongate member comprises at least a first fluid delivery lumen for delivering the cooling fluid through the elongate member to the cooled section (para 0105, “Tubing 155 carries the coolant through a peristaltic pump head 131 that pumps the coolant through the electrode 150E, and thus the ablation probe assembly 150. The electrode 150E has an internal channel through which coolant can flow to cool the probe active tip 151”). 15. Regarding Claim 8, Cosman teaches the first temperature sensor is positioned proximally of the active electrode (para 0139, “cooled RF electrode temperature sensory on outer surface proximal to the active tip”). 16. Regarding Claim 10, Cosman teaches the first temperature sensor is positioned to measure the temperature in a proximal projection of a thermal ablation zone (Fig. 1B, ref num 167 is proximal of ref num 193, the thermal ablation zone). 17. Regarding Claim 14, Cosman teaches the elongate member comprises a metallic hypotube (para 0101, “The thickness and material of the internally-cooled electrode shaft 152B and blunt distal end 151B (eg thin-wall stainless steel hypotube with a thin-wall closed distal end), the thickness and material of the cannula shaft 152 and active tip 151 (eg thin-wall stainless steel hypotube covered by a thin layer of electrical insulation in shaft portion 152)… the electrode shaft 152B can include a metallic outer surface”), wherein the metallic hypotube comprises a first section that is electrically exposed to form the active electrode (see Fig. 1A, ref num 151 is exposed to form the active electrode), and a second section on which an electrically insulative material is received to from the electrically insulative section (para 0101, “thin-wall stainless steel hypotube covered by a thin layer of electrical insulation in shaft portion 152”). 18. Regarding Claim 18, Cosman teaches at least one electrical conductor for electrically connecting the first temperature sensor to a temperature control system (para 0129, “the distal extension tip 167 can comprise a stainless steel tube, a temperature sensor at the distal point of the tube (for example, formed by welding a constantan wire within the stainless steel tube to the distal end of the stainless steel tube)” it is understood that the sensor would be connected to a control system, i.e., Fig. 1B, ref num 100), wherein the electrical conductor extends through a lumen of the elongate member (the distal extension tip 167 can comprise a stainless steel tube, a temperature sensor at the distal point of the tube (for example, formed by welding a constantan wire within the stainless steel tube to the distal end of the stainless steel tube), electrical insulation (which can comprise a plastic coating or sheath along the tube, and glue covering wire connections at the tube proximal end) covering all but the distal point of the tube). 19. Regarding Claim 22, Cosman teaches a system for forming a lesion in a target tissue (Fig. 1A, para 0086, “an apparatus for HF ablation of tissue within a patient”), comprising: a. a probe (Fig. 1A, para 0086, “an apparatus for HF ablation of tissue within a patient”) comprising an elongate member extending longitudinally between a proximal end and a distal end (Fig. 1A, ref num 150), wherein the elongate member has an active electrode proximate the distal end for delivering ablative energy to the target tissue (Fig. 1A, ref num 151; para 0093, “electrode active tip”), and an electrically insulated section proximal of the active electrode (Fig. 1A, ref num 152 is proximal of ref num 151; para 0100, “an insulated portion 152”), and wherein the active electrode has a cooled section that is coolable by receipt of a cooling fluid delivered through the elongate member (para 0105, “one example of a coolant supply system 130 to cool the active tip portion 151… Tubing 155 carries the coolant through a peristaltic pump head 131 that pumps the coolant through the electrode 150E, and thus the ablation probe assembly 150. The electrode 150E has an internal channel through which coolant an flow to cool the probe”); and at least a first temperature sensor (para 0128, “a temperature sensor configured to monitor tissue temperature distal to the active tip 161 of the electrode 160”) positioned external of the elongate member to measure a temperature in a heat affected zone of the target tissue (para 0139, “cooled RF electrode temperature sensory on outer surface proximal to the active tip”), wherein the first temperature sensor is positioned proximally of the distal end and is spaced from the cooled section (para 0139, “temperature sensor on outer surface proximal to the active tip”). b. a return electrode spaced from the active electrode (Fig. 1A, ref nums 121-124; para 0086, “the ground pads 121, 122, 123, and 124 can be connected to a reference potential generated by the HF generator 100 to carry return currents from the ablation probe”) c. a radiofrequency generator (Fig. 1A, ref num 100) electrically connected to the active electrode for delivering the ablative energy to the active electrode (Fig. 1A, ref num 100 is connected to electrode; para 0086) and electrically connected to the return electrode for returning a return current to the radiofrequency generator (para 0086); and d. a cooling fluid circulation system for delivering the cooling fluid to the probe (Fig. 1A, ref num 130; para 0086, “a coolant pump 130 that is configured to cool one or more of the ablation probes”). 20. Regarding Claim 23, Cosman teaches a method for forming a lesion in a target tissue (Fig. 1A, para 0086, “an apparatus for HF ablation of tissue within a patient”), comprising: positioning an active electrode of a probe at the target tissue (Fig. 1A, ref num 151 in tissue 190); delivering ablative energy from the active electrode to form the lesion in the target tissue (para 0093, “The upward spikes in impedance, such as spike 118, represent the occurrence of boiling and bubble formation in the tissue around the active or exposed tip of the ablation electrode 150. The bubble zone is the hottest region around the electrode active tip 151 and is located at a distance from the electrode tip 151”), while delivering a cooling fluid to a cooled section of the active electrode (Fig. 1A, ref num 130; para 0105); and using a first temperature sensor of the probe to monitor a temperature in a heat affected zone of the target tissue at a position proximal of a distal end of the probe and spaced from the cooled section (para 0128, “a temperature sensor configured to monitor tissue temperature distal to the active tip 161 of the electrode 160”; para 0139, “cooled RF electrode temperature sensory on outer surface proximal to the active tip”). 21. Regarding Claim 26, Cosman teaches the first temperature sensor comprises monitoring the temperature proximally of the active electrode (para 0139, “cooled RF electrode temperature sensory on outer surface proximal to the active tip”). 22. Regarding Claim 27, Cosman teaches wherein the lesion has a proximal projection, and the first temperature sensor measures the temperature in the proximal projection (Fig. 1B, ref num 167 is proximal of ref num 193, the thermal ablation zone). Claim Rejections - 35 USC § 103 23. The text of those sections of Title 35, U.S. Code not included in this action can be found in a prior Office action. 24. Claims 4-6, 25, and 28 are rejected under 35 U.S.C. 103 as being unpatentable over Cosman and in view of Koblish U.S. 9,023,030 (herein referred to as “Koblish”). 25. Regarding Claim 4, Cosman fails to teach the elongate member is configured to restrict the cooling fluid to the cooled section on delivery of the cooling fluid. Koblish teaches a probe of analogous art (Fig. 1), wherein the probe comprises an elongate member (Fig. 1, ref num 12) that is configured to restrict a cooling fluid to a cooled section on delivery of the cooling fluid (Col. 5, lines 53-55, “The cooling chamber can receive a flow of fluid to draw heat away [from] the proximal portion of the electrode”; Col. 4, lines 19-21, “the electrode tip can comprise a proximal cooling chamber through which cooling fluid circulates”). This reduces hotspots within the tip of the probe (abstract, Col. 4, lines 22-23). Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Cosman to restrict the cooling fluid to the cooled section in order to reduce the hotspots in the tip of the probe. 26. Regarding Claim 5, Cosman fails to teach a barrier within the elongate member for restricting the cooling fluid to the cooled section on delivery of the cooling fluid, wherein the barrier is positioned distally of a proximal boundary of the active electrode, to further provide the active electrode with a non-cooled section. Koblish teaches a barrier within the elongate member for restricting the cooling fluid to the cooled section on delivery of the cooling fluid (Fig. 2A, ref num 60; Col. 5, lines 53-55, “the cooling chamber can receive a flow of fluid to draw heat away [from] the proximal portion of the electrode”), wherein the barrier is positioned distally of a proximal boundary of the active electrode (see Fig. 2A, ref num 60 is distal to ref num 48), to further provide the active electrode with a non-cooled section (Fig. 2A, the non-cooled section is proximal to ref num 62; i.e., the cooled chamber). This controls the temperature of the tip of the electrode to reduce hotspots (Col. 5, lines 25-28). Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Cosman to restrict the cooling fluid to the cooled section in order to reduce the hotspots in the tip of the probe. 27. Regarding Claim 6, Cosman teaches the first temperature sensor is secured to the active electrode in the non-cooled section (para 0016, “temperature can be measured almost directly by means of the non-cooled-electrode's temperature sensor”). 28. Claim 7 is rejected under 35 U.S.C. 103 as being unpatentable over Cosman and in view of Leung U.S. 10,610,297 (herein referred to as “Leung”). 29. Regarding Claim 7, Cosman fails to teach a barrier within the elongate member for restricting the cooling fluid to the cooled section on delivery of the cooling fluid, wherein the barrier is positioned at a proximal boundary of the active electrode so that the cooled section makes up an entirety of the active electrode. Leung teaches a system of analogous art (Fig. 1), wherein the system comprises a barrier within an elongate member (Fig. 1, ref num 190 has a barrier, also see Fig. 4) for restricting cooling fluid to a cooled section on delivery of the cooling fluid (Fig. 4, ref num 450, 408; Col. 13, lines 28-30, “wherein arrow 408 indicates the direction of cooling fluid flow within a lumen 450 defined by the one or more energy delivery devices 192”), wherein the barrier is positioned at a proximal boundary of the active electrode so that the cooled section makes up an entirety of the active electrode (Fig. 4, ref num 408 shows the flow of the cooling fluid that makes up the active electrode, i.e., ref num 192). This provides cooling to the electrode (Col. 16, lines 55-67 – Col. 17, line 1, “The silver solder fills the lumen such that any cooling fluid supplied to probe assembly 106, that is not located within one of the cooling tubes described earlier, is confined to the distal tip region 190 of probe assembly 106. Thus, in this embodiment, the silver solder may be referred to as a flow impeding structure since it functions to restrict the circulation of fluid to a specific portion (in this case, at least a portion of distal region 190) of probe assembly 106. In other words, cooling fluid may flow from the one or more cooling devices 108, through the cooling supply tubes described earlier, to distal tip region 190 of probe assembly 106. The cooling fluid may then circulate within lumen 450 defined by electrode 192 in order to provide cooling to the electrode”). Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Cosman to have a barrier positioned such that the cooled section makes up an entirety of the active electrode in order to cool the electrode. 30. Claim 12 is rejected under 35 U.S.C. 103 as being unpatentable over Cosman and in view of Curley U.S. 2020/0138502 (herein referred to as “Curley”). 31. Regarding Claim 12, Cosman fails to teach the first temperature sensor is spaced at least proximally from the cooled section. Curley teaches a system of analogous art (Fig. 1), wherein a temperature sensor is spaced at least proximally from the cooled section (Fig. 6, ref num 614 is a temperature sensor that is proximal to the distal end where the cooling fluid is circulated; para 0069-0070). By placing the temperature sensor proximally to the cooled section, the completion of the therapy is indicated by the sensor (para 0072). Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Cosman to have the temperature sensor placed proximal to the cooled section in order to track the completion of the therapy to the target site. 32. Claims 20 and 32 are rejected under 35 U.S.C. 103 as being unpatentable over Cosman and in view of Engelman U.S. 2014/0018788 (herein referred to as “Engelman”). 33. Regarding Claim 20, Cosman fails to teach the first temperature sensor is further configured to deliver ablative energy to the target tissue. Engelman teaches a system of analogous art wherein a temperature sensor is further configured to deliver ablative energy to the target tissue (para 0144, “additional sensors 364 (e.g., temperature sensors such as a thermocouple or thermistor) may be mounted in the flex circuit proximate to the electrodes and may be used to monitor or control delivery of ablation energy”). This produces the same expected result of delivery ablative energy to the target tissue (para 0144). Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Cosman to have the temperature sensor deliver ablative energy to the target tissue as this produces the same expected result of ablating the target tissue. 34. Regarding Claim 32, Cosman fails to teach the first temperature sensor is further configured to deliver ablative energy to the target tissue. Engelman teaches a system of analogous art wherein a temperature sensor is further configured to deliver ablative energy to the target tissue (para 0144, “additional sensors 364 (e.g., temperature sensors such as a thermocouple or thermistor) may be mounted in the flex circuit proximate to the electrodes and may be used to monitor or control delivery of ablation energy”). This produces the same expected result of delivery ablative energy to the target tissue (para 0144). Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Cosman to have the temperature sensor deliver ablative energy to the target tissue as this produces the same expected result of ablating the target tissue. Allowable Subject Matter 35. Claim 15 contains allowable subject matter. 36. The following is a statement of reasons for the indication of allowable subject matter: after considering the remarks of the applicant (filed 8/18/2026), the examiner agrees that the prior art fails to teaches at least one electrical conductor for electrically connecting the first temperature sensor to a temperature control system, wherein the electrical conductor is positioned between the second section of the metallic hypotube and the electrically insulative material. 37. However, Claim 15 is objected to as being dependent upon a rejected base claim, but would be allowable if rewritten in independent form including all of the limitations of the base claim and any intervening claims. Conclusion 38. THIS ACTION IS MADE FINAL. Applicant is reminded of the extension of time policy as set forth in 37 CFR 1.136(a). A shortened statutory period for reply to this final action is set to expire THREE MONTHS from the mailing date of this action. In the event a first reply is filed within TWO MONTHS of the mailing date of this final action and the advisory action is not mailed until after the end of the THREE-MONTH shortened statutory period, then the shortened statutory period will expire on the date the advisory action is mailed, and any nonprovisional extension fee (37 CFR 1.17(a)) pursuant to 37 CFR 1.136(a) will be calculated from the mailing date of the advisory action. In no event, however, will the statutory period for reply expire later than SIX MONTHS from the mailing date of this final action. 39. Any inquiry concerning this communication or earlier communications from the examiner should be directed to ANNIE L SHOULDERS whose telephone number is (571)272-3846. The examiner can normally be reached Monday-Friday (alternate Fridays) 8AM-5PM EST. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Joseph Stoklosa can be reached at 571-272-1213. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /ANNIE L SHOULDERS/Primary Examiner, Art Unit 3794
Read full office action

Prosecution Timeline

Sep 12, 2024
Application Filed
Oct 11, 2025
Response after Non-Final Action
May 19, 2026
Non-Final Rejection mailed — §102, §103
Aug 18, 2026
Response Filed
Oct 23, 2026
Final Rejection mailed — §102, §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12702473
SYSTEMS FOR IMPROVING THE APPEARANCE OF TISSUE
4y 0m to grant Granted Aug 11, 2026
Patent 12702476
FORCE SENSING CATHETER INCLUDING SEALED ELECTRODE TIP ASSEMBLY AND METHODS OF ASSEMBLING SAME
2y 2m to grant Granted Aug 11, 2026
Patent 12678223
SYSTEMS AND METHODS FOR CYLINDRICAL CAGE MAPPING AND ABLATION CATHETERS HAVING FLEXIBLE CIRCUITS
2y 8m to grant Granted Jul 14, 2026
Patent 12678327
CAPSULOTOMY DEVICE
2y 7m to grant Granted Jul 14, 2026
Patent 12643111
NANO SURFACES ON SMOKE PARTICLE ELECTRODES
3y 7m to grant Granted Jun 02, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
75%
Grant Probability
93%
With Interview (+18.2%)
3y 6m (~1y 4m remaining)
Median Time to Grant
Moderate
PTA Risk
Based on 218 resolved cases by this examiner. Grant probability derived from career allowance rate.