Prosecution Insights
Last updated: November 04, 2026
Application No. 18/897,818

INTRAOCULAR PRESSURE MEASUREMENT SYSTEM AND METHOD

Non-Final OA §103
Filed
Sep 26, 2024
Priority
Sep 26, 2023 — provisional 63/540,521
Examiner
JANG, ELINA SOHYUN
Art Unit
3791
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Nogalmedicine GmbH
OA Round
1 (Non-Final)
68%
Grant Probability
Favorable
1-2
OA Rounds
1y 2m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 68% — above average
68%
Career Allowance Rate
69 granted / 102 resolved
-2.4% vs TC avg
Strong +38% interview lift
Without
With
+38.0%
Interview Lift
resolved cases with interview
Typical timeline
3y 4m
Avg Prosecution
17 currently pending
Career history
124
Total Applications
across all art units

Statute-Specific Performance

§101
12.7%
-27.3% vs TC avg
§103
36.5%
-3.5% vs TC avg
§102
17.8%
-22.2% vs TC avg
§112
29.5%
-10.5% vs TC avg
Black line = Tech Center average estimate • Based on career data from 102 resolved cases

Office Action

§103
Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Election/Restrictions Claims 3 and 8-20 are withdrawn from further consideration pursuant to 37 CFR 1.142(b) as being drawn to a nonelected group, there being no allowable generic or linking claim. Election was made without traverse in the reply filed on 9/23/2026. Drawings Figure 5 should be designated by a legend such as --Prior Art-- because only that which is old is illustrated. See MPEP § 608.02(g). Corrected drawings in compliance with 37 CFR 1.121(d) are required in reply to the Office action to avoid abandonment of the application. The replacement sheet(s) should be labeled “Replacement Sheet” in the page header (as per 37 CFR 1.84(c)) so as not to obstruct any portion of the drawing figures. If the changes are not accepted by the examiner, the applicant will be notified and informed of any required corrective action in the next Office action. The objection to the drawings will not be held in abeyance. Claim Rejections - 35 USC § 103 In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. The factual inquiries for establishing a background for determining obviousness under 35 U.S.C. 103 are summarized as follows: 1. Determining the scope and contents of the prior art. 2. Ascertaining the differences between the prior art and the claims at issue. 3. Resolving the level of ordinary skill in the pertinent art. 4. Considering objective evidence present in the application indicating obviousness or nonobviousness. Claims 1-2 and 4-6 are rejected under 35 U.S.C. 103 as being unpatentable over WO2015114446A1 (Nogal, Piotr), hereto referred as Nogal, and in view of US20110292336A1 (Deacon et. al), hereto referred as Deacon. As to claim 1, Nogal teaches a system for measuring intraocular pressure (IOP), comprising: a tonometer head configured to measure IOP in a posterior chamber and a vitreous cavity of an eye (Nogal, pg. 5, "The invention is a non-invasive contact compression and refraction tonometer to measure the intraocular pressure of the posterior chamber of the eye and the vitreous chamber, characterized by a head"); an optical gauge configured to measure corneal data of the eye (Nogal, pg. 5, "the optic meter measuring corneal astigmatism is a keratometer"); a processor configured to determine geometric parameters of the eye based on the measured corneal data, calculate physical parameters of a sclera of the eye based on the determined geometric parameters (Nogal, pg. 7, "calculating the corneal stiffness coefficient, conditioned by its thickness and the pressure in the anterior chamber of the eye"), and adjust the measured IOP based on the calculated physical parameters of the sclera (Nogal, pg. 12, "which allows to increase the measurement precision by recalculating the stiffness coefficient of the walls of the eyeball through referring the result to the table developed on the basis of measurements conducted in control groups"). Nogal teaches compression arms (Nogal, pg. 11, "setting the open compression arms (11) at such a distance and under such an angle in relation to the eyeball"), but does not teach a compression arm-spread angle gauge configured to measure a dilation angle of compression arms. Deacon teaches a similar art of analyzing the eye (Deacon, abstract). Deacon teaches compression arm-spread angle gauge configured to measure a dilation angle of compression arms (Deacon, [0091], " In certain embodiments, an electronic or digital image of the angle indicator 30 in the eye and/or the protractor 70 is produced. The digital image may be captured and processed using a computer or other electronic system in order to determine the angle between the two straight sections 32 and 33.") It would have been prima facie obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Nogal in view of Deacon to include compression arm-spread angle gauge configured to measure a dilation angle of compression arms because Nogal already places compression arms at an angle to the eyeball, and Deacon teaches a method of angle measurement, which increases the accuracy of the measurement and provides dimensional information about the eye. Nogal does not expressly teach determining geometric parameters of the eye based on both the measured corneal data and dilation angle. Deacon teaches an ocular geometric parameter, including diameter from a measured angle associated with two connected members of an ocular measuring (Deacon, [0031], “the read angle is converted to a capsular bag size”), and also teaches converting an angular measurement into a corresponding ocular diameter (Deacon, [0101], “the resulting size difference may be measured and used to calculate a resiliency of the capsular bag and/or estimate the amount of accommodative force available for accommodation”). It would have been prima facie obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have further modified Nogal in view of Deacon to include determining geometric parameters of the eye based on both the measured corneal data and dilation angle and adjust the measured IOP because doing so would improve the accuracy of IOP from accounting for various dimensions and characteristics of the eye. As to claim 2, Nogal-Deacon teaches the optical gauge comprises a keratometer configured to measure corneal curvature (Nogal, pg. 12, "which allows to increase the measurement precision by recalculating the stiffness coefficient of the walls of the eyeball through referring the result to the table developed on the basis of measurements conducted in control groups"). As to claim 4, Nogal-Deacon teaches the compression arm-spread angle gauge is configured to measure the dilation angle when compression feet of the compression arms contact the eye at a predetermined distance from a corneal limbus (Deacon, [0073], "one angle measurement embodiment is a protractor that may be removably placed on the cornea"; Nogal, pg. 5, "beneficially 3-5 mm toward the back from the corneal limbus"). It would have been prima facie obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have further modified Nogal in view of Deacon to include measuring the dilation angle when compression feet of the compression arms contact the eye because Nogal already places compression arms at an angle to the eyeball, and measuring when the arms contact the eye gives accurate dimensional information about the eye. As to claim 5, Nogal-Deacon teaches the predetermined distance is between 3-5 mm posterior to the corneal limbus (Nogal, pg. 5, "beneficially 3-5 mm toward the back from the corneal limbus"). As to claim 6, Nogal-Deacon teaches further comprising an axial drive configured to maintain the optical gauge at a constant distance from a cornea of the eye during measurement (Nogal, pg. 5, "the head (1) is set relative to the eye using distance actuators (17) controlled by a computer (15)."). Claim 7 is rejected under 35 U.S.C. 103 as being unpatentable over Nogal and Deacon as applied to claim 1 above, and further in view of US20140268042A1 (Bor et. al), hereto referred as Bor, and in view of US20190105200A1 (Hipsley, Annmaire), hereto referred as Hipsley. Claim 1 is taught as above. As to claim 7, Nogal-Deacon teaches further comprising a camera (Nogal, pg. 5, "optic meter"); however, Nogal does not teach a camera configured to capture an image of an anterior surface of a lens of the eye to determine a degree of porosity of an anterior lens capsule. Bor teaches a camera configured to capture an image of an anterior surface of a lens of the eye (Bor, [0022], "The detector can comprise a digital imaging device such as a charge coupled detector (CCD), CMOS Sensor or a photodiode.”; [0021], "measuring the resulting first image of the light sources reflected from an anterior surface of the lens"). It would have been prima facie obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Nogal-Deacon in view of Bor to include a camera configured to capture an image of an anterior surface of a lens of the eye because Nogal-Deacon already teaches an optical measurement system, and Bor supplies imaging that further teaches imaging anterior surface of a lens which enables non-invasively obtaining additional data about the eye. Hipsley teaches a camera (Hipsley, Fig. 3A, camera 308 ) and determining a degree of porosity of an anterior lens capsule (Hipsley, [0310], "Broadly put, the diagram represents the use of a camera, for example, a CCD or CMOS camera to capture an image of eye"; [0317], "microporation/nanoporation may be used to remove surface, subsurface and interstitial tissue and affect the surface, interstitial, biomechanical characteristics (e.g., planarity, surface porosity"). It would have been prima facie obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified Norgal-Deacon-Bor in view of Hipsley to include a camera configured to capture an image of an anterior surface of a lens of the eye to determine a degree of porosity of an anterior lens capsule because Norgal-Deacon-Bor already teaches tissue image analysis of the anterior surface of a lens, and Hipsley teaches further quantitative analysis of the anterior surface of a lens using the camera. Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to ELINA S JANG whose telephone number is (571)272-7019. The examiner can normally be reached M-F 9:00 am - 6:00 pm. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Jennifer Robertson can be reached at (571) 272-5001. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /ELINA SOHYUN JANG/Examiner, Art Unit 3791 /JENNIFER ROBERTSON/Supervisory Patent Examiner, Art Unit 3791
Read full office action

Prosecution Timeline

Sep 26, 2024
Application Filed
Oct 23, 2026
Non-Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12765833
METHOD AND APPARATUS FOR ANALYZING SPECTRUM OF AUDITORY THERAPY FREQUENCIES
4y 7m to grant Granted Oct 20, 2026
Patent 12765820
OCULAR SYSTEM FOR DIAGNOSING AND MONITORING MENTAL HEALTH
4y 7m to grant Granted Oct 20, 2026
Patent 12758100
WEARABLE DEVICE AND METHOD FOR PERFORMING REGISTRATION PROCESS IN THE WEARABLE DEVICE
2y 10m to grant Granted Oct 13, 2026
Patent 12752029
TECHNIQUES FOR OLFACTORY TRAINING USING SCENT DISPENSING DEVICES
1y 11m to grant Granted Oct 06, 2026
Patent 12733821
IMPLANTABLE CEREBRAL SENSING DEVICES AND SYSTEMS AND METHODS RELATED THERETO
4y 11m to grant Granted Sep 15, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
68%
Grant Probability
99%
With Interview (+38.0%)
3y 4m (~1y 2m remaining)
Median Time to Grant
Low
PTA Risk
Based on 102 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month