Prosecution Insights
Last updated: November 04, 2026
Application No. 18/912,613

AIR FLOW-BASED COOLING DEVICE

Non-Final OA §102
Filed
Oct 11, 2024
Priority
Oct 13, 2023 — RE 10-2023-0136992
Examiner
TIGHE, DANA K
Art Unit
3762
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Alls-Well Co. Ltd.
OA Round
1 (Non-Final)
76%
Grant Probability
Favorable
1-2
OA Rounds
1y 2m
Est. Remaining
93%
With Interview

Examiner Intelligence

Grants 76% — above average
76%
Career Allowance Rate
509 granted / 672 resolved
+5.7% vs TC avg
Strong +17% interview lift
Without
With
+16.9%
Interview Lift
resolved cases with interview
Typical timeline
3y 3m
Avg Prosecution
23 currently pending
Career history
705
Total Applications
across all art units

Statute-Specific Performance

§101
0.5%
-39.5% vs TC avg
§103
51.5%
+11.5% vs TC avg
§102
17.5%
-22.5% vs TC avg
§112
28.1%
-11.9% vs TC avg
Black line = Tech Center average estimate • Based on career data from 672 resolved cases

Office Action

§102
DETAILED ACTION The present office action is in response to claims filed on 10/11/2024. Claims 1 – 8 are pending in the application. The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. Claim Objections Claim 1, 2, and 8 are objected to because of the following informalities: Claim 1 recites “a horizontal air flow” in line 7, which should recite “the horizontal air flow” for proper antecedent basis. Claim 1 recites “the first vertical air” in lines 6 and 12-13, which should recite “the first vertical air flow” for proper antecedent basis. Claim 1 recites “the second vertical air” in lines 14-15, which should recite “the second vertical air flow” for proper antecedent basis. Claim 2 recites “the first and second vertical airs” in line 2, which should recite “the first and second vertical air flows” for proper antecedent basis. Claim 8 recites “the first and second vertical airs” in line 4, which should recite “the first and second vertical air flows” for proper antecedent basis. Claim 8 recites “the first vertical air” in line 3, which should recite “the first vertical air flow” for proper antecedent basis. Claim 8 recites “the second vertical air” in line 3, which should recite “the second vertical air flow” for proper antecedent basis. Appropriate correction is required Claim 6 is objected to under 37 CFR 1.75 as being a substantial duplicate of claim 4. When two claims in an application are duplicates or else are so close in content that they both cover the same thing, despite a slight difference in wording, it is proper after allowing one claim to object to the other as being a substantial duplicate of the allowed claim. See MPEP § 608.01(m). Claim Rejections - 35 USC § 102 The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale or otherwise available to the public before the effective filing date of the claimed invention. (a)(2) the claimed invention was described in a patent issued under section 151, or in an application for patent published or deemed published under section 122(b), in which the patent or application, as the case may be, names another inventor and was effectively filed before the effective filing date of the claimed invention. Claims 1, 2, 3, and 8 are rejected under 35 U.S.C. 102(a)(1) as being anticipated by Roth (U.S. Patent No. 9,781,865). Regarding Claim 1, Roth shows (Figures 1 and 2): An air flow-based cooling device (100) comprising: a vertically stacked cell string (112) formed by vertically stacking (as illustrated in Figure 2) a plurality of cells (208), each (each individual 208) of the plurality of cells (208) having a heat-generating object (“computer equipment”, Col. 4, lines 54-55) installed therein; an air intake pipe (110) installed to vertically penetrate (as illustrated in Figure 1) one end (the bottom end) of the vertically stacked cell string (112) and generate a first vertical air flow (the flow of air through 112) through an intake splitter (adjustable nozzles of 206) at an air inlet (the left side of 212/214, as illustrated in Figure 2) and distribute the first vertical air flow (the flow of air through 112) as a horizontal air flow (the flow through the adjustable nozzles of 206 through 208) through an intake opening (the air inlet on the left side of each 208; “rack 208 of computer equipment will have its own internal fan unit helping to move air through rack 208”, Col. 4, lines 54-56) in each (each individual 208) of the plurality of cells (208), thereby generating the horizontal air flow (the flow through the adjustable nozzles of 206 through 208); an air discharge pipe (114) installed to discharge (as illustrated by the air flow arrows in Figure 2) the horizontal air flow (the flow through the adjustable nozzles of 206 through 208) through a discharge opening (the air outlet on the right side of each 208; “rack 208 of computer equipment will have its own internal fan unit helping to move air through rack 208”, Col. 4, lines 54-56) in each (each individual 208) of the plurality of cells (208) and vertically penetrate (as illustrated in Figure 2) the other end (the top end, as illustrated in Figure 2) of the vertically stacked cell string (112) to generate a second vertical air flow (the vertical air flow formed from the discharge of 208 through 114) using the horizontal air flow (the flow through the adjustable nozzles of 206 through 208) through a discharge splitter (the curved flow guide installed within 112 at the inlet of 114, as illustrated in Figure 2) installed in an air outlet (the right side of 210 and 213/215, as illustrated in Figure 2); an air intake duct (106) connected to one end (the bottom end of 110, as illustrated in Figure 2) of the air intake pipe (110) and providing (as illustrated by the air flow arrows in Figure 2) the first vertical air flow (the flow of air through 112) to the intake splitter (adjustable nozzles of 206); and an air discharge duct (116) connected to one end (the top end of 114, as illustrated in Figure 2) of the air discharge pipe (114) and receiving (as illustrated by the air flow arrows in Figure 2) the second vertical air flow (the vertical air flow formed from the discharge of 208 through 114) from the discharge splitter (the curved flow guide installed within 112 at the inlet of 114, as illustrated in Figure 2). Regarding Claim 2, Roth shows (Figures 1 and 2): By placing (as illustrated by the air flow arrows in Figure 2) the intake opening (the air inlet on the left side of each 208; “rack 208 of computer equipment will have its own internal fan unit helping to move air through rack 208”, Col. 4, lines 54-56) at a contact point (the left side of 210, 212/214 is a fluid contact point between 110 and the inlet of 208) of the air intake pipe (110) in each (each individual 208) of the plurality of cells (208) and the discharge opening (the air outlet on the right side of each 208; “rack 208 of computer equipment will have its own internal fan unit helping to move air through rack 208”, Col. 4, lines 54-56) at a contact point (the right side of 210, 213/215 is a fluid contact point between the outlet of 208 and 114) of the air discharge pipe (114), the vertically stacked cell string (112) is designed to generate (as illustrated by the air flow arrows in Figure 2) circulation of the first (the flow of air through 112) and second (the vertical air flow formed from the discharge of 208 through 114) air flows, with the intake opening (the air inlet on the left side of each 208; “rack 208 of computer equipment will have its own internal fan unit helping to move air through rack 208”, Col. 4, lines 54-56) and the discharge opening (the air outlet on the right side of each 208; “rack 208 of computer equipment will have its own internal fan unit helping to move air through rack 208”, Col. 4, lines 54-56) to face each other (as illustrated in Figure 2, the inlet and outlet are on opposite ends of 208 and therefore face each other). Regarding Claim 3, Roth shows (Figures 1 and 2): The vertically stacked cell string (112) has the air intake pipe (110) and the air discharge pipe (114) arranged at central opposing points (the bottom left side of 218 and the top right side of 220, as illustrated in Figure 2) of the plurality of cells (208) to allow the horizontal air flow (the flow through the adjustable nozzles of 206 through 208) to pass through (as illustrated by the air flow arrows in Figure 2; “rack 208 of computer equipment will have its own internal fan unit helping to move air through rack 208”, Col. 4, lines 54-56) the heat-generating object (“computer equipment”, Col. 4, lines 54-55). Regarding Claim 8, Roth shows (Figures 1 and 2): The air intake duct (106) and the air discharge duct (116) regulate a circulation speed (via 104) of the first (the flow of air through 112) and second (the vertical air flow formed from the discharge of 208 through 114) air flows by controlling a first pressure (the pressure within 106, via 104; “distribution unit 104 blows the air supply though at least one main supply line 106 and may pressurize the at least one main supply line 106 to a level above the internal pressure of the at least one cabinet”, Col. 3, lines 6-9) to push (as illustrated by the air flow arrows in Figure 2) the first vertical air flow (the flow of air through 112) and a second pressure (the pressure within 116, via the negative pressure created by 104 downstream of 104 and the positive pressure created by the internal air unit in each rack to draw the air through 208 and into 114) to draw in (as illustrated by the air flow arrows in Figure 2) the second vertical air flow (the vertical air flow formed from the discharge of 208 through 114). Allowable Subject Matter Claims 4, 5, 6, and 7 are objected to as being dependent on a rejected base claim, but would be allowable if rewritten in independent form including all of the limitations of the base claim and any intervening claims. Regarding Claims 4 and 6, Roth teaches the claimed invention except the air discharge pipe is designed with a uniform divided bottom area for the discharge splitter to consistently maintain the second vertical air flow inside the air discharge pipe. There is no motivation in the prior art to design the air discharge pipe with a uniformly divided bottom area for the discharge splitter. Claims 5 and 7 depend from Claims 4 and 6, respectively. Conclusion The prior art made of record and not relied upon is considered pertinent to applicant's disclosure and is provided in the Notice of References Cited. The following prior art teaches related cooling devices: Patrick et al. (U.S. Patent No. 10,299,410): see Figure 1 Farshchian et al. (U.S. Pre-Grant Publication No. 2016/0330873): see Figure 1 Sun (U.S. Patent No. 8,345,419): see Figures 1 and 4 Khalili (U.S. Patent No. 7,886,555): see Figure 1 Khalili et al. (U.S. Pre-Grant Publication No. 2009/0126293): see Figure 2 Kundapur (U.S. Pre-Grant Publication No. 2008/0239659): see Figure 1 Storck et al. (U.S. Patent No. 6,616,524): see Figure 4 Any inquiry concerning this communication or earlier communications from the examiner should be directed to DANA K TIGHE whose telephone number is (571)272-9476. The examiner can normally be reached on Monday - Friday 8:00 - 4:00. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Helena Kosanovic, can be reached on 571-272-9059. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of an application may be obtained from the Patent Application Information Retrieval (PAIR) system. Status information for published applications may be obtained from either Private PAIR or Public PAIR. Status information for unpublished applications is available through Private PAIR only. For more information about the PAIR system, see http://pair-direct.uspto.gov. Should you have questions on access to the Private PAIR system, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative or access to the automated information system, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /DANA K TIGHE/Examiner, Art Unit 3762 /AVINASH A SAVANI/Primary Examiner, Art Unit 3762
Read full office action

Prosecution Timeline

Oct 11, 2024
Application Filed
Oct 19, 2026
Non-Final Rejection mailed — §102 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12787184
HOUSING HAVING VENTILATION MEMBER ARRANGED THEREIN, AND ELECTRONIC DEVICE COMPRISING SAME
3y 1m to grant Granted Nov 03, 2026
Patent 12779937
AIR CONDITIONER FOR VEHICLE
2y 11m to grant Granted Nov 03, 2026
Patent 12779931
VEHICLE AIR CONDITIONING SYSTEM
2y 5m to grant Granted Nov 03, 2026
Patent 12774824
DUCT TYPE AIR CONDITIONING VENTILATION SYSTEM
2y 10m to grant Granted Oct 27, 2026
Patent 12766913
DUCT APPARATUS FOR A MOBILITY VEHICLE
2y 11m to grant Granted Oct 20, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
76%
Grant Probability
93%
With Interview (+16.9%)
3y 3m (~1y 2m remaining)
Median Time to Grant
Low
PTA Risk
Based on 672 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month