Prosecution Insights
Last updated: October 25, 2026
Application No. 18/937,767

X-Ray Image Feature Detection And Registration Systems And Methods

Non-Final OA §103
Filed
Nov 05, 2024
Priority
Nov 18, 2015 — provisional 62/257,213 +4 more
Examiner
GILLIARD, DELOMIA L
Art Unit
2668
Tech Center
2600 — Communications
Assignee
LightLab Imaging Inc.
OA Round
1 (Non-Final)
90%
Grant Probability
Favorable
1-2
OA Rounds
0m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 90% — above average
90%
Career Allowance Rate
996 granted / 1111 resolved
+27.6% vs TC avg
Moderate +10% lift
Without
With
+10.3%
Interview Lift
resolved cases with interview
Fast prosecutor
2y 0m
Avg Prosecution
28 currently pending
Career history
1140
Total Applications
across all art units

Statute-Specific Performance

§101
8.3%
-31.7% vs TC avg
§103
52.0%
+12.0% vs TC avg
§102
16.2%
-23.8% vs TC avg
§112
11.2%
-28.8% vs TC avg
Black line = Tech Center average estimate • Based on career data from 1111 resolved cases

Office Action

§103
Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Claim Rejections - 35 USC § 103 In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. The factual inquiries for establishing a background for determining obviousness under 35 U.S.C. 103 are summarized as follows: 1. Determining the scope and contents of the prior art. 2. Ascertaining the differences between the prior art and the claims at issue. 3. Resolving the level of ordinary skill in the pertinent art. 4. Considering objective evidence present in the application indicating obviousness or nonobviousness. This application currently names joint inventors. In considering patentability of the claims the examiner presumes that the subject matter of the various claims was commonly owned as of the effective filing date of the claimed invention(s) absent any evidence to the contrary. Applicant is advised of the obligation under 37 CFR 1.56 to point out the inventor and effective filing dates of each claim that was not commonly owned as of the effective filing date of the later invention in order for the examiner to consider the applicability of 35 U.S.C. 102(b)(2)(C) for any potential 35 U.S.C. 102(a)(2) prior art against the later invention. Claim(s) 1-4, 7-9, 15-17 and 20 is/are rejected under 35 U.S.C. 103 as being unpatentable over US 2014/0094689 to Cohen et al., hereinafter, “Cohen” in view of US 2012/0099774 A1 to Akcakaya et al., hereinafter “Akcakaya”. Claim 1. (new) Cohen teaches A method, comprising: [Abstract] receiving, by one or more processors, a set of extraluminal image frames of extraluminal blood vessels [0031] at least one processor configured to receive from the one or more extraluminal imaging devices: [0032] a first set of extraluminal images of the lumen detecting, by the one or more processors, one or more anatomic features on one or more frames of the set of extraluminal image frames; [0480] Examples of the anatomical structure to which the aforementioned co-registration of extraluminal and endoluminal images may be applied include a coronary vessel, a coronary lesion, a vessel, a vascular lesion, a lumen, a luminal lesion, and/or a valve Cohen fails to explicitly teach clustering, by the one or more processors based on the detected one or more anatomic features. Akcakaya, in the field of analyzing medical images teaches clustering, by the one or more processors based on the detected one or more anatomic features, one or more extraluminal image frames of the set, FIG. 1 element 106 [0008] … an acquired image data set. An improved compressed sensing reconstruction method is provided for the reconstruction of target images from undersampled image data [0037] To utilize low-rankedness of clusters, each N.sub.b.times.N.sub.b image block in the similarity clusters… each image block has similar anatomical features wherein a cluster corresponds to an anatomic feature detected in two or more extraluminal image frames of the set; [0037] To utilize low-rankedness of clusters, each N.sub.b.times.N.sub.b image block in the similarity clusters… each image block has similar anatomical features and performing, by the one or more processors, interframe registration of extraluminal image frames using the clusters of the one or more extraluminal image frames. [0028] if more than N.sub.cluster image blocks are matched to the reference image block, only those blocks with the highest degree of similarity in the cluster are considered for further processing. Examiner understands interframe registration to be aligning/matching the cluster image blocks to another cluster image block. [0037] To utilize low-rankedness of clusters, each N.sub.b.times.N.sub.b image block in the similarity clusters… each image block has similar anatomical features Thus, before the effective filing date of the present application, it would have been obvious to one of ordinary skill in the art to combine the teachings of Cohen with the teachings of Akcakaya [0007] to provide a method for magnetic resonance image reconstruction that includes the scan time reduction benefits of CS techniques, but that is robust to inter- and intra-patient variabilities without the need for separately acquired training data. Rationale applies to claims 2-4, 7-9, 15-17 and 20. Claim 2. (new) Cohen teaches The method of claim 1, wherein the one or more anatomic features comprise at least one of a bifurcation, a bend, angles with respect to a vessel centerline, a normalized arc length of the bifurcation, an average image intensity along bifurcations branches, bifurcation scale, bifurcation width, absolute angle on the one or more frames of the set, or bifurcation lumen shape. [0330] features include anatomical features, such as bifurcations, lesions, calcifications, etc Claim 3. (new) Cohen teaches The method of claim 1, wherein detecting the one or more anatomic features further comprises applying, by the one or more processors, one or more filters to the one or frames of the set. [0341] Identifying features using image processing techniques (e.g., detecting vesselness, using a hessian filter, using corner detection, using directional filters, etc.) Claim 4. (new) Cohen teaches The method of claim 3, wherein the one or more filters includes at least one of a Hessian based filter, a shadow removal filter, a rib filter, a temporal filter, or a vessel crossing filter. [0341] Identifying features using image processing techniques (e.g., detecting vesselness, using a hessian filter, using corner detection, using directional filters, etc.) Claim 7. (new) Akcakaya teaches The method of claim 1, further comprising generating, by the one or more processors, one or more distance measurements between two or more clusters. [0025-0026] measures the distance between clusters Claim 8. (new) Akcakaya teaches The method of claim 7, wherein a distance metric of the one or more distance measurements is a Euclidean metric. Akcakaya [0025-0026] distance measure of two blocks (clusters) of a voxel location. Claim 9. (new) Akcakaya teaches The method of claim 7, further comprising validating, by the one or more processors, whether the one or more detected anatomic features are present in two or more extraluminal image frames. Akcakaya [0028] if more than N.sub.cluster image blocks are matched to the reference image block, only those blocks with the highest degree of similarity in the cluster are considered for further processing. Examiner interprets matching using a threshold of similarity to be validating. Claim 15. (new) Reviewed and analyzed in the same way as claim 1. See the above analysis and rationale. Claim 16. (new) Reviewed and analyzed in the same way as claim 3. See the above analysis and rationale. Claim 17. (new) Reviewed and analyzed in the same way as claim 7. See the above analysis and rationale. Claim 20. (new) Reviewed and analyzed in the same way as claim 1. See the above analysis and rationale. Claim(s) 5-6, 14 and 18 is/are rejected under 35 U.S.C. 103 as being unpatentable over US 2014/0094689 to Cohen et al., hereinafter, “Cohen” in view of US 2012/0099774 A1 to Akcakaya et al., hereinafter “Akcakaya” and in further view of US 2014/0270436 A1 to Dascal et al., hereinafter, “Dascal”. Claim 5. (new) Cohen fails to explicitly teach generating, by the one or more processors a plurality of centerlines from imaged regions of blood vessels. Dascal, in the field of analyzing medical images, teaches the method of claim 1, further comprising: generating, by the one or more processors a plurality of centerlines from imaged regions of blood vessels; [0024] generating a vessel centerline for the plurality of frames of angiography image data… tracking…along one or more vessel centerlines generating by the one or more processors, a binary image for a plurality of extraluminal image frames of the set of extraluminal image frames for which centerlines have been generated; [0122] For each angiography image, a set of preprocessing steps is applied to create a binary map and generating, by the one or more processors, a skeleton image frame for each extraluminal image frame of the plurality of extraluminal image frames using the binary images of each such extraluminal image frame [0124] a distance map is a tool that is used to determine the vessel skeleton from the binary map [0128] A binary image generated from the Hessian image can be used to generate skeletons in the angiography image as shown in FIG. 7B and a centerline generated from blood vessel regions imaged in each such extraluminal image frame. [0127] skeletons can be used for detecting and generating a smooth vessel centerline Thus, before the effective filing date of the present application, it would have been obvious to one of ordinary skill in the art to combine the teachings of Cohen with the teachings of Dascal [0005] to alleviate challenges regarding real time co-registration of intravascular image data and angiography image data. Claim 6. (new) Cohen fails to explicitly teach anatomic features are detected one or more anatomic features are detected on one or more frames of a group of skeleton image frames. Dascal, in the field of analyzing medical images, teaches the method of claim 1, wherein the detected one or more anatomic features are detected on one or more frames of a group of skeleton image frames. Dascal [0127] generating skeletons to detect anatomic features like side branches and vessel geometry is implemented during preprocessing of the angiography images 160d. Skeletons can be used for detecting anatomical features Thus, before the effective filing date of the present application, it would have been obvious to one of ordinary skill in the art to combine the teachings of Cohen with the teachings of Dascal [0005] to alleviate challenges regarding real time co-registration of intravascular image data and angiography image data. Claim 14. (new) Cohen fails to explicitly teach a contrast cloud region in the set of extraluminal image frames. Dascal, in the field of analyzing medical images, teaches the method of claim 1, further comprising: identifying, by the one or more processors, a contrast cloud region in the set of extraluminal image frames; Dascal [0087] a cloud of contrast agent and determining, by the one or more processors, a subset of the set of extraluminal image frames excluding regions of the set of extraluminal image frames that include the identified contrast cloud region. Dascal [0087] In some of the angiography frames, the marker bands appear blurred/faint due to fast pullback motion combined with fast cardiac motion. Thus, before the effective filing date of the present application, it would have been obvious to one of ordinary skill in the art to combine the teachings of Cohen with the teachings of Dascal [0005] to alleviate challenges regarding real time co-registration of intravascular image data and angiography image data. Claim 18. (new) Reviewed and analyzed in the same way as claim 5. See the above analysis and rationale. Allowable Subject Matter Claims 10-13 and 19 are objected to as being dependent upon a rejected base claim, but would be allowable if rewritten in independent form including all of the limitations of the base claim and any intervening claims. Conclusion The prior art made of record and not relied upon is considered pertinent to applicant's disclosure. US 2017/0140531 A1 to Dascal et al., US 2014/0094691 A1 to Steinberg et al. Any inquiry concerning this communication or earlier communications from the examiner should be directed to DELOMIA L GILLIARD whose telephone number is (571)272-1681. The examiner can normally be reached 8am-5pm. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, John Villecco can be reached at (571) 272-7319. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /DELOMIA L GILLIARD/Primary Examiner, Art Unit 2661
Read full office action

Prosecution Timeline

Nov 05, 2024
Application Filed
Jun 10, 2026
Response after Non-Final Action
Oct 05, 2026
Non-Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12770295
EPIPOLAR CONSTRAINT-BASED CROSS-CAMERA CALIBRATION VALIDATION
2y 7m to grant Granted Oct 20, 2026
Patent 12770270
TECHNIQUES FOR ROBUST REAL-TIME MULTIPLE-OBJECT TRACKING WITH DETECTION PROPAGATION AND PER-CLASS OPTIMIZATION
2y 6m to grant Granted Oct 20, 2026
Patent 12762824
METHOD AND SYSTEM FOR ADAPTIVE CORNER DETECTION USING DYNAMIC VISION SENSORS
2y 8m to grant Granted Oct 13, 2026
Patent 12764346
COMPRESSING AND DECOMPRESSING IMAGE DATA USING COMPACTED REGION TRANSFORMS
2y 2m to grant Granted Oct 13, 2026
Patent 12755554
BELIEF PROPAGATION FOR RANGE IMAGE MAPPING IN AUTONOMOUS MACHINE APPLICATIONS
2y 7m to grant Granted Oct 06, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
90%
Grant Probability
99%
With Interview (+10.3%)
2y 0m (~0m remaining)
Median Time to Grant
Low
PTA Risk
Based on 1111 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month