Prosecution Insights
Last updated: November 04, 2026
Application No. 18/942,834

ENHANCING EFFICIENCY OF A SWITCHING CONVERTER

Final Rejection §102§103
Filed
Nov 11, 2024
Priority
Nov 24, 2023 — IN 202341079957
Examiner
CHOI, SEUNG HO
Art Unit
2838
Tech Center
2800 — Semiconductors & Electrical Systems
Assignee
Shaoxing Yuanfang Semiconductor Co. Ltd.
OA Round
2 (Final)
100%
Grant Probability
Favorable
3-4
OA Rounds
1m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 100% — above average
100%
Career Allowance Rate
22 granted / 22 resolved
+32.0% vs TC avg
Minimal +0% lift
Without
With
+0.0%
Interview Lift
resolved cases with interview
Fast prosecutor
2y 1m
Avg Prosecution
18 currently pending
Career history
51
Total Applications
across all art units

Statute-Specific Performance

§101
2.8%
-37.2% vs TC avg
§103
56.9%
+16.9% vs TC avg
§102
37.5%
-2.5% vs TC avg
§112
2.8%
-37.2% vs TC avg
Black line = Tech Center average estimate • Based on career data from 22 resolved cases

Office Action

§102 §103
DETAILED ACTION This Office action is in response to the application filed on 11 November 2024. Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Priority Receipt is acknowledged of certified copies of papers required by 37 CFR 1.55. Response to argument Applicant's arguments, see pg. 9-11, filed on 01 September 2026, with respect to the rejection of claims 1, 7, 13 have been fully considered but they are not persuasive. In response to applicant’s argument, “Thus, Global PWM/PFM Controller of Singh generates V ctrl based on Load Current (or the resulting Vout), and Control State Machine thereafter generates phase shifted versions of the control signal V ctr 1. It may be appreciated that the Load Current (and Vout) is the result of operation of several Phases together. The use of such voltage/load current in Singh cannot be reasonably equated to the claimed use of magnitudes of individual inductor currents of corresponding power stages for determining the frequency of phase control signals.”, examiner respectfully disagrees because Singh cited magnitudes of individual inductor currents in “Fig. 2 Proposed imbalanced multi-phase buck converter, i.e. all phases have different inductor, switching frequency, controller, and load current share”. Accordingly, applicant’s arguments regarding the claims 1,7,13 are not persuasive, and the rejection is maintained. Applicant's arguments, see pg. 11-12, filed on 01 September 2026, with respect to the rejection of claim 2 have been fully considered but they are not persuasive. In response to applicant’s argument, “Figure 1 of Singh depicts each Phase connecting to Control State-Machine. However, it is disclosed in Section II on Page 929 that, "At intermediate and heavy loads, the Control State Machine activates more phases based on the load and ensures equal current distribution among the phases by observing the current in each phase and skipping switching cycles as needed." Thus, the Control State-Machine of Singh is disclosed to observe current in each phase merely for ensuring equal current distribution among the phases. Such an operation cannot be equated to the claimed determination of the frequency (of phase control signals of power stages) as an optimal frequency at which the power stages operate with optimal power efficiency.”, examiner respectfully disagrees because Singh also cited in paragraph II; “Pulse Frequency Modulation (PFM) control is employed to scale the switching losses with the load to maintain high efficiency”. Under broadest reasonable interpretation (BRI), the examiner understands words cited in paragraph II means PFM operates with an optimal frequency at which the power stages operate with optimal power efficiency. Accordingly, applicant’s arguments regarding the claim 2 are not persuasive, and the rejection is maintained. Applicant's arguments, see pg. 11-12, filed on 01 September 2026, with respect to the rejection of claim 3 have been fully considered but they are not persuasive. In response to applicant’s argument, “The First Non-Final Office Action relies on the first paragraph of Section IV.A on page# 2921 of Costa in rejecting previously examined claim 3. However, it is respectfully noted that the disclosure there merely explains that the PWM modulator performance is sought to be increased "in terms of maximum switching frequency, duty-cycle precision, and area consumption." There is simply no disclosure or suggestion that maximum switching frequency is employed in the claimed conditions.”, costa cited in paragraph IV; “This configuration is used in the modern digital control of SMPSs to increase the PWM modulator performances in terms of maximum switching frequency, duty-cycle precision, and area consumption.” Under broadest reasonable interpretation (BRI), the examiner understands words cited in paragraph IV means controller determined and used maximum switching frequency for increased PWM modulator performance. Accordingly, applicant’s arguments regarding the claim 3 are not persuasive, and the rejection is maintained. Claim Rejections - 35 USC § 102 In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale, or otherwise available to the public before the effective filing date of the claimed invention. (a)(2) the claimed invention was described in a patent issued under section 151, or in an application for patent published or deemed published under section 122(b), in which the patent or application, as the case may be, names another inventor and was effectively filed before the effective filing date of the claimed invention. Claims 1,2,4,13,14 are rejected under 35 U.S.C. 102(a)(1) as being anticipated by Manmeet Singh et. al (2019 IEEE 62nd International Midwest Symposium on Circuits and Systems; hereafter “Singh”). -Regarding claim 1: Singh discloses: PNG media_image1.png 456 666 media_image1.png Greyscale A multi-phase switching converter (Fig. 1) to provide a regulated supply voltage from an input voltage (Fig. 1; Vin), said multi-phase switching converter comprising: a plurality of power stages (Fig. 1; Phase(1)..(n)), each power stage to drive a corresponding inductor (Fig. 1; L(1)…) to cause flow of a corresponding inductor-current according to a respective phase control signal (Fig. 1; Ctrl), wherein said corresponding inductor-currents from each of said plurality of power stages together constitute a load-current of said multi-phase switching converter (Fig. 1; Each inductor current constitutes load-current to Vout.); and a phase controller to identify respective magnitude of each inductor-current of corresponding power stage of said plurality of power stages (Fig. 2; Proposed imbalanced multi-phase buck converter, i.e. all phases have different inductor, switching frequency, controller, and load current share. local current mode controller coupled with inductor current/I(1), Fig. 3, table I, and paragraph IV; “Based on the 1-µH inductor’s saturation current in table I, this approach needs 12 phases to support 12-A maximum load and yields the best efficiency up to 0.7-A,”), and to determine a frequency of said phase control signals based on the identified magnitudes of said inductor-currents (Fig. 1; Global PWM/PFM controller determines a frequency based on inductor current at node Vout. , Fig. 2; Proposed imbalanced multi-phase buck converter, i.e. all phases have different inductor, switching frequency, controller, and load current share.), and to generate said phase control signals with said frequency. -Regarding claim 13: Singh discloses: A phase controller for generating phase control signals (Fig. 1; Ctrl) in a multi-phase switching converter (Fig. 1), said phase controller to: receive magnitudes of corresponding inductor-currents (Fig. 1; currents through L(1)…) from a plurality of power stages (Fig. 1; Phase(1)..(n)) of said multi-phase switching converter, wherein said corresponding inductor-currents (Fig. 1; currents through L(1)…) from said plurality of power stages together constitute a load-current of said multi-phase switching converter (Fig. 1; Each inductor current constitutes load-current to Vout.); determine, based on said magnitudes of said corresponding inductor-currents, a frequency at which said phase control signals are to be generated (Fig. 1; Global PWM/PFM controller determines a frequency based on inductor current at node Vout.); and generate said phase control signals with said determined frequency and provide said phase control signals to said plurality of power stages. -Regarding claim 2: Singh discloses: The multi-phase switching converter of claim 1, wherein each power stage of said plurality of power stages sends information on the corresponding inductor-current to said phase controller (Fig. 1; Control State-Machine receives inductor current information from each power stage.) to enable said phase controller to identify said magnitudes (Fig. 2; local current mode controller coupled with inductor current/I(1), Fig. 3, table I, and paragraph IV; “Based on the 1-µH inductor’s saturation current in table I, this approach needs 12 phases to support 12-A maximum load and yields the best efficiency up to 0.7-A,”), wherein said phase controller determines said frequency as an optimal frequency at which said plurality of power stages operate with optimal power efficiency (paragraph II; “Pulse Frequency Modulation (PFM) control is employed to scale the switching losses with the load to maintain high efficiency”). -Regarding claim 14: Singh discloses: The phase controller of claim 13, wherein each power stage of said plurality of power stages sends information on the corresponding inductor-current to said phase controller (Fig. 1; Control State-Machine receives inductor current information from each power stage.), wherein said frequency is determined as an optimal frequency at which said plurality of power stages operate with optimal power efficiency (paragraph II; “Pulse Frequency Modulation (PFM) control is employed to scale the switching losses with the load to maintain high efficiency”). -Regarding claim 4: Singh discloses: The multi-phase switching converter of claim 3, wherein said phase controller generates said phase control signals with said frequency and a duty-cycle determined by at least the magnitude of said regulated supply voltage (Fig. 1; Global PWM/PFM controller generates frequency and duty cycle based on regulated supply voltage-load voltage Vout.) and the magnitude of said input voltage (I would say that it is common to use input voltage as in reference papers I attached.). Claims 3, 15 and 16 are rejected under 35 U.S.C. 103 as being unpatentable over Manmeet Singh et. al (2019 IEEE 62nd International Midwest Symposium on Circuits and Systems) as applied to claims 2,14 above, and further in view of A. Costabeber et.al (2009 35th Annual Conference of IEEE Industrial Electronics; hereafter “Costa”). -Regarding claim 3: Singh discloses: The multi-phase switching converter of claim 2, wherein said phase controller is designed to select said frequency from among a set of frequencies at which said plurality of power stages are operable at (Fig. 2; Proposed imbalanced multi-phase buck converter, i.e. all phases have different inductor, switching frequency, controller, and load current share., paragraph III; “the imbalanced multi-phase design shown in Fig. 2 with “n” phases is proposed. Unlike balanced designs, each phase has its own inductor, switching frequency, and local current-mode controller,”). However, Singh does not disclose frequency determination at each situation in multi-phase switching converter. Costa, in the same field of endeavor, discloses: The multi-phase switching converter of claim 2, phase controller determines said frequency to be a maximum frequency among said set of frequencies in a first duration (paragraph IV; “This configuration is used in the modern digital control of SMPSs to increase the PWM modulator performances in terms of maximum switching frequency, duty-cycle precision, and area consumption.”) if at least one of a higher phase-count-demand, undershoot and over-current is detected, wherein said higher phase count demand refers to a condition wherein a load-current drawn from a rail in a period requires a higher number of power stages to be in active mode than in an immediately preceding period, wherein said undershoot is a decrease in magnitude of said regulated supply voltage wherein said magnitude of said regulated supply voltage falls below an allowed lower limit for said regulated supply voltage, and wherein said over-current is a condition wherein inductor-current corresponding to a power stage is in excess of a maximum limit (I would say that three types of above action are well-known to be related with the performance of PWM controller, and the increasing of PWM performance is well-within the skill of the person of ordinary skill in the art. I would then come up with a motivation to choose the increasing of PWM performance and give that as the rationale.). It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the device described in Singh such that a commonly used PWM performance control technique described in Costa is applied to the multi-phase switching converter. Doing so allows for improving the efficiency of the multi-phase switching converter. -Regarding claim 15: Singh discloses: The multi-phase switching converter of claim 2, wherein said phase controller is designed to select said frequency from among a set of frequencies at which said plurality of power stages are operable at (Fig. 2, paragraph III; “the imbalanced multi-phase design shown in Fig. 2 with “n” phases is proposed. Unlike balanced designs, each phase has its own inductor, switching frequency, and local current-mode controller,”). However, Singh does not disclose frequency determination at each situation in multi-phase switching converter. Costa, in the same field of endeavor, discloses: The phase controller of claim 14, determine said frequency to be a maximum frequency among said set of frequencies in a first duration (paragraph IV; “This configuration is used in the modern digital control of SMPSs to increase the PWM modulator performances in terms of maximum switching frequency, duty-cycle precision, and area consumption.”) if at least one of a higher phase-count-demand, undershoot and over-current is detected, wherein said higher phase count demand refers to a condition wherein a load-current drawn from a rail of said multi-phase switching converter in a period requires a higher number of power stages to be in active mode than in an immediately preceding period, wherein said undershoot is a decrease in magnitude of a regulated supply voltage provided by a multi-phase switching converter, wherein said magnitude of said regulated supply voltage falls below an allowed lower limit for said regulated supply voltage, and wherein said over-current is a condition wherein inductor-current corresponding to a power stage is in excess of a maximum limit (I would say that three types of above action are well-known to be related with the performance of PWM controller, and the increasing of PWM performance is well-within the skill of the person of ordinary skill in the art. I would then come up with a motivation to choose the increasing of PWM performance and give that as the rationale.). It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the device described in Singh such that a commonly used PWM performance control technique described in Costa is applied to the multi-phase switching converter. Doing so allows for improving the efficiency of the multi-phase switching converter. -Regarding claim 16: Singh discloses: The phase controller of claim 15, wherein said phase controller to generate said phase control signals with said frequency and a duty-cycle determined by at least the magnitude of said regulated supply voltage (Fig. 1; Global PWM/PFM controller generates frequency and duty cycle based on regulated supply voltage-load voltage Vout.) and the magnitude of said input voltage (I would say that it is common to use input voltage as in reference papers I attached.). Claims 5 and 17 is rejected under 35 U.S.C. 103 as being unpatentable over Manmeet Singh et. al (2019 IEEE 62nd International Midwest Symposium on Circuits and Systems) as applied to claims 4,16 above, and further in view of Yu-Ping Huang et.al (2011 IEEE International Symposium of Circuits and Systems; hereafter “Yu”). -Regarding claim 5: However, Singh does not disclose a phase controller in multi-phase switching converter. Yu, in the same field of endeavor, discloses: The multi-phase switching converter of claim 4, wherein each of said plurality of power stages generates a current-sense signal representing a magnitude of said corresponding inductor current (Fig. 2; current sense signal to current sensor signal from each power stage), wherein said phase controller comprises: a telemetry block to receive said current-sense signals and generate digital values (Fig. 2; current sensor doing this job) representing said magnitudes; a frequency determination block coupled to receive said digital values and to output said frequency (Fig. 2; PWM generator and COMP, I would say that it is common to use PWM/PFM for frequency determination as in reference papers I attached.); and a control block coupled to receive said frequency, and to generate said phase control signals with said frequency and said duty-cycle (Fig. 2; PWM generator). It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the device described in Singh and Costa such that a commonly used phase controller described in Yu is applied to the multi-phase switching converter. Doing so allows for improving the efficiency of the multi-phase switching converter. -Regarding claim 17: Singh discloses: The phase controller of claim 16, wherein each of said plurality of power stages generates a current-sense signal representing a magnitude of said corresponding inductor-current (Fig. 2; local current mode controller coupled with inductor current/I(1), Fig. 3, table I, and paragraph IV; “Based on the 1-µH inductor’s saturation current in table I, this approach needs 12 phases to support 12-A maximum load and yields the best efficiency up to 0.7-A,”) , wherein said However, Singh does not disclose a phase controller in multi-phase switching converter. Yu, in the same field of endeavor, discloses: The phase controller of claim 16a telemetry block to receive said current-sense signals and generate digital values representing said magnitudes (Fig. 2; current sensor doing this job); a frequency determination block coupled to receive said digital values and to output said frequency (Fig. 2; PWM generator and COMP, I would say that it is common to use PWM/PFM for frequency determination as in reference papers I attached.); and a control block coupled to receive said frequency, and to generate said phase control signals with said frequency and said duty-cycle (Fig. 2; PWM generator). It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the device described in Singh and Costa such that a commonly used phase controller described in Yu is applied to the multi-phase switching converter. Doing so allows for improving the efficiency of the multi-phase switching converter. Claims 6 and 18 are rejected under 35 U.S.C. 103 as being unpatentable over Manmeet Singh et. al (2019 IEEE 62nd International Midwest Symposium on Circuits and Systems), A. Costabeber et.al (2009 35th Annual Conference of IEEE Industrial Electronics), and Yu-Ping Huang et.al (2011 IEEE International Symposium of Circuits and Systems) as applied to claim 5 above, and further in view of D. Neumayr et.al (2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia ; hereafter “Neumayr”). -Regarding claim 6: However, Singh, Costa, and Yu do not disclose a look-up table in multi-phase switching converter. Neumayr, in the same field of endeavor, discloses: The multi-phase switching converter of claim 5, wherein said frequency determination block comprises a look-up table (LUT) which maps each combination of different combinations of magnitudes of said inductor-currents to corresponding frequency of said set of frequencies as said optimal frequency (Fig. 8 a and b), wherein said frequency is determined by examining said LUT. It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the device described in Singh, Costa and Yu such that a commonly used look-up table described in Neumayr is applied to the multi-phase switching converter. Doing so allows for improving the efficiency of the multi-phase switching converter. -Regarding claim 18: However, Singh, Costa, and Yu do not disclose a phase controller in multi-phase switching converter. Neumayr, in the same field of endeavor, discloses: The phase controller of claim 17, wherein said frequency determination block comprises a look-up table (LUT) which maps each combination of different combinations of magnitudes of said inductor-currents to corresponding frequency of said set of frequencies as said optimal frequency (Fig. 8 a and b), wherein said frequency is determined by examining said LUT. It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to modify the device described in Singh, Costa and Yu such that a commonly used look-up table described in Neumayr is applied to the multi-phase switching converter. Doing so allows for improving the efficiency of the multi-phase switching converter. -Regarding claim 7-12: For method claims 7-12, note that under MPEP 2112.02, the principles of inherency, if a prior art device, in its normal and usual operation, would necessarily perform the method claimed, then the method claimed will be considered to be anticipated by the prior art device. When the prior art is the same as a device described in the specification for carrying out the claimed method, it can be assumed the device “1 inherently performs the claimed process. In re King, 801 F.2d 1324, 231 UPSQ 136 (Fed Cir. 1986). Therefore, the previous rejections based on the apparatus will not be repeated. Conclusion THIS ACTION IS MADE FINAL. Applicant is reminded of the extension of time policy as set forth in 37 CFR 1.136(a). A shortened statutory period for reply to this final action is set to expire THREE MONTHS from the mailing date of this action. In the event a first reply is filed within TWO MONTHS of the mailing date of this final action and the advisory action is not mailed until after the end of the THREE-MONTH shortened statutory period, then the shortened statutory period will expire on the date the advisory action is mailed, and any nonprovisional extension fee (37 CFR 1.17(a)) pursuant to 37 CFR 1.136(a) will be calculated from the mailing date of the advisory action. In no event, however, will the statutory period for reply expire later than SIX MONTHS from the mailing date of this final action. Any inquiry concerning this communication or earlier communications from the examiner should be directed to SEUNG HO CHOI whose telephone number is (571)272-8188. The examiner can normally be reached Monday-Thursday, 7:30 AM - 5:30 PM ET. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Crystal Hammond can be reached at 571-270-1682. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /SEUNG HO CHOI/Examiner, Art Unit 2838 /CRYSTAL L HAMMOND/ Supervisory Primary Examiner, Art Unit 2838
Read full office action

Prosecution Timeline

Nov 11, 2024
Application Filed
Jun 08, 2026
Non-Final Rejection mailed — §102, §103
Sep 01, 2026
Response Filed
Oct 20, 2026
Final Rejection mailed — §102, §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12771233
DRIVING DEVICE AND POWER CONVERTER
2y 7m to grant Granted Oct 20, 2026
Patent 12754452
POWER SOURCE DEVICE, ELECTROPHORESIS DEVICE, POWER SOURCE DEVICE CONTROL METHOD, AND ELECTROPHORESIS DEVICE CONTROL METHOD
3y 6m to grant Granted Oct 06, 2026
Patent 12749977
METHOD FOR CONTROLLING A NON-INVERTING BUCK BOOST DC-DC CONVERTER AND CORRESPONDING CONVERTER
1y 12m to grant Granted Sep 29, 2026
Patent 12744453
CURRENT LIMITING CIRCUIT
2y 6m to grant Granted Sep 22, 2026
Patent 12726117
VOLTAGE BOOSTER AND VOLTAGE BOOSTER SYSTEM
2y 5m to grant Granted Sep 01, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
100%
Grant Probability
99%
With Interview (+0.0%)
2y 1m (~1m remaining)
Median Time to Grant
Moderate
PTA Risk
Based on 22 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month