Application No. 18/948,914

MEDICAL DEVICES WITH RE-JOINABLE HOUSINGS

Non-Final OA §102
Filed
Nov 15, 2024
Priority
Nov 17, 2023 — provisional 63/600,627
Examiner
IGBOKO, CHIMA U
Art Unit
3771
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Stryker Corporation
OA Round
1 (Non-Final)
79%
Grant Probability
Favorable
1-2
OA Rounds
1y 6m
Est. Remaining
99%
With Interview

Examiner Intelligence

Grants 79% — above average
79%
Career Allowance Rate
337 granted / 429 resolved
+8.6% vs TC avg
Strong +40% interview lift
Without
With
+39.8%
Interview Lift
resolved cases with interview
Typical timeline
3y 5m
Avg Prosecution
35 currently pending
Career history
468
Total Applications
across all art units

Statute-Specific Performance

§101
0.6%
-39.4% vs TC avg
§103
49.0%
+9.0% vs TC avg
§102
22.4%
-17.6% vs TC avg
§112
25.2%
-14.8% vs TC avg
Black line = Tech Center average estimate • Based on career data from 429 resolved cases

Office Action

§102
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Election/Restrictions Applicant’s election without traverse of Group I, claims 1-19 in the reply filed on 08/12/26 is acknowledged. Claims 20-29 withdrawn from further consideration pursuant to 37 CFR 1.142(b) as being drawn to a nonelected Group II, there being no allowable generic or linking claim. Election was made without traverse in the reply filed on 08/12/26. Claim Objections Claims 6 and 8 are objected to because of the following informalities: In claim 6, lines 3-4: “at least one other housing portion” should read “the at least one other housing portion”. In claim 8, line 1: “a plurality of primary joining portions” should read “a plurality of primary joining portions of the at least one primary joining portion”. In claim 8, line 2: “a plurality of secondary joining portions” should read “a plurality of secondary joining portions of the at least one secondary joining portion”. Appropriate correction is required. Claim Rejections - 35 USC § 102 The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale, or otherwise available to the public before the effective filing date of the claimed invention. Claims 1-9 and 11-19 are rejected under 35 U.S.C. 102(a)(1) as being anticipated by Fukuma (US 2011/0002497). Regarding claim 1, an invention relating to headphone device, Fukuma discloses (Figs. 1 & 7-8) a medical device (100) [Note, headphones are used by surgeons in procedures for informative purposes such as emitting a tone to a surgeon during an ophthalmic procedure to inform the surgeon that a proper depth has been achieved, headphones can be used in a surgical procedure for intracranial noise suppression, or headphones can provide music to a patient during medical procedure] comprising: at least two housing portions (see annotated figure below) joined together at at least one sacrificial joint (see annotated figure below) [i.e. joined prior to shortening of the band 104], wherein each housing portion comprises at least one secondary joining portion (see annotated figure below) configured for joining to at least one corresponding secondary joining portion (see annotated figure below) of at least one other housing portion for rejoining the two housing portions together after destructive breaking of the at least one sacrificial joint [i.e. removing links that make up the sacrificial joint and connecting free ends of links that make up at least one secondary joining portion and at least one corresponding secondary joining portion to rejoin the two housing portions] (Par. 0054, 0063, 0073, 0087). PNG media_image1.png 531 480 media_image1.png Greyscale PNG media_image2.png 428 459 media_image2.png Greyscale Regarding claim 2, Fukuma discloses the medical device of claim 1. Fukuma further discloses wherein the at least one sacrificial joint comprises at least one primary joining portion of each of the at least two housing portions, wherein the at least one primary joining portion of a housing portion is bonded to a corresponding primary joining portion of at least one other housing portion [i.e. bonded via elements 132 and 134; Figure 8] (see annotated figure below & Par. 0073). PNG media_image3.png 294 467 media_image3.png Greyscale Regarding claim 3, Fukuma discloses the medical device of claim 2. Fukuma further discloses wherein the at least one secondary joining portion meets the at least one primary joining portion at at least one separation portion [i.e. first side member 131 and the second side member 133 which engage when joint is assembled by connecting two links, see annotated figure below] (Fig. 8; Par. 0073). PNG media_image4.png 325 491 media_image4.png Greyscale Regarding claim 4, Fukuma discloses the medical device of claim 3. Fukuma further discloses wherein the at least one separation portion is configured so that the at least one primary joining portion can be removed upon disassembly of the at least two housing portions during reworking of the medical device, and the at least one secondary joining portion of a housing portion can be joined to the at least one corresponding secondary joining portion of at least one other housing portion to rejoin the at least two housing portions together (Par. 0064-0065). Regarding claim 5, Fukuma discloses the medical device of claim 2. Fukuma further discloses wherein a volume of an enclosure defined by the at least two housing portions (see annotated figure below) joined together is less when the primary joining portions are joined together than when the secondary joining portions are joined together (Par. 0064-0065) [Note, the volume would be less because removing links would decrease the cross-sectional area of the enclosure, and a decrease in area is correlative to a decrease in volume]. PNG media_image5.png 598 505 media_image5.png Greyscale Regarding claim 6, Fukuma discloses the medical device of claim 2. Fukuma further discloses (Fig. 8) wherein the at least one primary joining portion and the at least one secondary joining portion each comprise a flange [i.e. element 131 on each link is considered a flange, see annotated figure below], the flange comprising a joining surface for joining to a corresponding joining surface [i.e. the inside surface of element 133 that engages element 131] of a corresponding flange ( 133) of at least one other housing portion (see annotated figure below, Par. 0073). Note, the annotated figure shows where the corresponding joining surface would be on at least one other housing portion, and where the joining surface would be on at least one primary joining portion and where the joining surface would be on the at least one secondary joining portion. PNG media_image6.png 208 336 media_image6.png Greyscale Regarding claim 7, Fukuma discloses the medical device of claim 6. Fukuma further discloses wherein the joining surfaces of the primary and secondary joining portions are the same size [i.e. the primary and secondary joining surfaces are both the surface of element 131 on different links which have the same size] (Fig. 9D). Regarding claim 8, Fukuma discloses the medical device of claim 2. Fukuma further discloses wherein a plurality of primary joining portions are interleaved with a plurality of secondary joining portions [i.e. a plurality of primary joining portions would be elements 131 between a plurality of secondary joining portions which would be elements 133] (Par. 0069 & 0073). Regarding claim 9, Fukuma discloses the medical device of claim 8. Fukuma further discloses wherein the plurality of secondary joining portions of one of the at least two housing portions contact the plurality of secondary joining portions of another of the at least two housing portions when the primary joining portions are joined [i.e. primary joining portions when removed are joined and the plurality of secondary joining portions of each housing portion are joined to shorten the band] (see annotated figure below & Par. 0064-0065). PNG media_image7.png 466 452 media_image7.png Greyscale Regarding claim 11, Fukuma discloses the medical device of claim 1. Fukuma further discloses wherein the at least one secondary joining portion comprises a portion of an outer surface of the medical device when the at least two housing portions are joined together at the at least one sacrificial joint (see annotated figure below). PNG media_image8.png 560 792 media_image8.png Greyscale Regarding claim 12, Fukuma discloses the medical device of claim 1. Fukuma further discloses wherein the at least one secondary joining portion is located within an outer surface of the of the medical device when the at least two housing portions are joined together at the at least one sacrificial joint (see annotated figure below). PNG media_image9.png 564 884 media_image9.png Greyscale Regarding claim 13, Fukuma discloses the medical device of claim 1. Fukuma further discloses wherein the at least one secondary joining portions of the at least two housing portions are configured for being bonded together for rejoining the at least two housing portions together [i.e. elements 132 and 134 engaging to shorten band] (Fig. 8; Par. 0064-0065 & 0073). Regarding claim 14, Fukuma discloses the medical device of claim 1. Fukuma further discloses wherein the at least one sacrificial joint comprises at least one sacrificial portion configured to be removed prior to joining the secondary joining portions together (Par. 0064-0065). Regarding claim 15, Fukuma discloses the medical device of claim 14. Fukuma further discloses wherein the at least one sacrificial portion is configured to be removed by dissolving with a solvent [i.e. the links are formed of an elastic material such as a synthetic resin such as polypropylene which can be dissolved by a solvent, note the claim is not limited any particular solvent] (Par. 0056). Regarding claim 16, Fukuma discloses the medical device of claim 14. Fukuma further discloses wherein the secondary joining portions are bonded to the at least one sacrificial portion [i.e. the portions are connected via elements 132 and 134] (Par. 0064-0065 & 0073). Regarding claim 17, Fukuma discloses the medical device of claim 16. Fukuma further discloses wherein the secondary joining portions are configured for being bonded to at least one replacement sacrificial portion for rejoining the at least two housing portions together [i.e. links can be inserted between the secondary joining portions and connected to extend the band] (Par. 0066). Regarding claim 18, Fukuma discloses the medical device of claim 1. Fukuma further discloses wherein the medical device is a handheld device [i.e. the device can be carried by hand] (Par. 0061 & 0090). Regarding claim 19, Fukuma discloses the medical device of claim 1. Fukuma further discloses wherein the medical device comprises a handle (see annotated figure below) that is formed at least in part by at least a portion of the at least two housing portions [i.e. the device can be carried by hand] (Par. 0061 & 0090). PNG media_image10.png 439 506 media_image10.png Greyscale Allowable Subject Matter Claim 10 objected to as being dependent upon a rejected base claim, but would be allowable if rewritten in independent form including all of the limitations of the base claim and any intervening claims. Conclusion The prior art made of record and not relied upon is considered pertinent to applicant's disclosure. Prior art references Epstein (US 5,437,657), Gardner (US 5,570,426), and Booty, JR. et al. (US 2007/0112245) disclose headphones that are used for various medical purposes. Any inquiry concerning this communication or earlier communications from the examiner should be directed to Examiner Chima Igboko whose telephone number is (571)272-8422. The examiner can normally be reached on Monday-Friday 9:00am-6:00pm. If attempts to reach the examiner by telephone are unsuccessful, please contact the examiner’s supervisor, Jackie Ho, at (571) 272-4696. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of an application may be obtained from the Patent Application Information Retrieval (PAIR) system. Status information for published applications may be obtained from either Private PAIR or Public PAIR. Status information for unpublished applications is available through Private PAIR only. For more information about the PAIR system, see http://pair-direct.uspto.gov. Should you have questions on access to the Private PAIR system, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative or access to the automated information system, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /CHIMA U IGBOKO/ Examiner, Art Unit 3771
Read full office action

Prosecution Timeline

Nov 15, 2024
Application Filed
Sep 09, 2026
Non-Final Rejection mailed — §102 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12740860
DEVICES, SYSTEMS AND METHODS FOR DELIVERING A PROSTHETIC MITRAL VALVE AND ANCHORING DEVICE
2y 5m to grant Granted Sep 22, 2026
Patent 12721722
INTRAOCULAR LENS INJECTOR AND ITS DESIGN METHOD
3y 5m to grant Granted Sep 01, 2026
Patent 12708507
VISCOELASTIC SOFT TIP PLUNGER
2y 3m to grant Granted Aug 18, 2026
Patent 12702542
FOLDING DEVICE FOR INTRAOCULAR LENS INJECTOR
3y 8m to grant Granted Aug 11, 2026
Patent 12661218
HAPTIC OPTIC MANAGEMENT SYSTEM UTILIZING ROTATING CAMS
3y 7m to grant Granted Jun 23, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
79%
Grant Probability
99%
With Interview (+39.8%)
3y 5m (~1y 6m remaining)
Median Time to Grant
Low
PTA Risk
Based on 429 resolved cases by this examiner. Grant probability derived from career allowance rate.