COMPOSITE ENDOSCOPIC IMAGING DEVICE

Final Rejection §103
Filed
Dec 12, 2024
Priority
Jul 04, 2024 — provisional 63/667,712 +1 more
Examiner
ROY, BAISAKHI
Art Unit
3797
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Hukui Biotechnology Co. Ltd.
OA Round
2 (Final)
78%
Grant Probability
Favorable
3-4
OA Rounds
1y 10m
Est. Remaining
97%
With Interview

Examiner Intelligence

Grants 78% — above average
78%
Career Allowance Rate
541 granted / 694 resolved
+8.0% vs TC avg
Strong +19% interview lift
Without
With
+18.6%
Interview Lift
resolved cases with interview
Typical timeline
3y 9m
Avg Prosecution
19 currently pending
Career history
720
Total Applications
across all art units

Statute-Specific Performance

§101
7.6%
-32.4% vs TC avg
§103
53.7%
+13.7% vs TC avg
§102
12.0%
-28.0% vs TC avg
§112
15.9%
-24.1% vs TC avg
Black line = Tech Center average estimate • Based on career data from 694 resolved cases

Office Action

§103
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Response to Arguments Applicant's arguments filed 8/21/2026 have been fully considered but they are not persuasive. Applicant argues that the Axelrod reference does not teach of radial imaging device because the multimodal endoscopic system only captures images in the axial direction (Remarks). The disclosure in paragraphs [0071 and 0072] of Axelrod et al. mention that the endoscope can combine multiple imaging modes…referring to Fig. 1 of Axelrod et al., the multiple imaging modes possessed by the endoscope in Axelrod et al. are all for capturing images in the axial direction…(Remarks, page 4). Looking at figure 1 of Axelrod et al., (as set forth by the Applicant Remarks), it is not clear where it is indicated that the image capture is only in the axial direction. Claim 1 recites the composite endoscope device to include a radial imaging device such as (OCT, ultrasound, or NBI from claim 2). The portion of the claim reciting “for capturing an image in a first radial direction” is functional language and does not add any further structure to the device claim. It is well known that MOEMS (Micro-Opto-Electro-Mechanical Systems , [0052, Axelrod]) integrated with endoscopic OCT can result in radial imaging and scanning. Therefore, under broadest reasonable interpretation, the Axelrod reference teaches of a MOEMS scanner head unit with endoscopic OCT that is capable of capturing an image in a radial direction. Therefore, this meets the claim requirement for an imaging device such as OCT as part of a multi-modal or composite endoscopic imaging device with MOEMS scanning head that is capable of radial imaging. The claim does not require for any further specifical structural requirement for the radial imaging device or the combined functioning of the axial/radial imaging devices to obtain a desired image. “In summary, Axelrod et al. does not disclose or teach the technical features of "a first radial imaging device" recited in claim 1 of the present application. Thus, a person having ordinary skill in the art to which the present invention pertains would not be motivated to arrive at the claimed composite endoscopic imaging device based on the disclosure of Axelrod et al., nor achieve the effect of enabling operators to simultaneously obtain different types and/or direction of images, thereby improving the efficiency of examination, diagnosis, or sampling of internal organs and tissues of the human body” (Page 5 Remarks). It is not clear where the claim language or the specification recite or provide support for “simultaneously obtaining different types and/or directions of images…” “During use, an endoscope system may be guided to a lesion site by using the axial imaging device 11. Then, the composite endoscopic imaging device 10 is rotated along a direction as indicated by the arrow on the right of FIG. 1 to allow the first radial imaging device 13 to obtain a full-range image” [0036]. The above disclosure from the specification provide further explanation on the combined scanning mechanism with respect to the axial imaging providing the initial guidance to the lesion and then rotation along a direction allowing the radial imaging device to obtain full-range image. It is suggested that the claim language recite further structure with respect to exact positioning of the radial imaging device relative to the axial imaging device and the combined functioning of the two imaging devices to obtain a full-range image (as presented above from the application specification). In view of the broad nature of the claims with respect to structure/positioning/combined functioning of the two imaging devices within the composite endoscopic imaging device, the 103 Rejection is maintained and repeated below. In view of lack of additional Remarks with respect to claims 2-10, the rejection is maintained Claim Rejections - 35 USC § 103 The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. Claim(s) 1-10 is/are rejected under 35 U.S.C. 103 as being unpatentable over Axelrod et al. (2011/0282192). With respect to claim 1, Axelrod et al. teach of a composite endoscopic imaging device or a fiber-optic multimodal OCT/photoacoustic endoscope with beam scanning by a 2D MEMS scanner present in the endoscopic head where the photoacoustic, OCT, and multi-spectral light sources are coupled to the endoscopic head (fig. 1, [0071]). Axelrod et al. teach of an axial imaging device for capturing an image in an axial direction of the composite endoscopic imaging device [0102, 0104]. Axelrod et al. teach of the composite endoscopic imaging device to include lenses (fig. 2, 3), a photosensitive element or photodetector disposed on an imaging path of the lens [0088, 0090] or CCD/CMOS [0051]. Axelrod et al. teach of the endoscope head module (MOEMS) to be equipped with a MEMS scanner and control electronics which are aligned by location in tight tolerance polyimide tubing (fig. 3, 4, 0066, 0075, 0082, 0084) and therefore under broadest reasonable interpretation, the composite endoscopic imaging device obviously includes a flexible printed circuit board as a MEMS scanner unit in an endoscope is very commonly integrated onto a flexible printed circuit board without requiring bulky space required for conventional wires. Axelrod et al. teach of a first radial imaging device or OCT device disposed behind the photoacoustic imaging device for capturing an image in a first radial direction of the composite endoscopic imaging device [0071, 0072, fig. 1]. With respect to claim 2, Axelrod et al. teach of the use of the first radial imaging device being an OCT device and the second radial imaging device to be photoacoustic imaging device or a combination of the photoacoustic, OCT, and multi-spectral imaging modalities [0064, 0081] with combination of OCT/PA imaging and switching between the different modalities [0081, 0083, claim 1]. With respect to claims 3 and 4, Axelrod et al. teach of the axial imaging device to comprise a reflection device disposed on the imaging path of the lens where the reflection device is a mirror [0075, 0077, 0080, fig. 2]. Axelrod et al. further teach of the upper surface of the photosensitive element or photodetector to be parallel to the axial direction and the lens forms an image on the photodetector via the mirror [0077, 0088]. With respect to claim 5, Axelrod et al. teach of the reflection device to be a double-sided reflection device or a beam-splitter [0090] and the first radial imaging device is an OCT device acquiring tomography image via the beam-splitter [0101]. With respect to claim 6, Axelrod et al. teach of the upper surface of the photodetector is perpendicular to the axial direction (fig. 2, 4) with the lens directly forming an image on the photodetector [0088] or the CCD/CMOS camera [0051] with the flexible printed circuit board or the MEMS scanner which are aligned by location in tight tolerance polyimide tubing allowing bending near the photodetector element (fig. 3, 0066, 0075). With respect to claim 7, Axelrod et al. teach of a second radial imaging device such as the photoacoustic imaging device disposed below the flexible printed circuit or the polyimide tubing as part of the endoscopic head for capturing an image in a second radial direction of the composite endoscopic imaging device [fig. 4, 0089, 0105]. With respect to claims 8-10, Axelrod et al. teach of the use of the first radial imaging device being an OCT device and the second radial imaging device to be photoacoustic imaging device or a combination of the photoacoustic, OCT, and multi-spectral imaging modalities [0064, 0081] with combination of OCT/PA imaging and switching between the different modalities [0081, 0083, claim 1]. Axelrod et al. teach of using the optical switch to switch from one imaging modality to another without removing the endoscope inserted into the body [0061] and incorporated in the single endoscopic head (fig. 1, 0072, 0081) and therefore it would be obvious that the first/second radial imaging device modalities are located in opposite directions to ensure switching between the modalities without removing the endoscope from the body. Axelrod et al. do not teach of all the claimed elements in a single embodiment. It would have therefore been obvious to one of ordinary skill in the art to combine elements from the different embodiments to integrate simultaneous use of multiple imaging modalities and switch between the modalities without removing the inserted endoscope from the body [0030]. Conclusion THIS ACTION IS MADE FINAL. Applicant is reminded of the extension of time policy as set forth in 37 CFR 1.136(a). A shortened statutory period for reply to this final action is set to expire THREE MONTHS from the mailing date of this action. In the event a first reply is filed within TWO MONTHS of the mailing date of this final action and the advisory action is not mailed until after the end of the THREE-MONTH shortened statutory period, then the shortened statutory period will expire on the date the advisory action is mailed, and any nonprovisional extension fee (37 CFR 1.17(a)) pursuant to 37 CFR 1.136(a) will be calculated from the mailing date of the advisory action. In no event, however, will the statutory period for reply expire later than SIX MONTHS from the mailing date of this final action. Any inquiry concerning this communication or earlier communications from the examiner should be directed to BAISAKHI ROY whose telephone number is (571)272-7139. The examiner can normally be reached Monday-Friday 7-3 EST. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Christopher Koharski can be reached at 571-272-7230. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. BR /BAISAKHI ROY/Primary Examiner, Art Unit 3797
Read full office action

Prosecution Timeline

Dec 12, 2024
Application Filed
Jun 02, 2026
Non-Final Rejection mailed — §103
Aug 21, 2026
Response Filed
Oct 02, 2026
Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12773104
ENDOSCOPE WITH OPTICAL IMAGING SYSTEM
2y 3m to grant Granted Oct 27, 2026
Patent 12758101
DETERMINING ANGULAR ORIENTATION FOR IMAGING
2y 5m to grant Granted Oct 13, 2026
Patent 12751683
SYSTEMS AND METHODS FOR IMAGE ACQUISITION
3y 4m to grant Granted Oct 06, 2026
Patent 12751630
MULTISPECTRAL PHOTOACOUSTIC DEVICES
3y 1m to grant Granted Oct 06, 2026
Patent 12745938
FETAL MAGNETOCARDIOGRAPHY SYSTEMS AND METHODS
2y 6m to grant Granted Sep 29, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
78%
Grant Probability
97%
With Interview (+18.6%)
3y 9m (~1y 10m remaining)
Median Time to Grant
Moderate
PTA Risk
Based on 694 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month