Prosecution Insights
Last updated: November 24, 2026
Application No. 19/081,296

Aerodynamically Streamlined Enclosure for Input Devices of a Medication Preparation System

Final Rejection §103
Filed
Mar 17, 2025
Priority
Sep 08, 2014 — provisional 62/047,325 +7 more
Examiner
MESSMORE, JONATHAN R
Art Unit
2482
Tech Center
2400 — Computer Networks
Assignee
Becton, Dickinson and Company
OA Round
2 (Final)
77%
Grant Probability
Favorable
3-4
OA Rounds
1y 0m
Est. Remaining
87%
With Interview

Examiner Intelligence

Grants 77% — above average
77%
Career Allowance Rate
408 granted / 527 resolved
+19.4% vs TC avg
Moderate +10% lift
Without
With
+9.5%
Interview Lift
resolved cases with interview
Typical timeline
2y 9m
Avg Prosecution
23 currently pending
Career history
567
Total Applications
across all art units

Statute-Specific Performance

§101
4.9%
-35.1% vs TC avg
§103
51.6%
+11.6% vs TC avg
§102
23.5%
-16.5% vs TC avg
§112
12.8%
-27.2% vs TC avg
Black line = Tech Center average estimate • Based on career data from 527 resolved cases

Office Action

§103
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Information Disclosure Statement The information disclosure statement(s) (IDS) was/were submitted on 5 August 2026. The submission is in compliance with the provisions of 37 CFR 1.97. Accordingly, the information disclosure statement(s) is/are being considered by the examiner. Response to Arguments Applicant request all Non-Statutory Double Patenting rejections be held in abeyance until allowable subject material is determined. Applicant’s arguments, see Response to Office Action mailed 8 June 2026, filed 7 October 2026, with respect to Claim Rejections under 35 USC §112 have been fully considered and are persuasive. The Claim Rejections under 35 USC §112 of Claims 2 and 14 has been withdrawn. Applicant’s arguments, see Response to Office Action mailed 8 June 2026, filed 7 October 2026, with respect to the rejection(s) of claim(s) 1-17 and 19-22 under 35 USC §103 have been fully considered and are persuasive. Therefore, the rejection has been withdrawn. However, upon further consideration, a new ground(s) of rejection is made in view of Moore et al. (US 2012/0127540 A1). Claim Rejections - 35 USC § 103 The text of those sections of Title 35, U.S. Code not included in this action can be found in a prior Office action. Claim(s) 1-4, 6, 10-15, 17, and 21-22 is/are rejected under 35 U.S.C. 103 as being unpatentable over Lang et al. (US 2013/0142406 A1) in view of Ito et al. (US 2015/0010758 A1), Tribble at al. (US 2010/0094653 A1), and Moore et al. (US 2012/0127540 A1). Regarding Claims 1, 7, and 13, Lang discloses a system for preparing a pharmaceutical compound, comprising: a base comprising a scale having a platen configured for placement of an object thereon [Lang: FIG. 2], the platen comprising: one or more recessed grooves [Lang: ¶ [0028]: The tray 48 may be self-aligning in some embodiments, such as by fitting into a similarly-sized recess in the surface of the stage 44, by having alignment fittings in the tray 48]; and a transparent and/or translucent material configured to permit passage of light therethrough [Lang: ¶ [0028]: As shown in FIG. 2, a user-removable tray 48, which may be washable, sterilizable, and/or disposable, and which is substantially transparent to such portion of the electromagnetic spectrum]; a supporting arm comprising a first end coupled to a portion of the base and a second end extending to a position above the platen of the scale [Lang: FIG. 2]; an enclosure housing comprising a first enclosure housing end and a second enclosure housing end, the first enclosure housing end attached to and extending from the second end of the supporting arm, and the second end of the enclosure housing extending over the platen of the scale [Lang: FIG. 2] and comprising a portion that is concave along an axis defined by the first enclosure housing end and the second enclosure housing end [Lang: FIG. 2], wherein a field of view of the image capture device includes the platen [Lang: FIG. 2; and ¶ [0028]], wherein the enclosure housing has a curved profile to minimize flow disturbance [Lang: FIG. 2]; an image capture device received within the enclosure housing and operatively connected to the scale [Lang: ¶ [0030]: the light source 62 may include a discretely identifiable illumination source power control module 68 that emits radiation 70, such as infrared light, that passes through a stage 72 and is blocked in part by subject units 74 (e.g., pills). A portion of the unblocked radiation 76 impinges on a camera 78, functioning as an image acquisition component]; an infrared camera received within the enclosure housing [Lang: ¶ [0030]]; and a user interface arranged on the base, the user interface operatively connected to the scale [Lang: ¶ [0028]: an operator interface cluster 34 integrated into a base 36 on a sloped face 38 thereof]. Lang may not explicitly disclose configured to detect a change in mass when an object is placed thereon; one or more recessed grooves [as shown in the instant application FIG. 4]; and the system is positioned within a flow hood. However, Ito discloses one or more recess grooves [Ito: FIG. 7]. Ito may not explicitly disclose configured to detect a change in mass when an object is placed thereon; and the system is positioned within a flow hood. However, Tribble may disclose the system is positioned within a flow hood [Tribble: ¶ [0141] The present system combines a macro-level workflow manager that tracks the status of dose production in the pharmacy IV room from the receipt of the dose order, through preparation at a workstation that can include a laminar flow hood]. Tribble may not explicitly disclose configured to detect a change in mass when an object is placed thereon. However, Moore discloses configured to detect a change in mass when an object is placed thereon [Moore: ¶ [0027] Scales 26 and 32 are communicatively linked to the system 42 by one or more wired or wireless links 60, 62 for communicating signals 64, 66 representative of the addition of envelope or document to the respective scale. System 42 includes a weight change detector 68 which receives the signals 64, 66 and outputs a signal if a weight above a threshold is detected. The current weight of each stack 24, 30 may also be stored in memory 52. In the case of signals from the first scale 26, the output of the weight change detector 68 may be received by a user signaling controller 70 which actuates a switch 72 for lamp 28. In the case of signals indicating a threshold weight change from the second scale 32, the weight change detector may signal to a job/batch counter 76 and/or a camera controller 78]. It would have been obvious to one having ordinary skill in the art before the effective filing date to combine the flow hood of Tribble with the system of Lang in order to provide safer working environment for users, as well as the recessed grooves of Ito in order to provide mitigation for objects rolling around and the weight threshold detection process of Moore in order to reduce interference. Regarding Claims 2 and 14, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Furthermore, Lang in view of Ito, Tribble, and Moore discloses wherein the second end of the enclosure housing has a curved profile to minimize flow disturbance within a flow hood [Lang: FIG. 2]. Regarding Claims 3 and 15, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Furthermore, Lang in view of Ito, Tribble, and Moore discloses wherein the supporting arm is arranged such that a center of a field of view of the image capture device coincides with a center of the platen [Lang: FIG. 2]. Regarding Claims 4, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Furthermore, Lang in view of Ito, Tribble, and Moore discloses further comprising a printer [Lang: ¶ [0051]: printer]. Regarding Claims 6 and 17, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Furthermore, Lang in view of Ito, Tribble, and Moore discloses further comprising a barcode scanner received within the enclosure housing and operatively connected to the scale [Lang: ¶ [0034]: barcode scanner]. Regarding Claims 10 and 21, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Furthermore, Lang in view of Ito, Tribble, and Moore discloses wherein the enclosure housing is configured such that, when the system is placed in a laminar flow hood, a consistent pressure is applied to the scale [Tribble: ¶ [0141]; wherein it is understood normal air pressure is considered consistent]. Regarding Claims 11 and 22, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Furthermore, Lang in view of Ito, Tribble, and Moore discloses wherein the enclosure housing is configured such that, when the system is placed in a laminar flow hood, drag is minimized [Lang: FIG. 2; Tribble: ¶ [0141]; wherein “minimized” appears to be a broad term which may be interpreted as reducing drag in any amount]. Regarding Claim 12, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claim 1, and is analyzed as previously discussed with respect to that claim. Furthermore, Lang in view of Ito, Tribble, and Moore discloses wherein the second enclosure housing end comprises a portion that is concave along an axis defined by the first enclosure housing end and the second enclosure housing end [Lang: FIG. 2]. Claim(s) 5 and 16 is/are rejected under 35 U.S.C. 103 as being unpatentable over Lang in view of Ito, Tribble, and Moore as applied to claims 1 and 13 above, and further in view of Hoare et al. (US 2015/0257574 A1). Regarding Claims 5 and 16, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Lang in view of Ito, Tribble, and Moore may not explicitly disclose further comprising a printer integral with the base. However, Hoare discloses further comprising a printer integral with the base [Hoare: ¶ [0112]: Electronic scales associated with the appliance 250 may have an integral label printer for creating a barcode such as a 2D barcode 255]. It would have been obvious to one having ordinary skill in the art before the effective filing date to combine the integral printer of Hoare with the system of Lang in view of Ito, Tribble, and Moore in order to provide compact tools with integrated peripheries. Claim(s) 8 and 19 is/are rejected under 35 U.S.C. 103 as being unpatentable over Lang in view of Ito, Tribble, and Moore as applied to claims 1 and 13 above, and further in view of Luchinger (US 2011/0286886 A1). Regarding Claims 8 and 19, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Lang in view of Ito, Tribble, and Moore may not explicitly disclose wherein the enclosure housing is configured such that the scale exhibits a gravimetric accuracy of +/-0.05 g. However, Luchinger discloses wherein the enclosure housing is configured such that the scale exhibits a gravimetric accuracy of +/-0.05 g [Luchinger: ¶ [0011]: The term "high-resolution weighing cells" refers to devices which allow the mass of a weighing object to be measured with an accuracy as fine as a microgram]. It would have been obvious to one having ordinary skill in the art before the effective filing date to combine the high accuracy scale of Luchinger with the system of Lang in view of Ito, Tribble, and Moore in order to provide improved accuracy. Claim(s) 9 and 20 is/are rejected under 35 U.S.C. 103 as being unpatentable over Lang in view of Ito, Tribble, and Moore as applied to claims 1 and 13 above, and further in view of Dartus [US 5938074 A]. Regarding Claims 9 and 20, Lang in view of Ito, Tribble, and Moore discloses all the limitations of Claims 1 and 13, respectively, and is analyzed as previously discussed with respect to those claims. Lang in view of Ito, Tribble, and Moore may not explicitly disclose Scales capable of weighing several grams with a weighing time of less than one second can be found on the market. However, Dartus discloses Scales capable of weighing several grams with a weighing time of less than one second can be found on the market [Dartus: Col. 2, ll. 50-55: Scales capable of weighing several grams with a weighing time of less than one second can be found on the market]. It would have been obvious to one having ordinary skill in the art before the effective filing date to combine the well-known quick-stabilization scales of Dartus with the system of Lang in view of Ito, Tribble, and Moore in order to provide improved work pace. Conclusion Applicant's amendment necessitated the new ground(s) of rejection presented in this Office action. Accordingly, THIS ACTION IS MADE FINAL. See MPEP § 706.07(a). Applicant is reminded of the extension of time policy as set forth in 37 CFR 1.136(a). A shortened statutory period for reply to this final action is set to expire THREE MONTHS from the mailing date of this action. In the event a first reply is filed within TWO MONTHS of the mailing date of this final action and the advisory action is not mailed until after the end of the THREE-MONTH shortened statutory period, then the shortened statutory period will expire on the date the advisory action is mailed, and any nonprovisional extension fee (37 CFR 1.17(a)) pursuant to 37 CFR 1.136(a) will be calculated from the mailing date of the advisory action. In no event, however, will the statutory period for reply expire later than SIX MONTHS from the mailing date of this final action. Any inquiry concerning this communication or earlier communications from the examiner should be directed to JONATHAN R MESSMORE whose telephone number is (571)272-2773. The examiner can normally be reached Monday-Friday 9-5 EST/EDT. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Chris Kelley can be reached at 571-272-7331. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /JONATHAN R MESSMORE/Primary Examiner, Art Unit 2482
Read full office action

Prosecution Timeline

Mar 17, 2025
Application Filed
Jun 08, 2026
Non-Final Rejection mailed — §103
Oct 07, 2026
Response Filed
Nov 10, 2026
Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12795163
IMAGE PROCESSING APPARATUS AND IMAGE PROCESSING METHOD
1y 8m to grant Granted Nov 10, 2026
Patent 12786391
Sub-Picture Configuration Signaling In Video Coding
5y 1m to grant Granted Nov 03, 2026
Patent 12770589
DISPLAY METHOD FOR COLLECTIVELY CHANGING DISPLAY CONTENTS OF A TRANSPORTATION VEHICLE, AND SMART DISPLAY DEVICE AND NON-TRANSITORY COMPUTER-READABLE RECORDING MEDIUM THEREOF
2y 1m to grant Granted Oct 20, 2026
Patent 12750495
IMAGE CODING METHOD AND DEVICE BASED ON GEOMETRIC PARTITIONING MODE (GPM)
1y 11m to grant Granted Sep 29, 2026
Patent 12750475
INTER PREDICTION METHOD AND APPARATUS
1y 11m to grant Granted Sep 29, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

3-4
Expected OA Rounds
77%
Grant Probability
87%
With Interview (+9.5%)
2y 9m (~1y 0m remaining)
Median Time to Grant
Moderate
PTA Risk
Based on 527 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month