Prosecution Insights
Last updated: August 06, 2026
Application No. 19/095,283

PORTABLE ENDOSCOPE WITH SIDE-MOUNTABLE DISPOSABLE PORTION

Non-Final OA §103
Filed
Mar 31, 2025
Priority
Dec 05, 2019 — CIP of 11/071,442 +1 more
Examiner
SURGAN, ALEXANDRA L
Art Unit
Tech Center
Assignee
UroViu Corp.
OA Round
1 (Non-Final)
48%
Grant Probability
Moderate
1-2
OA Rounds
2y 7m
Est. Remaining
76%
With Interview

Examiner Intelligence

Grants 48% of resolved cases
48%
Career Allowance Rate
244 granted / 512 resolved
-12.3% vs TC avg
Strong +28% interview lift
Without
With
+28.0%
Interview Lift
resolved cases with interview
Typical timeline
3y 12m
Avg Prosecution
33 currently pending
Career history
543
Total Applications
across all art units

Statute-Specific Performance

§101
1.4%
-38.6% vs TC avg
§103
62.0%
+22.0% vs TC avg
§102
17.1%
-22.9% vs TC avg
§112
18.4%
-21.6% vs TC avg
Black line = Tech Center average estimate • Based on career data from 512 resolved cases

Office Action

§103
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Status of Claims Claims 1-14 are pending and currently under consideration for patentability under 37 CFR 1.104. Drawings The drawings are objected to under 37 CFR 1.83(a). The drawings must show every feature of the invention specified in the claims. Therefore, the at least one additional port comprises both a proximal port at a proximal portion of the insert housing and a distal port at a distal portion of the insert housing (claim 14) must be shown or the feature(s) canceled from the claim(s). No new matter should be entered. Corrected drawing sheets in compliance with 37 CFR 1.121(d) are required in reply to the Office action to avoid abandonment of the application. Any amended replacement drawing sheet should include all of the figures appearing on the immediate prior version of the sheet, even if only one figure is being amended. The figure or figure number of an amended drawing should not be labeled as “amended.” If a drawing figure is to be canceled, the appropriate figure must be removed from the replacement sheet, and where necessary, the remaining figures must be renumbered and appropriate changes made to the brief description of the several views of the drawings for consistency. Additional replacement sheets may be necessary to show the renumbering of the remaining figures. Each drawing sheet submitted after the filing date of an application must be labeled in the top margin as either “Replacement Sheet” or “New Sheet” pursuant to 37 CFR 1.121(d). If the changes are not accepted by the examiner, the applicant will be notified and informed of any required corrective action in the next Office action. The objection to the drawings will not be held in abeyance. Claim Rejections - 35 USC § 103 The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. Claim(s) 1-10 is/are rejected under 35 U.S.C. 103 as being unpatentable over Ouyang et al. (U.S. 2018/0132700) in view of Trusty et al. (U.S. 2011/0152612). With respect to claim 1 Ouyang et al. teaches a single-use, disposable portion of an endoscope comprising: an insert housing (130) elongated along a longitudinal axis and having an electrical connector (310); a cannula (120) extending distally from said insert housing along the longitudinal axis; wherein said insert housing comprises a snap-in portion that is elongated along the longitudinal axis and is shaped and configured for insertion, in a snap-in motion in a snap-in direction transverse to the longitudinal axis, into a correspondingly shaped slot (FIG. 3A,B); wherein the cannula is mounted to the insert housing for rotation about the longitudinal axis relative to the insert housing (FIG. 3C); a proximal port (132) at a proximal end of the insert housing; a working lumen (420) extending along said axis from the proximal port to a distal portion of the cannula; an imaging and illumination module mounted at the distal portion of the cannula and operatively coupled to the electrical connector (FIG. 4); and a cable (410) electrically coupling the imaging and illumination module with the electrical connector, wherein the cable has a distal portion inside said cannula (FIG. 4 for example) and a proximal portion that is operatively coupled with the electrical connector and is sufficiently long and flexible to enable rotation of at least 180 degrees of the cannula relative to the insert housing about said longitudinal axis (FIG. 3C). However, Ouyang et al. does not teach positioning aids configured to facilitate the snap-in insertion and to releasably secure the insert housing in place. With respect to claim 1, Trusty et al. teaches positioning aids configured to facilitate the snap-in insertion and to releasably secure the insert housing in place (para [0022]). Therefore, it would have been prima facie obvious to one of ordinary skill in the art at the time of the effective filing date to modify Ouyang et al. to include positioning aids in the manner taught by Trusty et al. in order to retain the cannula in the desired position (para [0022] of Trusty et al.). With respect to claim 2, Trusty et al. teaches the positioning aids include spring-loaded projections (para [0022]) configured to move along directions that are transverse both to the longitudinal axis and to the snap-in direction. With respect to claim 3, Trusty et al. teaches the spring-loaded projections extend down from a bottom side of the insert housing and are configured to move in directions normal to the bottom side of the insert housing (para [0022]). With respect to claim 4, Trusty et al. teaches the spring-loaded projections comprise spring loaded balls (para [0022]). With respect to claim 5, Trusty et al. teaches the positioning aids further include one or more posts projecting in the snap-in direction (FIG. 7). With respect to claim 6, Ouyang et al. teaches the electrical connector faces in a proximal direction and the snap-in motion further includes a component in a direction along said longitudinal axis (FIG. 3A,B). With respect to claim 7, a rearrangement of parts is considered to be within the level of one of ordinary skill in the art In re Japikse, 181 F.2d 1019, 86 USPQ 70 (CCPA 1950) With respect to claim 8 Ouyang et al. teaches the cannula further includes a cable lumen (430) extending from the imaging and illumination module to the electrical connector and housing the cables (para [0043]). With respect to claim 9, Ouyang et al. teaches in which the electrical connector is above the snap-in portion of the insert housing (when upside down, FIG. 3A,B). With respect to claim 10, Ouyang et al. teaches the electrical connector is below the snap-in portion of the insert housing (FIG. 3A,B). Claim(s) 11-14 is/are rejected under 35 U.S.C. 103 as being unpatentable over Ouyang et al. (U.S. 2018/0132700) in view of Trusty et al. (U.S. 2011/0152612) as applied to claim 1 above and further in view of Truckai et al. (U.S. 2018/0184892). Ouyang et al. in view of Trusty et al. teaches a single-use, disposable portion of an endoscope as set forth above. However, Ouyang et al. in view of Trusty et al. does not teach the insert housing further includes at least one additional port communicating with the working lumen. With respect to claim 11, Truckai et al. teaches the insert housing further includes at least one additional port (515), communicating with the working lumen (FIG. 9). With respect to claim 12, Truckai et al. teaches the at least one additional port comprises a proximal port at a proximal portion of the insert housing (FIG. 9). With respect to claim 13, Ouyang et al. as modified by Truckai et al. teaches the at least one additional port comprises a distal port at a distal portion of the insert housing (FIG. 3A,B of Ouyang et al., FIG. 9 of Truckai et al.). With respect to claim 14, Ouyang et al. as modified by Truckai et al. teaches the at least one additional port comprises both a proximal port at a proximal portion of the insert housing and a distal port at a distal portion of the insert housing (FIG. 3A,B of Ouyang et al., FIG. 9 of Truckai et al.). Therefore, it would have been prima facie obvious to one of ordinary skill in the art at the time of the effective filing date to modify Ouyang et al. to include an additional port in the manner taught by Truckai et al. in order to allow for the insertion of tools (para [0048] of Truckai et al.). Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to Alexandra Newton Surgan whose telephone number is (571)270-1618. The examiner can normally be reached Monday-Friday 8am-4pm EST. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Michael Carey can be reached at (571) 270-7235. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /ALEXANDRA L NEWTON/ Primary Examiner, Art Unit 3799
Read full office action

Prosecution Timeline

Mar 31, 2025
Application Filed
Jul 30, 2026
Non-Final Rejection mailed — §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12690752
ERGONOMIC CONTROLS FOR ENDOSCOPE
3y 3m to grant Granted Jul 28, 2026
Patent 12685848
CHEST TUBE INSERTION DEVICE USING ENDOSCOPIC GUIDE
4y 3m to grant Granted Jul 21, 2026
Patent 12635854
MOTOR-DRIVEN ENDOSCOPE
3y 2m to grant Granted May 26, 2026
Patent 12635863
Endoscopy Device and Endoscopy System with Annular View
3y 5m to grant Granted May 26, 2026
Patent 12629284
Ear Cleaning Arrangement
1y 11m to grant Granted May 19, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
48%
Grant Probability
76%
With Interview (+28.0%)
3y 12m (~2y 7m remaining)
Median Time to Grant
Low
PTA Risk
Based on 512 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month