Prosecution Insights
Last updated: November 15, 2026
Application No. 19/111,866

IMPROVEMENTS IN OR RELATING TO A MEDICAL SIMULATION SYSTEM

Non-Final OA §102§103§112
Filed
Mar 14, 2025
Priority
Sep 16, 2022 — GB 2213614.7 +3 more
Examiner
BODENDORF, ANDREW
Art Unit
3715
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Limbs & Things Limited
OA Round
1 (Non-Final)
30%
Grant Probability
At Risk
1-2
OA Rounds
68%
With Interview

Examiner Intelligence

Grants only 30% of cases
30%
Career Allowance Rate
35 granted / 116 resolved
-39.8% vs TC avg
Strong +37% interview lift
Without
With
+37.3%
Interview Lift
resolved cases with interview
Typical timeline
Avg Prosecution
26 currently pending
Career history
146
Total Applications
across all art units

Office Action

§102 §103 §112
Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Status of Claims This action is in response to the preliminary amendment filed on March 14, 2025. Claims 1, 2, 5-9, 11, and 13-24 are pending, of which claims 1, 5-8, 11, 13, 16-19, and 22-24 have been amended and claims 3, 4, 10, 12, and 25 have been canceled. Information Disclosure Statement The information disclosure statement (IDS) submitted on April 9, 2025 is in compliance with the provisions of 37 CFR § 1.97. Accordingly, the IDS has been considered by the examiner. Drawings The drawings are objected to under 37 CFR 1.83(a). The drawings must show every feature of the invention specified in the claims. Therefore, the control unit must be shown or the feature canceled from the claims. No new matter should be entered. The drawings are objected to informalities. Figs. 3, 4A, 5A, 6, and 7 include grayscale and blurred lines that are difficult to read and/or reproduce. Legibility includes ability to be photocopied and scanned so that suitable reprints can be made and paper can be electronically reproduced by use of digital imaging and optical character recognition. This requires a high contrast, with black lines and a white background. Gray lines and/or a gray background sharply reduce photo reproduction quality. Appropriate correction is required. In addition, Fig. 7 lacks lead lines for the reference characters. The reference characters should be underlined to indicate the correspond to the blocks in which they are located. Fig. 7 also appears to include unlabeled artifacts near the blocks surrounding elements 650/608 and 690/692. Also these blocks also are not labeled or identified by reference characters. Appropriate correction is required. Corrected drawing sheets in compliance with 37 CFR § 1.121(d) are required in reply to the Office action to avoid abandonment of the application. Any amended replacement drawing sheet should include all of the figures appearing on the immediate prior version of the sheet, even if only one figure is being amended. The figure or figure number of an amended drawing should not be labeled as “amended.” If a drawing figure is to be canceled, the appropriate figure must be removed from the replacement sheet, and where necessary, the remaining figures must be renumbered and appropriate changes made to the brief description of the several views of the drawings for consistency. Additional replacement sheets may be necessary to show the renumbering of the remaining figures. Each drawing sheet submitted after the filing date of an application must be labeled in the top margin as either “Replacement Sheet” or “New Sheet” pursuant to 37 § CFR 1.121(d). If the changes are not accepted by the examiner, the applicant will be notified and informed of any required corrective action in the next Office action. The objection to the drawings will not be held in abeyance. Specification The disclosure is objected to because of the following informalities: P. 7, l.25 includes the language “to replicate thrills generate by heart” which should read -- to replicate thrills generated by heart --. Appropriate correction is required. P. 8, l.18 includes the language “to replicate a thrill generate by one of the four heart valves” which should read -- to replicate a thrill generated by one of the four heart valves --. Appropriate correction is required. P. 10, l.28 includes the language “the base may positioned” which should read -- the base may be positioned --. Appropriate correction is required. P. 12, l.5 includes the language “may results in” which should read -- may result in --. Appropriate correction is required. P. 12, l.6 includes the language “increasing the number steps” which should read -- increasing the number of steps --. Appropriate correction is required. P. 12, l.23 includes the language “that is generate by a given plate” which should read -- that is generated by a given plate --. Appropriate correction is required. P. 17, l.17 “However, is Figure 5B, plate 525 has been omitted.” which should read -- However, in Figure 5B, plate 525 has been omitted. --. Appropriate correction is required. Claim Rejections - 35 USC § 112 The following is a quotation of the first paragraph of 35 U.S.C. 112(a): (a) IN GENERAL.—The specification shall contain a written description of the invention, and of the manner and process of making and using it, in such full, clear, concise, and exact terms as to enable any person skilled in the art to which it pertains, or with which it is most nearly connected, to make and use the same, and shall set forth the best mode contemplated by the inventor or joint inventor of carrying out the invention. Claims 1, 2, 5-9, 11, and 13-24 are rejected under 35 U.S.C. 112(a), as failing to comply with the written description requirement. The claims contain subject matter which was not described in the specification in such a way as to reasonably convey to one skilled in the relevant art that the inventor or a joint inventor, at the time the application was filed, had possession of the claimed invention. The claims recite the following computer/processor-based function limitations: ` 1) wherein the module is configured to output content from the memory via the transmitter when the RFID reader detects the RFID tag, and wherein the medical simulation system further comprises (claim 1); 2) a processor configured to synchronize the output to the movement of the mechanically moveable element. a receiving unit that receives an input of the pieces of timing information indicated by the indicating regions (claim 1) 3) a processor configured to synchronize vibration of the thrill simulation actuator to the movement of a mechanically moveable element (claim 11) 4) comprising a processor configured to synchronize the output to the rotation of the plate (claim 22) According to MPEP 2161.01 I., when examining computer-implemented claims, examiners should determine whether the specification discloses the computer and the algorithm (e.g., the necessary steps, operations and/or flowcharts) that perform the claimed functions in sufficient detail such that one of ordinary skill in the art can reasonably conclude that the inventor possessed the claimed subject matter at the time of filing. An algorithm is defined, for example, as "a finite sequence of steps for solving a logical or mathematical problem or performing a task." Microsoft Computer Dictionary (5th ed., 2002). Applicant may "express that algorithm in any understandable terms including as a mathematical formula, in prose, or as a flow chart, or in any other manner that provides sufficient structure." Finisar Corp. v. DirecTV Grp., Inc., 523 F.3d 1323, 1340, 86 USPQ2d 1609, 1623 (Fed. Cir. 2008) (internal citation omitted). It is not enough that one skilled in the art could write a program to achieve the claimed function because the specification must explain how the inventor intends to achieve the claimed function to satisfy the written description requirement. See, e.g., Vasudevan Software, Inc. v. MicroStrategy, Inc., 782 F.3d 671, 681-683, 114 USPQ2d 1349, 1356, 1357 (Fed. Cir. 2015) (reversing and remanding the district court’s grant of summary judgment of invalidity for lack of adequate written description where there were genuine issues of material fact regarding "whether the specification show[ed] possession by the inventor of how accessing disparate databases is achieved"). If the specification does not provide a disclosure of the computer and algorithm in sufficient detail to demonstrate to one of ordinary skill in the art that the inventor possessed the invention a rejection under 35 U.S.C. 112(a) for lack of written description must be made. With regard to above-referenced the limitations 1) - 4), the specification appears to provide disclosure of a computer to implement the functions but lacks a complete description of the algorithms (e.g., flow chart, mathematical model, code, prose) of how to implement these functions. With regard to these limitations the specification at p. 14 describes controlling the movement of the plate driving actuator may control the rotation of the plate about its axis. The control unit may modify the speed, tempo and/or range of rotation of the plate about the axis, in use, by adjusting the speed, tempo and/or range of moment of the plate driving actuator. P. 3 describes the system may further comprise a processor configured to synchronize the output to the movement of the mechanically moveable element. For example, the output may comprise an audio file configured to replicate the sound of breathing. The mechanically moveable element may replicate the expanding and contacting of a chest. Synchronizing the output with the movable element enables the sound of the breathing to be heard at the same time as the mechanical element simulates the inhaling or exhaling of breath, for example. Other examples, including but not limited to the sound and movement of a beating heart or pulse, or a thrill, can also be envisaged. In addition, p. 20 describes the module processor 230 is also in electronic communication with a webserver and audio module (WAM) PCBA 632 located within the medical simulation unit 600. The WAM PCBA is connected to a memory 627. The memory 627 comprises all the content stored within the module memory 225. The memory 627 may also comprises additional content and or files. While the functions are described, there is no corresponding description or example of how the movements are synchronized by the controller or processor to the content. For example, there is no description, prose, drawings as to the steps or operations performed by the processor that describe how the processor 630 synchronizes the content from unit 200 stored in memory to control the and/or what constitute synchronized movements. In addition, there is no explanation of the steps or operations of how the content is determined, what is meant by synchronization, how the movement of the actuator and/or plates are coordinated with the content. Therefore, Applicant has not described in any detail what process Applicant intended to implement the functions and how the process is applied to achieve the functions recited in Applicant’s claims. Therefore, one skilled in the art is left to “guess” at what is meant by the limited description provided. The specification must explicitly disclose the algorithm for performing the claimed function, and simply reciting the claimed function in the specification will not be a sufficient disclosure for an algorithm which, by definition, must contain a sequence of steps. Blackboard, Inc. v. Desire2Learn, Inc., 574 F.3d 1371, 1383-85, 91 USPQ2d 1481, 1491-93 (Fed. Cir. 2009); Net MoneyIN, Inc. v. VeriSign, Inc., 545 F.3d 1359, 1366-67, 88 USPQ2d 1751, 1756-57 (Fed. Cir. 2008); Ex parte Rodriguez, 92 USPQ2d 1395, 1405-06 (Bd. Pat. App. & Inter. 2009). Here the specification provides no such description, therefore, the specification lacks adequate written description for the claimed functions of the computing device. As a result, claims 1, 11, 22, and 23 contain subject matter which lacks adequate written description, and for at least these reasons, claims 1, 11, 22, and 23 are found to fail the written description requirement. Claims 2, 5-9, 11, and 13-24 depend from a rejected base claim, and therefore also lack adequate written description. The following is a quotation of 35 U.S.C. § 112(b): (b) CONCLUSION.—The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the inventor or a joint inventor regards as the invention. Claims 1, 2, 5-9, 11, and 13-24 are rejected under 35 U.S.C. § 112(b), as being indefinite for failing to particularly point out and distinctly claim the subject matter which the inventor or a joint inventor, regards as the invention. In re claim 1, the claim recites the limitation “the movement of the mechanically moveable element” at lines 9-10. There is insufficient antecedent basis for these limitations in the claim. In re claim 11, the claim recites the limitation “the movement of a mechanically moveable element” at line 4. There is insufficient antecedent basis for these limitations in the claim. In re claim 20, the language “discrete” is indefinite. The term “discrete” is a subjective term that is not defined by the claim, and the specification does not provide an objective standard for ascertaining the meaning of the term “discrete” such that one of ordinary skill in the art would be reasonably apprised of the scope of the claim. Claims 2, 5-9, 11, and 13-24 depend from a rejected base claim, and therefore are rejected for at least the reasons provided for the base claim. Claim Rejections - 35 USC § 102 In the event the determination of the status of the application as subject to AIA 35 U.S.C. §§ 102 and 103 (or as subject to pre-AIA 35 U.S.C. §§ 102 and 103) is incorrect, any correction of the statutory basis for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of the appropriate paragraphs of 35 U.S.C. § 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale, or otherwise available to the public before the effective filing date of the claimed invention. (a)(2) the claimed invention was described in a patent issued under section 151, or in an application for patent published or deemed published under section 122(b), in which the patent or application, as the case may be, names another inventor and was effectively filed before the effective filing date of the claimed invention. Claim Rejections - 35 USC § 103 The following is a quotation of 35 U.S.C. § 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. The factual inquiries for establishing a background for determining obviousness under 35 U.S.C. § 103 are summarized as follows: 1. Determining the scope and contents of the prior art. 2. Ascertaining the differences between the prior art and the claims at issue. 3. Resolving the level of ordinary skill in the pertinent art. 4. Considering objective evidence present in the application indicating obviousness or nonobviousness. This application currently names joint inventors. In considering patentability of the claims the examiner presumes that the subject matter of the various claims was commonly owned as of the effective filing date of the claimed invention(s) absent any evidence to the contrary. Applicant is advised of the obligation under 37 CFR § 1.56 to point out the inventor and effective filing dates of each claim that was not commonly owned as of the effective filing date of the later invention in order for the examiner to consider the applicability of 35 U.S.C. § 102(b)(2)(C) for any potential 35 U.S.C. § 102(a)(2) prior art against the later invention. Claims 1, 2, and 5-7 are rejected under 35 U.S.C. § 102(a)(1) as being anticipated by U.S. Publication No. 2013/0196302 by Lecat (“Lecat”); or, in the alternative, are rejected under 35 U.S.C. § 103 as being unpatentable over Lecat in view of US Publication No. 2016/0055767 by Tessier et al. (“Tessier”). In re claim 1, Lecat discloses a medical simulation system [Fig. 1 shows simulation system 100 for medical training, Abstract] comprising: a medical simulation unit having a mechanically moveable element and an RFID tag [Fig. 1 shows mannequin 110 ¶¶13,14 describe a mannequin for medical training simulating heart and breath sound. The mannequin 110 may including a breathing function (mechanically moveable element) and a proximity sensor 101 may be of any type, including RFID]; and a separate module comprising an RFID reader, a transmitter and a memory for storing content, wherein the module is configured to output content from the memory via the transmitter when the RFID reader detects the RFID tag [¶¶13, 14 describe the proximity sensor 101, (which may be RFID) embedded within the mannequin 110, communicates proximity data to a controller 120. Controller 120 determines the position of the auscultation device 170 relative to mannequin 110, and thus determines which sound, or class of sounds, is appropriate for transmission. For instance, if the auscultation device 170 is found to be proximal to a heart region, then an appropriate sound may be one or more heart sounds. Accordingly, controller 120 selects an appropriate sound file from database 130 and retrieves the selected sound file. The controller 120 then communicates the sound file to a transmitter 14], and wherein the medical simulation system further comprises a processor configured to synchronize the output to the movement of the mechanically moveable element [¶¶ 13, 14, controller 120 determines the position of the auscultation device 170 relative to mannequin 110, and thus determines which sound, or class of sounds, is appropriate for transmission and the sounds that are generated could be synchronized with the EKG, breathing, pulses, and any of the other mannequin functions]. Lecat teaches a mannequin for medical training including simulating breathing functions. Such breathing functions (as shown in the art of record) may include a mechanical mechanisms to move a portion of the dummy to simulate breathing motions. As such, Lecat teaches a medical simulation unit having a mechanically moveable element. However, to the extent Lecat lacks an explicit teaching of a medical simulation unit having a mechanically moveable element, Tessier teaches a medical simulation unit having a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element [Figs. 24, 25, and 26, ¶¶90, 129, 135, 142, 144-153, describe the control panel 105 may be able to synchronize lung sounds and chest rise and fall with respiration rate. Alternatively, the control panel 105 may be able to synchronize an ECG trace, heart sounds, and pulse with heart rate. Further, the control panel 105 may be able to synchronize Korotkoff sounds with systolic and diastolic blood pressure values and applied cuff pressure. Many of the physiological functions simulated in the medical simulation system 100 are driven by a single parameter, such as heart rate or respiration rate. For example, heart rate determines how an ECG trace is displayed, when heart sounds occur, and when a pulse should happen. Similarly, respiration rate determines how a respiration trace is displayed, when lung sounds occur, and when chest motion happens. To maximize the reality of a simulation, these functions want to be synchronized so they not only occur at the correct rate, but also at the correct moment in time. This can be accomplished by sending a heartbeat trigger message and respiration trigger message to the system components. The components then create the desired simulation at the appropriate time. A motor and gear box 612R and 612L (only 612R shown in FIG. 25B) drive the mechanism 611R and 611L pushing up on the flexible ribs 607R and 607L, thus causing them to “bow” creating a breathing-like motion]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing), as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 2, Lecat discloses the module is configured to connect to a device for receiving the output [¶¶14-16 describe connecting to a database to receive/retrieve sounds]. In re claim 5, Lecat discloses a content generation unit configured to generate and/or modify the content [¶¶14-16 describe allowing modification of sounds (content)]. In re claim 6, Lecat discloses the medical simulation unit is a human mannequin or part thereof [Fig. 1 shows mannequin 110]. In re claim 7, Lecat discloses the medical simulation unit comprises a plurality of RFID tags [Claim 9 describes a second sensor (which may be RFID ¶13)]. Claims 13-18 and 20-24 are rejected under 35 U.S.C. § 103 as being unpatentable over Lecat in view of Tessier. In re claim 13, Lecat lacks, but Tessier teaches the medical simulation unit comprises a main body and a plate, wherein the plate is operably connected to a plate driving actuator configured to rotate the plate about an axis [Figs. 24-26, ¶151, among others, describe a motor and gear box 612R and 612L (only 612R shown in FIG. 25B) drive the mechanism 611R and 611L pushing up on the flexible ribs 607R and 607L, thus causing them to “bow” creating a breathing-like motion with rotation about hinges 610R/L]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including plates (ribs) and corresponding actuator, as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 14, Lecat lacks, but Tessier teaches the main body comprises a substantially planar back and wherein the axis of rotation of the plate is inclined by an angle, a, relative to the plane of the back [Fig. 24B shows body has planar back 601 and rib plates 607 hinge at angle relative to the plane]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including planar back and rotations of plates (ribs), as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 15, Lecat lacks, but Tessier teaches the axis of rotation of the plate comprises a first directional component and a second directional component, wherein the first directional component is inclined, by angle a, relative to the plane of the back and the second directional component is inclined, by angle a, relative to the plane of the back and non- parallel to the first directional component [Figs. 26A/B shows axis of rotation with multiple directional components relative to the back plane]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including multiple directional movements, as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 16, Lecat lacks, but Tessier teaches the plate driving actuator is a linear actuator having a line of actuation transverse to the axis of rotation of the plate [Fig. 25B shows actuator 611 with motor 612 is linear]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including linear actuator for moving plates (ribs), as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 17, Lecat lacks, but Tessier teaches the plate driving actuator is a linear actuator having a line of actuation substantially perpendicular to the axis of rotation of the plate [Fig. 25B shows actuator 611 with motor 612 is linear and perpendicular to the axis of hinge 610]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including actuator for rotational movement of the plates (ribs), as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 18, Lecat lacks, but Tessier teaches the plate comprises a lip portion configured to contact the main body and prevent further rotation of the plate when a predetermined maximum amount of rotation has occurred [¶150 describe the sides of the sternum plate 608 contact ridges (lip) in the structural ribs 603R and 603L that come up through openings in the flexible ribs 607R and 608R]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including plates and corresponding actuators with lip/ridge, as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. in re claim 20, Lecat lacks, but Tessier teaches a switch configured to allow movement of the plate driving actuator only when the skin is fitted over the main body the plate [¶¶9,77-80, 88, 89, among others, describe a controller (switch) to control power to the system that may be operated to turn on/off the manikin functions. As such it is configured to be operated by a user to only supply power when the skin is fitted over the main body]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including module to control application of power as desired, as taught by Tessier, to improve user control of the system, for example, to conserve power used by the system. In re claim 21, Lecat lacks, but Tessier teaches at least one of: a spring configured to apply pressure to a component fixed within the main body; and a damper located between the plate driving actuator and the main body [¶¶145, 150-153 describe spring mechanism 609]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including a spring mechanism, as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 22, Lecat lacks, but Tessier teaches a processor configured to synchronize the output to the rotation of the plate ¶¶90, 129, 135, 142, 144-153, describe the control panel 105 may be able to synchronize lung sounds and chest rise and fall with respiration rate. Alternatively, the control panel 105 may be able to synchronize an ECG trace, heart sounds, and pulse with heart rate. Further, the control panel 105 may be able to synchronize Korotkoff sounds with systolic and diastolic blood pressure values and applied cuff pressure. Many of the physiological functions simulated in the medical simulation system 100 are driven by a single parameter, such as heart rate or respiration rate. For example, heart rate determines how an ECG trace is displayed, when heart sounds occur, and when a pulse should happen. Similarly, respiration rate determines how a respiration trace is displayed, when lung sounds occur, and when chest motion happens. To maximize the reality of a simulation, these functions want to be synchronized so they not only occur at the correct rate, but also at the correct moment in time. This can be accomplished by sending a heartbeat trigger message and respiration trigger message to the system components. The components then create the desired simulation at the appropriate time. A motor and gear box 612R and 612L (only 612R shown in FIG. 25B) drive the mechanism 611R and 611L pushing up on the flexible ribs 607R and 607L, thus causing them to “bow” creating a breathing-like motion]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including rotational movement of the chest plates (ribs), as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 23, Lecat lacks, but Tessier teaches system according to claim 13, wherein the plate driving actuator is operably connected to a control unit configured to control the movement of the actuator ¶¶90, 129, 135, 142, 144-153, among others, describe the control panel 105 may be able to synchronize lung sounds and chest rise and fall with respiration rate. Alternatively, the control panel 105 may be able to synchronize an ECG trace, heart sounds, and pulse with heart rate. Further, the control panel 105 may be able to synchronize Korotkoff sounds with systolic and diastolic blood pressure values and applied cuff pressure. Many of the physiological functions simulated in the medical simulation system 100 are driven by a single parameter, such as heart rate or respiration rate. For example, heart rate determines how an ECG trace is displayed, when heart sounds occur, and when a pulse should happen. Similarly, respiration rate determines how a respiration trace is displayed, when lung sounds occur, and when chest motion happens. To maximize the reality of a simulation, these functions want to be synchronized so they not only occur at the correct rate, but also at the correct moment in time. This can be accomplished by sending a heartbeat trigger message and respiration trigger message to the system components. The components then create the desired simulation at the appropriate time. A motor and gear box 612R and 612L (only 612R shown in FIG. 25B) drive the mechanism 611R and 611L pushing up on the flexible ribs 607R and 607L, thus causing them to “bow” creating a breathing-like motion]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including a controller to control an actuator for the movement, as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 24, Lecat lacks, but Tessier teaches the medical simulation unit comprises a plurality of plates, and wherein each plate is connected to a corresponding plate driving actuator configured to rotate the plate about an independent axis [Figs 24-26 shows left and right plates 603R/L, 607R/L for each lung and corresponding actuators 611R/L 612R/L]. Lecat and Tessier are both considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a mechanically moveable element and synchronizing outputs to the movement of the mechanically moveable element (e.g., simulated breathing) including a plurality of plates and corresponding actuators, as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. Claims 8 and 11 are rejected under 35 U.S.C. § 103 as being unpatentable over Lecat in view of Tessier and further in view of US Publication No. 2023/0037654 by Singapogu (“Singapogu”). In re claim 8, Lecat in view of Tessier lacks, but Singapogu teaches the medical simulation unit further comprises a thrill simulation actuator configured to vibrate [¶52 describes a vibration motor may be embedded to render feedback for palpation. By controlling the power and frequency of the vibration, the characteristic “thrill” haptic sensation of blood flow in an AVF is simulated]. Lecat, Tessier, Singapogu are considered to be analogous to the claimed invention because they are in the same field of medical training simulators. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat and include a thrill simulation actuator configured to vibrate, as taught by Singapogu, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient. In re claim 11, Lecat in view of Tessier and Singapogu and Singapogu teach a processor configured to synchronize vibration. Tessier teaches a processor configured to synchronize bodily functions. It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the training manikin as taught by Singapogu to a thrill simulation actuator configured to vibrate and to synchronize it movement with other bodily functions (such as breathing), as taught by Tessier, in order to provide a better training experience, for example, by providing a more realistic simulation and/or anatomically correct simulated patient and to allowing training of various skills need by a medical practitioner. Claim 9 is rejected under 35 U.S.C. § 103 as being unpatentable over Lecat in view of Tessier and Singapogu and further in view of US Publication No. 2007/0117075 by Gordon et al. (“Gordon”). In re claim 9, Lecat in view of Tessier and Singapogu teach simulating a thrill with vibrations. The combination does not explicitly teach the thrill simulation actuator is a linear actuator. However, Gordon describes a manikin with linear actuators to simulate vibrations associated with physiological signals such as pulse Fig. 10. Pulsation generators are disposed inside the hollow body 14 of the manikin and reach the outer flexible layer representing the skin of the manikin. They are attached to the hard wall 12 of the body 14. The pulsation generators are configured to simulate movements mimicking cardiovascular pulsations and respiratory movements of the human body including ausculatory areas [¶49 62 describe the linear actuating members 106R and 106L]. Lecat, Tessier, Singapogu, and Gordon are considered to be analogous to the claimed invention because they are in the same field of medical training simulators. It would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the training manikin to substitute on type of actuator (vibration a thrill simulation actuator) as taught by Singapogu with another type of actuator (linear) as taught by Gordon, in order to achieve the predictable result of providing a signal for medical training that simulates a physiological condition. Claim 19 is rejected under 35 U.S.C. § 103 as being unpatentable over Lecat in view of Tessier and further in view of EP Publication No. EP0263156 by Dorleans (“Dorleans”). In re claim 19, Lecat in view of Tessier teach simulated skin to enclose the main body and the plate ¶¶31,81,151. Lecat in view of Tessier lacks, but Dorleans teaches a skin for a medical simulation dummy wherein a discrete area of the skin comprises reinforcement [¶7]. Lecat, Tessier, and Dorleans are considered to be analogous to the claimed invention because they are in the same field of medical training mannequins. Therefore, it would have been obvious to one of ordinary skill in the art before the effective filing date of the claimed invention to have modified the invention of Lecat in view of Tessier to include a skin for a medical simulation dummy wherein a discrete area of the skin comprises reinforcement, as taught by Dorleans, in order to provide improved performance, for example, to provide flexibility and resister tearing (See, e.g., 7, 11). Conclusion The prior art made of record and not relied upon is considered pertinent to applicant's disclosure and is listed on the attached Notice of References Cited. US 11288979 describes a housing adapted for use by a trainee to contact a surface, for example, the surface of the body of manikin, and a sensor mounted in the housing and configured to detect approach or contact of the surface by the housing. The device may include a transmitter, for example, a speaker for transmitting predetermined sounds of bodily organs, such as, heartbeats or breathing. The transmitter may be activated only upon contact or proximity of the housing with a surface as indicated by the sensor. In particular, he device may include an RFID interrogator. The devices detects an RFID tag; and identifies an audible signal associated with the RFID tag. The audible signal may be a bodily sound. US 20240221540 describes a medical mannequin. The mannequin may include a chest plate with joints for three or more rotational degrees of freedom (DOF). US 20230076333 describes a manikin with moveable chest plate including actuator to rotate a chest plate. Any inquiry concerning this communication or earlier communications from the examiner should be directed to Andrew Bodendorf whose telephone number is (571) 272-6152. The examiner can normally be reached M-F 9AM-5PM ET. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Xuan Thai can be reached on (571) 272-7147. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /ANDREW BODENDORF/Examiner, Art Unit 3715 /XUAN M THAI/Supervisory Patent Examiner, Art Unit 3715
Read full office action

Prosecution Timeline

Mar 14, 2025
Application Filed
Oct 01, 2026
Non-Final Rejection mailed — §102, §103, §112 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12792611
ARTIFICIAL INTELLIGENCE SYSTEM FOR GENERATION OF PERSONALIZED STUDY PLANS
4y 11m to grant Granted Nov 10, 2026
Patent 12779283
WORKOUT IMAGE DISPLAY METHOD AND ELECTRONIC DEVICE
3y 3m to grant Granted Nov 03, 2026
Patent 12770534
ARTICULATING PEDESTRIAN DUMMY FOR VEHICLE TESTING
2y 6m to grant Granted Oct 20, 2026
Patent 12741192
METHOD AND SYSTEM FOR IMPROVED MEASUREMENT OF THE TIME OF PASSAGE ON A TIMEKEEPING LINE
5y 1m to grant Granted Sep 22, 2026
Patent 12688789
APPARATUS FOR SIMULATING DRIVING A LAND VEHICLE
3y 6m to grant Granted Jul 21, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
30%
Grant Probability
68%
With Interview (+37.3%)
Low
PTA Risk
Based on 116 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month