Prosecution Insights
Last updated: November 25, 2026
Application No. 19/114,488

Systems and Methods for Assessing Valve-In-Valve Risks

Non-Final OA §101§102§103§112
Filed
Mar 24, 2025
Priority
Oct 07, 2022 — provisional 63/414,082 +1 more
Examiner
WANG, CLAIRE X
Art Unit
1774
Tech Center
1700 — Chemical & Materials Engineering
Assignee
Medtronic Inc.
OA Round
1 (Non-Final)
71%
Grant Probability
Favorable
1-2
OA Rounds
2y 0m
Est. Remaining
80%
With Interview

Examiner Intelligence

Grants 71% — above average
71%
Career Allowance Rate
159 granted / 223 resolved
+6.3% vs TC avg
Moderate +8% lift
Without
With
+8.2%
Interview Lift
resolved cases with interview
Typical timeline
3y 9m
Avg Prosecution
5 currently pending
Career history
236
Total Applications
across all art units

Statute-Specific Performance

§101
14.0%
-26.0% vs TC avg
§103
42.4%
+2.4% vs TC avg
§102
26.1%
-13.9% vs TC avg
§112
11.6%
-28.4% vs TC avg
Black line = Tech Center average estimate • Based on career data from 223 resolved cases

Office Action

§101 §102 §103 §112
Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Drawings The drawings are objected to because it is labeled in accordance to the WO and PCT numbers and not US application number. Corrected drawing sheets in compliance with 37 CFR 1.121(d) are required in reply to the Office action to avoid abandonment of the application. Any amended replacement drawing sheet should include all of the figures appearing on the immediate prior version of the sheet, even if only one figure is being amended. The figure or figure number of an amended drawing should not be labeled as “amended.” If a drawing figure is to be canceled, the appropriate figure must be removed from the replacement sheet, and where necessary, the remaining figures must be renumbered and appropriate changes made to the brief description of the several views of the drawings for consistency. Additional replacement sheets may be necessary to show the renumbering of the remaining figures. Each drawing sheet submitted after the filing date of an application must be labeled in the top margin as either “Replacement Sheet” or “New Sheet” pursuant to 37 CFR 1.121(d). If the changes are not accepted by the examiner, the applicant will be notified and informed of any required corrective action in the next Office action. The objection to the drawings will not be held in abeyance. Claim Rejections - 35 USC § 101 35 U.S.C. 101 reads as follows: Whoever invents or discovers any new and useful process, machine, manufacture, or composition of matter, or any new and useful improvement thereof, may obtain a patent therefor, subject to the conditions and requirements of this title. The text of those sections of Title 35, U.S. Code not included in this action can be found in a prior Office action. Claims 1-20 are rejected under 35 U.S.C. 101 because it is an abstract idea and can be performed by a technician using manual or mental processes. Claim Rejections - 35 USC § 112 The following is a quotation of 35 U.S.C. 112(b): (b) CONCLUSION.—The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the inventor or a joint inventor regards as the invention. The following is a quotation of 35 U.S.C. 112 (pre-AIA ), second paragraph: The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the applicant regards as his invention. Claims 1-20 are rejected under 35 U.S.C. 112(b) or 35 U.S.C. 112 (pre-AIA ), second paragraph, as being indefinite for failing to particularly point out and distinctly claim the subject matter which the inventor or a joint inventor (or for applications subject to pre-AIA 35 U.S.C. 112, the applicant), regards as the invention. Claim 1 recites the limitation " the first bioprosthetic valve" in line 8. There is insufficient antecedent basis for this limitation in the claim. For the purposes of furthering prosecution, Examiner interprets the limitation to be “the first bioprosthetic aortic valve”. Claim 3 recites the limitation “wherein the patient has not yet received a bioprosthetic aortic valve” in lines 1-2. This is indefinite because it is contradictory to the definition of the requirements of claim 1 of a valve-in-valve procedure since said procedure requires that there would be an existing bioprosthetic aortic valve. Claims 2 and 4-20 are rejected because they do not overcome the deficiencies of the rejected parent claim 1. Claim Rejections - 35 USC § 102 In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(2) the claimed invention was described in a patent issued under section 151, or in an application for patent published or deemed published under section 122(b), in which the patent or application, as the case may be, names another inventor and was effectively filed before the effective filing date of the claimed invention. Claims 1-5, and 7-20 are rejected under 35 U.S.C. 102(a)(2) as being anticipated by Dasi et al. (US 20240242847 A1 hereinafter Dasi). As to claim 1, Dasi teaches a method for evaluating a proposed valve-in-valve procedure for a patient in which a replacement transcatheter aortic valve will be deployed within a first bioprosthetic aortic valve (method for modeling risk of transcatheter valve deployment; Title), the method comprising: selecting predetermined benchmark measurements of a valve-in-valve combination comprising a known transcatheter aortic valve deployed within a known bioprosthetic aortic valve (pre-procedural CT images of a 74-year-old female patient who had a failed 21 mm bioprosthetic aortic valve; [0057]); receiving images of an anatomy of the patient (CT images; Fig. 8 and [0057]); obtaining anatomical measurements of the first bioprosthetic valve from the received images (Patient specific virtual models of the aortic root, bioprosthetic valve stent and leaflets were reconstructed from CT images and discretized with 3-D tetrahedral elements; Fig. 8 and [0057]); reviewing the predetermined benchmark measurements and the anatomical measurements; and evaluating risks of a valve-in-valve procedure for the patient based, at least in part, upon the review (Virtual THV implantation was simulated in both models by using finite element methods. DLC/d is a risk factor that is the ratio of the distance of the leaflet from the coronary ostium to the diameter of the coronary ostium. By assessment of the risk of coronary obstruction after THV implantation in SHV using the risk factor DLC/d, it was shown that the DLC/d was 0.32 and 0.27 for the left and right coronary arteries suggesting very high risk of coronary obstruction.; [0061]). As to claim 2, Dasi teaches the method of claim 1, wherein the first bioprosthetic aortic valve is a bioprosthetic aortic valve previously implanted within the patient (pre-procedural CT images of a 74-year-old female patient who had a failed 21 mm bioprosthetic aortic valve; [0057]), and further wherein the step of evaluating includes determining whether the replacement transcatheter aortic valve is appropriate for the patient (The patient successfully received TAVR with bilateral BASILICA based on the results from modeling, showing the capabilities of modeling in predicting success of not only THV in SHV but also the tissue modification techniques used to prevent adverse outcomes in such procedures; [0062]). As to claim 3, Dasi teaches the method of claim 1, wherein the patient has not yet received a bioprosthetic aortic valve, and further wherein the first bioprosthetic aortic valve is a bioprosthetic aortic valve under consideration for implanting into the patient (pre-procedural CT images of a 74-year-old female patient who had a failed 21 mm bioprosthetic aortic valve; [0057]). As to claim 4, Dasi teaches the method of claim 1, wherein the first bioprosthetic aortic valve is a transcatheter aortic valve (pre-procedural CT images of a 74-year-old female patient who had a failed 21 mm bioprosthetic aortic valve; [0057]). As to claim 5, Dasi teaches the method of claim 1, wherein the known transcatheter aortic valve is substantially identical to the candidate transcatheter aortic valve, and the known bioprosthetic aortic valve is substantially identical to the first bioprosthetic aortic valve (Fig. 8). As to claim 7, Dasi teaches the method of claim 1, wherein the step of evaluating includes assessing a risk of coronary artery access obstruction (Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) is a novel technique developed to mitigate the risk of coronary obstruction in patients undergoing TAVR.; [0050]). As to claim 8, Dasi teaches the method of claim 1, wherein the valve-in-valve combination defines a neo-skirt, and further wherein the predetermined benchmark measurements include a height of the neo-skirt (leaflet geometry; Fig. 9 and [0024] The tissue tube formed by the first valve's leaflets is often referred to as the neoskirt) and a diameter of the valve-in-valve combination (stent diameters; [0028]). As to claim 9, Dasi teaches the method of claim 8, wherein the neo-skirt is generated by leaflets of the known bioprosthetic aortic valve pinned between a stent frame of the bioprosthetic aortic valve and a stent frame of the known transcatheter aortic valve (Figs. 10B and 10C). As to claim 10, Dasi teaches the method of claim 9, wherein the leaflets of the known bioprosthetic aortic valve are one of fully pinned and partially pinned between the stent frames (Fig. 5). As to claim 11, Dasi teaches the method of claim 9, wherein the height of the neo-skirt is defined by a distance from an inflow end of the stent frame of the known bioprosthetic aortic valve and a pinned edge of the leaflets (leaflet geometry; Fig. 9 and [0024] The tissue tube formed by the first valve's leaflets is often referred to as the neoskirt). As to claim 12, Dasi teaches the method of claim 9, wherein the diameter is obtained at a plane (Fig. 19A) of a pinned edge of the neo-skirt (stent diameters; [0028]). As to claim 13, Dasi teaches the method of claim 1, wherein first bioprosthetic aortic valve is a previously-implanted bioprosthetic aortic valve, and the anatomical measurements include a distance from each native coronary artery ostium to an inflow end of the previously-implanted bioprosthetic aortic valve (Fig. 19A). As to claim 14, Dasi teaches the method of claim 13, wherein the anatomical measurements further include a distance from the inflow end to a native sinotubular junction (Fig. 13). As to claim 15, Dasi teaches the method of claim 13, wherein the anatomical measurements further include a parameter indicative of a spacing between the previously-implanted bioprosthetic aortic valve and a native aortic wall (Fig. 13). As to claim 16, Dasi teaches the method of claim 15, wherein the parameter is selected from the group consisting of a distance, a residual area, and a residual volume (Fig. 13). As to claim 17, Dasi teaches the method of claim 1, wherein the step of reviewing includes comparing a neo-skirt height value of the predetermined benchmark measurements with a coronary artery ostium height value of the anatomical measurements ([0068]-[0069]). As to claim 18, Dasi teaches the method of claim 1, wherein the step of reviewing includes comparing a neo-skirt height value of the predetermined benchmark measurements with a sinotubular junction height of the anatomical measurements (The simulation of the new design can be performed in the training database and its performance pertaining to the desired complication risk assessment can be compared to the current standard used devices.; [0075]). As to claim 19, Dasi teaches the method of claim 1, wherein the step of reviewing includes assessing a parameter indicative of a spacing between the first bioprosthetic aortic valve and native anatomy at a level of a native sinotubular junction (Strain, displacement (mm), and stress (MPa) at a region of calcium protrusion into the native tissue plotted over the balloon filling volume (%) in the retrospectively analyzed patient with aortic root rupture occurrence following TAVR.; [0017]). As to claim 20, Dasi teaches the method of claim 19, wherein the parameter is selected from the group consisting of a distance, a residual area, and a residual volume (Fig. 13). Claim Rejections - 35 USC § 103 In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. Claim 6 is rejected under 35 U.S.C. 103 as being unpatentable over Dasi in view of Dasi et al (US 20210346097 A1 hereinafter “Dasi2”). As to claim 6, Dasi teaches a method for modeling risk of a transcatheter valve deployment (Title) wherein various risk factors are discussed, however does not explicitly teach evaluating includes assessing a risk of sinus sequestration. Dasi2 teaches a method for predicting thrombosis for the heart valve replacements (Title) wherein the risk of thrombosis is detected in conjunction with Sinotubular junction (STJ) ([0076]), otherwise known as sinus sequestration. It would have been obvious for one ordinary skilled in the art before the effective filing date to have combined Dasi with Dasi2 since assessment of risk for sinus sequestration is well known within the field of valve deployment. Contact Information Any inquiry concerning this communication or earlier communications from the examiner should be directed to CLAIRE X WANG whose telephone number is (571)270-1051. The examiner can normally be reached M-F 9am-5pm. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Patricia Mallari can be reached at (571) 272-4729. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. CLAIRE X. WANG Supervisory Patent Examiner Art Unit 1774 /CLAIRE X WANG/Supervisory Patent Examiner, Art Unit 1774
Read full office action

Prosecution Timeline

Mar 24, 2025
Application Filed
Oct 05, 2026
Non-Final Rejection mailed — §101, §102, §103 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12770263
METHOD AND SYSTEM FOR HEALTH ESTIMATION OF BODY IMPLANTS
1y 10m to grant Granted Oct 20, 2026
Patent 12714964
ROBOT AIR FILTER
2y 9m to grant Granted Aug 25, 2026
Patent 12597165
CALIBRATION METHOD AND MEASUREMENT SYSTEM
2y 2m to grant Granted Apr 07, 2026
Patent 12469133
METHOD AND SYSTEM FOR DETECTING FUNDUS IMAGE BASED ON DYNAMIC WEIGHTED ATTENTION MECHANISM
2y 5m to grant Granted Nov 11, 2025
Patent 12432361
FIXED-SIZE IMAGE ALPHA CHANNEL COMPRESSION TECHNIQUES
2y 5m to grant Granted Sep 30, 2025
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
71%
Grant Probability
80%
With Interview (+8.2%)
3y 9m (~2y 0m remaining)
Median Time to Grant
Low
PTA Risk
Based on 223 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

By signing in, you agree to IP Author’s Terms of Service and Privacy Policy.

Free tier: 3 strategy analyses per month