Prosecution Insights
Last updated: November 13, 2026
Application No. 19/116,382

INDIRECT CIRCULATING WATER CONTACT-TYPE COOLING TOWER

Non-Final OA §112
Filed
Mar 28, 2025
Priority
Jul 17, 2023 — RE 10-2023-0092195 +1 more
Examiner
ALVARE, PAUL
Art Unit
3763
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Alen Co. Ltd.
OA Round
1 (Non-Final)
58%
Grant Probability
Moderate
1-2
OA Rounds
95%
With Interview

Examiner Intelligence

Grants 58% of resolved cases
58%
Career Allowance Rate
362 granted / 625 resolved
-12.1% vs TC avg
Strong +37% interview lift
Without
With
+36.7%
Interview Lift
resolved cases with interview
Typical timeline
Avg Prosecution
44 currently pending
Career history
675
Total Applications
across all art units

Office Action

§112
DETAILED ACTION Notice of Pre-AIA or AIA Status: The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Claim Objections Claim 4 is objected to because of the following informalities: “having given inclination or curvature surfaces” in ll. 3 should be rewritten to be -- having inclined or curved surfaces --, and will be interpreted accordingly. Appropriate correction is required. Claim Rejections - 35 USC § 112 The following is a quotation of 35 U.S.C. 112(b): (b) CONCLUSION.—The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the inventor or a joint inventor regards as the invention. Claims 1-9 are rejected under 35 U.S.C. 112(b) as being indefinite for failing to particularly point out and distinctly claim the subject matter which the inventor or a joint inventor, or for pre-AIA the applicant regards as the invention. Regarding Claim 1, the limitation “a plurality of heat transfer plates (220) adapted to allow returning circulating water, the outside air, and cooling water to flow along closed circuits (A) therein” in ll. 5 is indefinite, in context, since it cannot be discerned in what manner the outside air or cooling water is flowing through a closed circuit. From the specification and drawings it appears as though the outside air and cooling water flow in an open circuit. Further clarification is required. Regarding Claim 1, the limitation “cross-sectional shapes of PNG media_image1.png 36 58 media_image1.png Greyscale ” in ll. 15 is indefinite, in context, since it cannot be discerned what particular shape is being claimed. From the specification and drawings it appears as though the fastening bars comprise a U-shape and will be interpreted accordingly. Regarding Claim 1, the limitation “a closing plate (250) disposed on tops of the heat transfer plates (220) to prevent the outside air from being introduced into the closed circuits (A) and allow the outside air and the cooling water to flow in one direction” in ll. 9 is indefinite, in context, since it cannot be discerned in what manner the closing plate is disposed on the heat transfer plates. From the specification and drawings it appears as though the heat transfer plates are covered by the aforementioned closing plate; however the closing plate contacts a respective fastening bar and not the heat transfer plate. For Examination purposes and in accordance with the specification and drawings, “a closing plate (250) disposed on tops of the heat transfer plates (220) to prevent the outside air from being introduced into the closed circuits (A) and allow the outside air and the cooling water to flow in one direction” will be interpreted as –a closing plate (250) covering the tops of the heat transfer plates (220) and disposed on a fastening bar to prevent the outside air from being introduced into the closed circuits (A) and allow the outside air and the cooling water to flow in one direction…and the plurality of fastening bars (211) --. The term “tightly” in claims 6-9 is a relative term which renders the claim indefinite. The term “tightly” is not defined by the claim, the specification does not provide a standard for ascertaining the requisite degree, and one of ordinary skill in the art would not be reasonably apprised of the scope of the invention. For Examination purposes and in accordance with the specification and drawings, “tightly contacted with one another” will be interpreted as – contacting one another--. Allowable Subject Matter Claim 1 would be allowable if rewritten or amended to overcome the rejection(s) under 35 U.S.C. 112(b) or 35 U.S.C. 112 (pre-AIA ), 2nd paragraph, set forth in this Office action. Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to PAUL ALVARE whose telephone number is (571)272-8611. The examiner can normally be reached Monday-Friday 0930-1800. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Len Tran can be reached at (571) 272-1184. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /PAUL ALVARE/Primary Examiner, Art Unit 3763
Read full office action

Prosecution Timeline

Mar 28, 2025
Application Filed
Oct 19, 2026
Non-Final Rejection mailed — §112 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12791259
HEAT EXCHANGE ASSEMBLY, AND VEHICLE THERMAL MANAGEMENT SYSTEM
3y 11m to grant Granted Nov 10, 2026
Patent 12795858
IMMERSION HEAT EXCHANGE SYSTEM
2y 6m to grant Granted Nov 10, 2026
Patent 12795868
DATACENTER LIQUID COOLING ARRANGEMENT FOR REDUCING ICING RISKS OF DRY COOLERS
2y 3m to grant Granted Nov 10, 2026
Patent 12782059
COMBINATION HEAT EXCHANGER
2y 7m to grant Granted Nov 03, 2026
Patent 12782065
DRY COOLER ASSEMBLY AND METHOD OF ASSEMBLING THEREOF
2y 3m to grant Granted Nov 03, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
58%
Grant Probability
95%
With Interview (+36.7%)
Low
PTA Risk
Based on 625 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month