Notice of Pre-AIA or AIA Status
The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA .
Claim Rejections - 35 USC § 112
The following is a quotation of the first paragraph of 35 U.S.C. 112(a):
(a) IN GENERAL.—The specification shall contain a written description of the invention, and of the manner and process of making and using it, in such full, clear, concise, and exact terms as to enable any person skilled in the art to which it pertains, or with which it is most nearly connected, to make and use the same, and shall set forth the best mode contemplated by the inventor or joint inventor of carrying out the invention.
The following is a quotation of the first paragraph of pre-AIA 35 U.S.C. 112:
The specification shall contain a written description of the invention, and of the manner and process of making and using it, in such full, clear, concise, and exact terms as to enable any person skilled in the art to which it pertains, or with which it is most nearly connected, to make and use the same, and shall set forth the best mode contemplated by the inventor of carrying out his invention.
Claims 1-6 are rejected under 35 U.S.C. 112(a) or 35 U.S.C. 112 (pre-AIA ), first paragraph, as failing to comply with the written description requirement. The claim(s) contains subject matter which was not described in the specification in such a way as to reasonably convey to one skilled in the relevant art that the inventor or a joint inventor, or for applications subject to pre-AIA 35 U.S.C. 112, the inventor(s), at the time the application was filed, had possession of the claimed invention.
There is insufficient support in the application as originally filed for “triggering full closing of the monitor control valve mechanism by a pressure controller coupled to the monitor control valve and responsive to the first sensor”, as now recited in claim 1. The specification makes clear that the trigger valve is what does the “triggering”, and that the trigger valve (not the monitor control valve) is what responds to the first pressure sensor. (See para. 0029 and FIG 9, for example, where it is explained that trigger valve 28 senses the output pressure from first pressure sensor 31, while the controller 30 is what senses increased downstream pressure P2.)
Also there is insufficient support for a first sensor positioned at a point upstream of the monitor control valve, or a second sensor positioned at a point downstream of the monitor control valve, as now recited in claim 1. These sensors are arranged in parallel to the monitor control valve, and therefore cannot be positioned at a point upstream or downstream of the monitor control valve (being positioned at a point upstream or downstream would require them to be located along the same flowpath as the monitor control valve).
Claim Rejections - 35 USC § 103
The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action:
Claim(s) 1-6 as understood is/are rejected under 35 U.S.C. 103 as being unpatentable over Masias (US 2019/0072194) in view of either Law (US 2005/0155651) or Cecchinato (US 2003/0098071).
1. A method for preventing flow reversal
throttling a gas pressure (para. 0003) the worker regulator and the monitor control valve each having an inlet, an outlet (inlet and outlet considered clearly met), and a mechanism capable of movement within a range between and including a fully open position and a fully closed position (their valve elements move between open and closed positions; para. 0125, 0127, 0129, also the tables at paragraphs 0132 and 0134) to maintain a downstream delivery side gas flow pressure (e.g., para. 0129);
setting a threshold low pressure (X) for gas flow upstream of the monitor control valve (using the spring 551, which counteracts the sensed pressure at 556, where 556 must be of the set minimum pressure in order to keep valve 560 closed, thereby preventing the venting of chamber 539 and thereby keeping monitor control valve 520 open; see FIG 6);
continually sensing an actual gas flow pressure, P₁, with a first sensor positioned at a point upstream of the monitor control valve (sensing pressure at 556, which is connected to sense pressure upstream of monitor control valve 520; see FIG 6);
continually sensing an actual gas flow pressure, P₂, with a second sensor positioned at a point downstream of the monitor control valve (1st reading at chamber 538, 2nd alternative reading at 760 at FIG 8 and para. 0130, 3rd alternative reading at chamber 738), wherein the threshold low pressure (X) is set to be greater than the actual gas flow pressure (at least due to pressure reduction as flow occurs through 520 under the 1st reading, alternatively as flow occurs through 520 and 720 under the 2nd or 3rd reading); and
triggering full closing of the monitor control valve mechanism by a pressure controller coupled to the monitor control valve and responsive to the first sensor when the actual flow pressure upstream of the monitor control valve, P₁, falls below the threshold low pressure (X) to prevent reversal of flow in the gas supply line (when pressure at 556 drops, valve 560 opens thereby venting pressure from 539 and causing monitor control valve 520 to close; also see the table at para. 0132, 0134 which show that valve 520 closes when the inlet pressure falls).
Masias does not disclose the “natural gas pipeline” as claimed. However see Law (e.g., para. 0002) or Cecchinato (e.g., para. 0001), which teaches that it was known in the art before the effective filing date to use a similar device to regulate pressure in a natural gas pipeline. To regulate pressure in a natural gas pipeline using Masias’ device, it would have been obvious to use it in a natural gas pipeline, as similarly taught by either Law or Cecchinato
Regarding claim 2, Masias renders obvious the method of Claim 1, further comprising re-opening the closed monitor control valve when the actual flow pressure upstream of the monitor control valve, P₁, exceeds the threshold low pressure (X) (increased pressure 556 closes valve 560, thereby building pressure in 539 and causing valve 520 to open; also see the tables at para. 0132, 0134).
Regarding claim 3, rotary control valves were well-known in the art before the effective filing date (taken as admitted prior art as the previous assertion of official notice was not traversed), and it would have been obvious to use a rotary control valve instead of Masias’ linear control valve in order to similarly control pressure communication therethrough while enabling accurate throttling / fine-tuned regulation.
Regarding claim 4, Messias renders obvious the method of Claim 1, wherein the monitor control valve is a linear control valve (valve plug 528 moves linearly left and right in the orientation of FIG 6).
Regarding claim 5, Messias renders obvious the method of Claim 1, further comprising throttling gas flow with the monitor control valve when actual gas flow pressure at a point downstream of the monitor control valve, P₂, exceeds a predetermined pressure value (under the 1st reading – see para. 0113; alternatively the last sentence of para. 0115).
Regarding claim 6, Masias discloses the threshold pressures to be near the claimed values but not at the exact claimed values (e.g., see the tables at para. 0132 and 0134, using the conversion factor for bar to PSIG). However it would have been obvious to calibrate for the recited upstream and downstream pressure thresholds in order to provide for operation of Masias' system where a working environment thereof requires as much, as calibration parameters are routine variables that are manipulated in the art for particular applications in a given field.
Response to Arguments
Applicant's arguments filed 8/11/26 have been fully considered but they are not persuasive. Applicant argues that Masias’ regulator 720 does not “throttle”, and that it only moves from open to closed. In response, the regulator at least inherently throttles as the valve element moves between open and closed. What is more, the examiner disagrees with Applicant’s characterization of Masias. For example, see para. 0115 which explains the third mode of operation as follows:
“Because first chamber 538 is open to fluid outlet 526 and second chamber 539 is open to fluid inlet 524 and the fluid pressures at fluid inlet 524 and fluid outlet 526 will fluctuate when pressure regulator 520 is in the open position in the third mode of operation, pressure regulator 520 can modulate in response to the fluid pressure at fluid outlet 526 with the fluid pressure at fluid inlet 524 greater than the first setpoint.”
Also see claim 5, which explains that a pressure regulator is configured to modulate in response to fluid pressure at the fluid outlet.
This is what “pressure regulators” are understood by those of skill in the art to do. They “modulate” to maintain a setpoint pressure downstream of the regulator by sensing the downstream pressure and “throttling” towards their closed position to decrease downstream pressure if the sensed downstream pressure moves above the setpoint, or further opening to increase downstream pressure if the sensed downstream pressure moves below the pressure setpoint.
Conclusion
Applicant's amendment necessitated the new ground(s) of rejection presented in this Office action. Accordingly, THIS ACTION IS MADE FINAL. See MPEP § 706.07(a). Applicant is reminded of the extension of time policy as set forth in 37 CFR 1.136(a).
A shortened statutory period for reply to this final action is set to expire THREE MONTHS from the mailing date of this action. In the event a first reply is filed within TWO MONTHS of the mailing date of this final action and the advisory action is not mailed until after the end of the THREE-MONTH shortened statutory period, then the shortened statutory period will expire on the date the advisory action is mailed, and any nonprovisional extension fee (37 CFR 1.17(a)) pursuant to 37 CFR 1.136(a) will be calculated from the mailing date of the advisory action. In no event, however, will the statutory period for reply expire later than SIX MONTHS from the mailing date of this final action.
Any inquiry concerning this communication or earlier communications from the examiner should be directed to WILLIAM M MCCALISTER whose telephone number is (571)270-1869. The examiner can normally be reached M-F from 7am to 6pm.
If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, CRAIG SCHNEIDER, can be reached at telephone number 571-272-3607, or Kenneth Rinehart can be reached at 571-272-4881. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300.
Information regarding the status of an application may be obtained from Patent Center. Status information for published applications may be obtained from Patent Center. Status information for unpublished applications is available through Patent Center for authorized users only. Should you have questions about access to Patent Center, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free).
Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) Form at https://www.uspto.gov/patents/uspto-automated- interview-request-air-form.
/WILLIAM M MCCALISTER/Primary Examiner, Art Unit 3753
10/23/26