Prosecution Insights
Last updated: November 04, 2026
Application No. 19/237,131

A CLOSURE DEVICE FOR VASCULAR PUNCTURE

Non-Final OA §102§103§112
Filed
Jun 13, 2025
Priority
Jun 14, 2024 — CN CN202410770427.3
Examiner
LABRANCHE, BROOKE N
Art Unit
3771
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Shanghai Kegang Medical Technology Co. Ltd.
OA Round
1 (Non-Final)
72%
Grant Probability
Favorable
1-2
OA Rounds
1y 7m
Est. Remaining
88%
With Interview

Examiner Intelligence

Grants 72% — above average
72%
Career Allowance Rate
344 granted / 480 resolved
+1.7% vs TC avg
Strong +16% interview lift
Without
With
+16.2%
Interview Lift
resolved cases with interview
Typical timeline
3y 0m
Avg Prosecution
79 currently pending
Career history
569
Total Applications
across all art units

Statute-Specific Performance

§101
0.6%
-39.4% vs TC avg
§103
44.4%
+4.4% vs TC avg
§102
31.2%
-8.8% vs TC avg
§112
20.6%
-19.4% vs TC avg
Black line = Tech Center average estimate • Based on career data from 480 resolved cases

Office Action

§102 §103 §112
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Drawings The drawings are objected to under 37 CFR 1.83(a). The drawings must show every feature of the invention specified in the claims. Therefore, a rear sleeve that is “a multi-lumen tube” (claim 6) and “a polygonal radially-shaped tube” (claim 1) must be shown or the feature(s) canceled from the claim(s). The drawings currently show a multilumen tube (FIG 5) OR a polygonal radially-shaped tube (FIG 4) but fails to show a combination which meets both limitations. No new matter should be entered. Corrected drawing sheets in compliance with 37 CFR 1.121(d) are required in reply to the Office action to avoid abandonment of the application. Any amended replacement drawing sheet should include all of the figures appearing on the immediate prior version of the sheet, even if only one figure is being amended. The figure or figure number of an amended drawing should not be labeled as “amended.” If a drawing figure is to be canceled, the appropriate figure must be removed from the replacement sheet, and where necessary, the remaining figures must be renumbered and appropriate changes made to the brief description of the several views of the drawings for consistency. Additional replacement sheets may be necessary to show the renumbering of the remaining figures. Each drawing sheet submitted after the filing date of an application must be labeled in the top margin as either “Replacement Sheet” or “New Sheet” pursuant to 37 CFR 1.121(d). If the changes are not accepted by the examiner, the applicant will be notified and informed of any required corrective action in the next Office action. The objection to the drawings will not be held in abeyance. Claim Rejections - 35 USC § 112 The following is a quotation of 35 U.S.C. 112(b): (b) CONCLUSION.—The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the inventor or a joint inventor regards as the invention. The following is a quotation of 35 U.S.C. 112 (pre-AIA ), second paragraph: The specification shall conclude with one or more claims particularly pointing out and distinctly claiming the subject matter which the applicant regards as his invention. Claims 1-9 are rejected under 35 U.S.C. 112(b) or 35 U.S.C. 112 (pre-AIA ), second paragraph, as being indefinite for failing to particularly point out and distinctly claim the subject matter which the inventor or a joint inventor (or for applications subject to pre-AIA 35 U.S.C. 112, the applicant), regards as the invention. Claim 1 recites ”the rear sleeve being a polygonal radially-shaped tube” in lines 11-12. The scope of this limitation is unclear to one of ordinary skill in the art particularly in view of the Figures 4 and 5. Particularly, it is not clear what should be considered “radially-shaped” since a tube is already understood to have a radial component, but the specification in [0026] discloses that FIG 4 shows the “polygonal radial tubular shape” and FIG 5 alternatively shows a multi-lumen tube, suggesting that a simple tube structure does not satisfy the conditions of a radially shaped tube. Claims 3-4 recite “the number of radiating arms” and claim 5 recites “its radiating arms”. Each instance is lacking proper antecedent basis for radiating arms. In combination with the above discussion of claim 1, it is unclear if radiating arms are an additional element of the rear sleeve or if the radiating arms are defined by the polygonal radially shape tube. Further regarding claim 5, it is unclear what amount of space should be considered ”sufficient” space between the radiating arms. One of ordinary skill in the art is unable to determine the scope of this limitations because the claim does not establish what the spacing should be sufficient for. Claim Rejections - 35 USC § 102 In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale, or otherwise available to the public before the effective filing date of the claimed invention. Claim(s) 1, 3, 5, and 7-9 are rejected under 35 U.S.C. 102(a)(1) as being anticipated by Yassinzadeh (US 2023/0380820). Regarding claim 1, Yassinzadeh discloses a tissue closure device for a vascular puncture site (42, FIGs 8A-8H), comprising: a proximal temporary closure device (90, [0037]); a delivery device (40, FIG 8A, [0044]) slidably movable along the axis of a main conduit (123; 40 is movable along the axis as 10 is inserted into 40, FIG 8B); an implant (121, [0040], FIG 1A and 8F); and a main handle (78) located distally (FIG 1, 2, 8B-8H) for controlling the temporary closure device ([0037-0038]); wherein the proximal temporary closure device is capable of actively changing its morphological size in diameter (See change in diameter of 90 from FIGs 1-2, [0037]); the delivery device is a hollow tubular structure sleeved over the exterior of the main conduit and is slidably movable along the axis of the main conduit towards or away from the temporary closure device (Because sheath 40 is fully slidable relative to the elements of device 10, [0044]); the implant is a hollow tubular structure enveloping the main conduit (121 is tubular in shape, FIG 1A-5, and is positioned within 123 such that is seals an annular gap thereof, FIG 1A. Therefore it is interpreted as enveloping the main conduit by fully covering an inner lumen wall thereof), moves slidably along the axis of the main conduit following the delivery device ([0043]), and is capable of expanding within tissue at the puncture site to achieve hemostasis (See expansion in FIG 4 relative to FIG 3, [0043] discloses the expansion due to swelling of the material); the distal main handle controls the morphological change of the temporary closure device via a traction wire (76, [0037-0038]); characterized in that the inner diameter of the main conduit (Particularly conduit 123’ shown in FIG 10A-10C, [0047]) is provided with a rear sleeve (126’/162), the rear sleeve being a polygonal radially-shaped tube (Tube shaped at 162 and polygon radially shaped due to barbs 160), having a central lumen which is circular in shape (Lumen passing therethrough shown in FIG 10B-10C), the inner diameter of said lumen being larger than the diameter of the traction wire (Although not numbered, traction wire 76 is shown as passing through the lumen, therefore the lumen is a larger diameter), and the traction wire being slidable within the rear sleeve (FIG 10A-10C shows slidable relative movement between the rear sleeve and the wire). Regarding claim 3, Yassinzadeh discloses the number of radiating arms of the rear sleeve is at least greater than three (FIG 10C shows more than three barbs 160). Regarding claim 5, Yassinzadeh discloses the rear sleeve has sufficient space between its radiating arms (FIG 10A-10C shows spacing between the radiating arms which is interpreted as being ‘sufficient’ to allow for expansion of the arms); when the rear sleeve is nested within an outer sleeve (The following limitations are interpreted as being optional because they follow a conditional “when” statement pertaining to an outer sleeve which is not positively recited element of the claim), the radiating arms serve as supports for fixation, maintaining the traction wire in a relatively central position, and the spaces between the radiating arms allow for the smooth or even venting of gases to expel excess gas generated during the retraction of the temporary closure device. Regarding claim 7, Yassinzadeh discloses the temporary closure device is a segment of external braided structure (mesh 74), covered with a layer of covering material (membrane 96, [0037]); the proximal and distal ends of the segment of external braided structure (77 and 75, FIG 1A) are provided with external limiting rings serving a fixation function ([0037]; 75 and 77 are rings which serve to define the proximal and distal ends of the mesh), and the external limiting rings constraining the segment of external braided structure to prevent it from unraveling ([0037] “The occlusion element 90 is held between the plug 77 and the proximal anchor 75 so that axial retraction of the rod in the proximal direction (to the left as shown in FIGS. 1 and 1A) foreshortens the occlusion element 90, causing the occlusion element to expand radially, as shown for example in FIG. 2” is understood as preventing unraveling of the braid structure because expansion is permitted). Regarding claim 8, Yassinzadeh discloses the main conduit is internally provided with an inner sleeve (71, FIG 1A); the outer diameter of the inner sleeve is smaller than the inner diameter of the external limiting ring (FIG 1A, because 71 is received within 75); the inner sleeve can be nested within the interior of the external limiting ring and within the external braided structure (FIG 1A); the inner sleeve extends into the space within the external limiting ring and the external braided structure (As shown in FIG 1A and 10A-10C). Regarding claim 9, Yassinzadeh discloses the rear sleeve is either abutted against the inner sleeve or spaced apart from it by an interval (FIGs 10A-10C shows 71 being slightly spaced apart from 162). Claim Rejections - 35 USC § 103 In the event the determination of the status of the application as subject to AIA 35 U.S.C. 102 and 103 (or as subject to pre-AIA 35 U.S.C. 102 and 103) is incorrect, any correction of the statutory basis (i.e., changing from AIA to pre-AIA ) for the rejection will not be considered a new ground of rejection if the prior art relied upon, and the rationale supporting the rejection, would be the same under either status. The following is a quotation of 35 U.S.C. 103 which forms the basis for all obviousness rejections set forth in this Office action: A patent for a claimed invention may not be obtained, notwithstanding that the claimed invention is not identically disclosed as set forth in section 102, if the differences between the claimed invention and the prior art are such that the claimed invention as a whole would have been obvious before the effective filing date of the claimed invention to a person having ordinary skill in the art to which the claimed invention pertains. Patentability shall not be negated by the manner in which the invention was made. Claim(s) 2 and 4 are rejected under 35 U.S.C. 103 as being unpatentable over Yassinzadeh (US 2023/0380820). Regarding claim 2, Yassinzadeh discloses the invention substantially as claimed, as set forth above for claim 1. Yassinzadeh discloses the inner diameter of the lumen of the rear sleeve is larger than the diameter of the traction wire (FIG 10A-10C and 11A) but is silent regarding the difference in diameter being 0.01 mm to 0.5 mm. However, it would have been obvious to one having ordinary skill in the art before the effective filing date of the claimed invention to cause the inner diameter of the lumen of the rear sleeve to be 0.01mm to 0.5 mm larger than the diameter of the traction wire since it has been held that “where the only difference between the prior art and the claims was a recitation of relative dimensions of the claimed device and a device having the claimed relative dimensions would not perform differently than the prior art device, the claimed device was not patentably distinct from the prior art device” Gardner v. TEC Syst., Inc., 725 F.2d 1338, 220 USPQ 777 (Fed. Cir. 1984), cert. denied, 469 U.S. 830, 225 SPQ 232 (1984). In the instant case, the device of Yassinzadeh would not operate differently with the claimed diameters and since the lumen should be sufficiently larger than the wire to allow for translation therebetween but not so great such that the overall diameter of the device is excessive, the device would function appropriately having the claimed diameters. Further, applicant places no criticality on the range claimed, indicating simply that the diameter is “preferably” be within the claimed ranges (specification pp. [0026]). Regarding claim 4, Yassinzadeh discloses the invention substantially as claimed, as set forth above for claim 1. Yassinzadeh is silent regarding the total number of radiating arms and therefore fails to disclose the number of radiating arms of the rear sleeve is an odd number. However, the number of radiating arms is limited to either an odd number or an even number. Therefore, it would have been obvious to one of ordinary skill in the art at the time of filing to select an odd number of radiating arms, because it would have been obvious to try by choosing from a finite number of identified, predictable solutions, with a reasonable expectation of success. KSR Int'l Co. v. Teleflex Inc., 550 U.S. 398, 415-421, 82 USPQ2d 1385, 1395-97 (2007). Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to BROOKE N LABRANCHE whose telephone number is (571)272-9775. The examiner can normally be reached M-F 8-5. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Elizabeth Houston can be reached at 5712727134. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /BROOKE LABRANCHE/Primary Examiner, Art Unit 3771
Read full office action

Prosecution Timeline

Jun 13, 2025
Application Filed
Aug 21, 2026
Non-Final Rejection mailed — §102, §103, §112 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12778703
MECHANISM FOR MANUALLY ACTIVATED TOOL ADJUSTMENT
2y 7m to grant Granted Nov 03, 2026
Patent 12773216
LIGATION CLIP
5y 12m to grant Granted Oct 27, 2026
Patent 12758246
MAGNETIC DEVICES FOR RESECTIONING A PORTION OF A BODILY ORGAN
3y 7m to grant Granted Oct 13, 2026
Patent 12751732
SURGICAL MEDICAL INSTRUMENT AND GRIPPING DEVICE
2y 4m to grant Granted Oct 06, 2026
Patent 12740799
DIRECTABLE TRACTION SYSTEMS AND METHODS
1y 9m to grant Granted Sep 22, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
72%
Grant Probability
88%
With Interview (+16.2%)
3y 0m (~1y 7m remaining)
Median Time to Grant
Low
PTA Risk
Based on 480 resolved cases by this examiner. Grant probability derived from career allowance rate.