Application No. 19/117,682

SYSTEM AND METHODS FOR MEASUREMENT OF PARAMETERS SUCH AS INTRACRANIAL PRESSURE

Non-Final OA §102
Filed
Apr 02, 2025
Priority
Oct 06, 2022 — provisional 63/413,875 +1 more
Examiner
CATTUNGAL, SANJAY
Art Unit
3798
Tech Center
3700 — Mechanical Engineering & Manufacturing
Assignee
Massachusetts Institute of Technology
OA Round
1 (Non-Final)
83%
Grant Probability
Favorable
1-2
OA Rounds
1y 5m
Est. Remaining
94%
With Interview

Examiner Intelligence

Grants 83% — above average
83%
Career Allowance Rate
871 granted / 1044 resolved
+13.4% vs TC avg
Moderate +10% lift
Without
With
+10.1%
Interview Lift
resolved cases with interview
Typical timeline
3y 1m
Avg Prosecution
29 currently pending
Career history
1082
Total Applications
across all art units

Statute-Specific Performance

§101
2.2%
-37.8% vs TC avg
§103
35.6%
-4.4% vs TC avg
§102
30.3%
-9.7% vs TC avg
§112
6.6%
-33.4% vs TC avg
Black line = Tech Center average estimate • Based on career data from 1044 resolved cases

Office Action

§102
DETAILED ACTION Notice of Pre-AIA or AIA Status The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA . Claim Rejections - 35 USC § 102 The following is a quotation of the appropriate paragraphs of 35 U.S.C. 102 that form the basis for the rejections under this section made in this Office action: A person shall be entitled to a patent unless – (a)(1) the claimed invention was patented, described in a printed publication, or in public use, on sale, or otherwise available to the public before the effective filing date of the claimed invention. (a)(2) the claimed invention was described in a patent issued under section 151, or in an application for patent published or deemed published under section 122(b), in which the patent or application, as the case may be, names another inventor and was effectively filed before the effective filing date of the claimed invention. Claim(s) 1-20 is/are rejected under 35 U.S.C. 102 a1/a2 as being anticipated by U. S. Publication No. 2010/0331684 to Ragauskas et al. Regarding Claims 1, 4, and 19, Ragauskas teaches a system comprising: at least one hardware processor; and at least one non-transitory computer-readable storage medium storing processor-executable instructions that, when executed by the at least one hardware processor, cause the at least one hardware processor to perform: obtaining a set of data identifying a measure of arterial blood pressure and a measure of volumetric cerebral blood flow of a patient (figs. 1c, 5 and para 015 teaches measure of volumetric cerebral blood flow); and outputting information, based at least in part on the set of data, indicating a measure of a value in absolute units of one or more of the following: intracranial pressure (ICP), intracranial compliance (ICC), and cerebrovascular resistance (CVR) (para 012 and 080 teaches value in absolute units of ICP, icc and cvr). Regarding Claim 2, Ragauskas teaches that one or more probes configured to perform measurements at a patient site and send information about the measurements to the at least one hardware processor, wherein the obtaining the set of data identifying a measure of arterial blood pressure and a measure of volumetric cerebral blood flow of a patient is based at least in part on the information about the measurements at the patient site (figs. 1c, 5 and para 015 teaches measure of volumetric cerebral blood flow). Regarding Claim 3, Ragauskas teaches that the measure of a value in absolute units of ICC is a measure of a value in absolute units of a regional ICC and/or wherein the measure of a value in absolute units of CVR is a measure of a value in absolute units of a regional CVR (para 051 and 072 teaches absolute value of cvr). Regarding Claim 5, Ragauskas teaches that the value indicated in the output information is a value in absolute units (para 051 and 072 teaches absolute value of icp). Regarding Claim 6, Ragauskas teaches that the measures of two or more parameters related to distension of a vessel and blood flow through the vessel comprise one or both of:(1) a measure of arterial blood pressure (para 015 and 051 teaches measure of arterial blood pressure); and(2) a measure of cerebral blood flow (para 015 teaches measure of volumetric cerebral blood flow). Regarding Claim 7, Ragauskas teaches that the measure of cerebral blood flow comprises a measure of cerebral blood flow velocity and/or a measure of volumetric cerebral blood flow (para 015 teaches measure of volumetric cerebral blood flow). Regarding Claim 8, Ragauskas teaches that the one or more probes comprise only a single probe (fig. 1a teaches an ultrasonic probe). Regarding Claim 9, Ragauskas teaches that the one or more probes comprise an ultrasound probe (fig. 1a teaches an ultrasonic probe). Regarding Claim 10, Ragauskas teaches that the information output by the at least one hardware processor indicates a measure of a value in absolute units of ICP (para 012 and 080). Regarding Claim 11, Ragauskas teaches that the measure of a value in absolute units of ICP is in the units of mmHg, pascals, bars, pounds per square inch (PSI), atmospheres, or a multiple thereof (para 012 and 080). Regarding Claim 12, Ragauskas teaches that the information output by the at least one hardware processor indicates a measure of a value in absolute units of ICC (para 014-016). Regarding Claim 13, Ragauskas teaches that the measure of a value in absolute units of ICC is in the units of mL/mmHg, mL/pascal, mL/bar, mE/PSI, mL/atmosphere, or a multiple thereof (para 012 and 080). Regarding Claim 14, Ragauskas teaches that the data identifying a measure of volumetric cerebral blood flow of a patient are calculated via integration of a measure of cerebral blood flow velocity using vessel diameter waveforms (para 0051 teaches diameter of ophthalmic artery for measurement of volumetric blood flow). Regarding Claim 15, Ragauskas teaches that the values of ICP, ICC, and/or CVR are calculated by feeding arterial blood pressure and volumetric cerebral blood flow waveforms to a modified physiologic model (para 015, 043, and 048-052 teaches using arterial blood pressure and volumetric cerebral blood flow to a physiological model). Regarding Claim 16, Ragauskas teaches a point-of-care system configured to perform a continuous, model-based, non- invasive, real-time, patient-specific measurement of a measure of intracranial pressure (para 008-012), intracranial compliance (para 0083), and/or cerebrovascular resistance (para 015 and 051). Regarding Claim 17, 18, and 20, Ragauskas teaches administering a treatment for relieving a neuropathological condition to a subject based at least in part on the obtained measure (para 12 teaches brain pathology treatment and fig. 5 teaches displaying intracranial pressure value/alerts). Conclusion Any inquiry concerning this communication or earlier communications from the examiner should be directed to SANJAY CATTUNGAL whose telephone number is (571)272-1306. The examiner can normally be reached M-F 9-5 EST. Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice. If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Keith Raymond can be reached at 571-270-1790. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300. Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000. /SANJAY CATTUNGAL/Primary Examiner, Art Unit 3798
Read full office action

Prosecution Timeline

Apr 02, 2025
Application Filed
Oct 01, 2026
Non-Final Rejection mailed — §102 (current)

Precedent Cases

Applications granted by this same examiner with similar technology

Patent 12788529
SURGICAL SYSTEM WITH MULTI-MODALITY IMAGE DISPLAY
7y 6m to grant Granted Nov 10, 2026
Patent 12788276
METHOD AND SYSTEM FOR DETERMINING AT LEAST ONE PRODUCTION VALUE FOR PRODUCING A CUSTOM-TAILORED COMPRESSION GARMENT FOR A LIMB AND COMPUTER PROGRAM
1y 9m to grant Granted Nov 10, 2026
Patent 12782272
MULTISPECTRAL SAMPLE ANALYSIS USING ABSORPTION SIGNATURES
4y 10m to grant Granted Nov 03, 2026
Patent 12778558
ENHANCEMENT OF LOCAL FEATURES IN ULTRASOUND
2y 8m to grant Granted Nov 03, 2026
Patent 12765864
ULTRASOUND DIAGNOSTIC APPARATUS AND DATA PROCESSING METHOD
2y 11m to grant Granted Oct 20, 2026
Study what changed to get past this examiner. Based on 5 most recent grants.

Strategy Recommendation AI-generated — please review before filing

Get a prosecution strategy drawn from examiner precedents, rejection analysis, and claim mapping.
Typically takes 5-10 seconds — AI-generated, attorney review required before filing

Prosecution Projections

1-2
Expected OA Rounds
83%
Grant Probability
94%
With Interview (+10.1%)
3y 1m (~1y 5m remaining)
Median Time to Grant
Low
PTA Risk
Based on 1044 resolved cases by this examiner. Grant probability derived from career allowance rate.

Sign in with your work email

Enter your email to receive a magic link. No password needed.

Personal email addresses (Gmail, Yahoo, etc.) are not accepted.

Free tier: 3 strategy analyses per month