DETAILED ACTION
Notice of Pre-AIA or AIA Status
The present application, filed on or after March 16, 2013, is being examined under the first inventor to file provisions of the AIA .
Double Patenting
The nonstatutory double patenting rejection is based on a judicially created doctrine grounded in public policy (a policy reflected in the statute) so as to prevent the unjustified or improper timewise extension of the “right to exclude” granted by a patent and to prevent possible harassment by multiple assignees. A nonstatutory double patenting rejection is appropriate where the conflicting claims are not identical, but at least one examined application claim is not patentably distinct from the reference claim(s) because the examined application claim is either anticipated by, or would have been obvious over, the reference claim(s). See, e.g., In re Berg, 140 F.3d 1428, 46 USPQ2d 1226 (Fed. Cir. 1998); In re Goodman, 11 F.3d 1046, 29 USPQ2d 2010 (Fed. Cir. 1993); In re Longi, 759 F.2d 887, 225 USPQ 645 (Fed. Cir. 1985); In re Van Ornum, 686 F.2d 937, 214 USPQ 761 (CCPA 1982); In re Vogel, 422 F.2d 438, 164 USPQ 619 (CCPA 1970); In re Thorington, 418 F.2d 528, 163 USPQ 644 (CCPA 1969).
A timely filed terminal disclaimer in compliance with 37 CFR 1.321(c) or 1.321(d) may be used to overcome an actual or provisional rejection based on nonstatutory double patenting provided the reference application or patent either is shown to be commonly owned with the examined application, or claims an invention made as a result of activities undertaken within the scope of a joint research agreement. See MPEP § 717.02 for applications subject to examination under the first inventor to file provisions of the AIA as explained in MPEP § 2159. See MPEP § 2146 et seq. for applications not subject to examination under the first inventor to file provisions of the AIA . A terminal disclaimer must be signed in compliance with 37 CFR 1.321(b).
The filing of a terminal disclaimer by itself is not a complete reply to a nonstatutory double patenting (NSDP) rejection. A complete reply requires that the terminal disclaimer be accompanied by a reply requesting reconsideration of the prior Office action. Even where the NSDP rejection is provisional the reply must be complete. See MPEP § 804, subsection I.B.1. For a reply to a non-final Office action, see 37 CFR 1.111(a). For a reply to final Office action, see 37 CFR 1.113(c). A request for reconsideration while not provided for in 37 CFR 1.113(c) may be filed after final for consideration. See MPEP §§ 706.07(e) and 714.13.
The USPTO Internet website contains terminal disclaimer forms which may be used. Please visit www.uspto.gov/patent/patents-forms. The actual filing date of the application in which the form is filed determines what form (e.g., PTO/SB/25, PTO/SB/26, PTO/AIA /25, or PTO/AIA /26) should be used. A web-based eTerminal Disclaimer may be filled out completely online using web-screens. An eTerminal Disclaimer that meets all requirements is auto-processed and approved immediately upon submission. For more information about eTerminal Disclaimers, refer to www.uspto.gov/patents/apply/applying-online/eterminal-disclaimer.
Claims 1 and 2 are rejected on the ground of nonstatutory double patenting as being unpatentable over claims 1 and 19 of U.S. Patent No. 12,388,295. Although the claims at issue are not identical, they are not patentably distinct from each other because instant claims 1 and 2 reflect a broader scope that are anticipated by corresponding limitations of claims 1 and 19 of US 12,388,292.
Instant claim 1
Claims 1 and 19 of US 12,388,292
A management method for managing electrical power supply for electrically powering electrical equipment of a crane, via a conversion circuit, from a primary power supply source capable of providing a primary power and from a rechargeable secondary power supply source capable of providing a secondary power, wherein said management method comprises:
monitoring of a requested general power which corresponds to a power requested by all the electrical equipment and monitoring of a charge level of the rechargeable secondary power supply source; and wherein
the management method implements, depending on said requested general power and said charge level, at least the following management modes:
a recharging mode in which the requested general power is zero and the primary power supply source is available and connected to the rechargeable secondary power supply source to recharge it according to its charge level;
a mixed recharging/powering mode in which the requested general power is non-zero, and the primary power supply source is available and connected, on the one hand, to the electrical equipment to electrically power them and, on the other hand, to the rechargeable secondary power supply source to recharge it depending on the charge level;
a main power supply mode in which the requested general power is non-zero, and only the primary power supply source is connected to the electrical equipment to electrically power them;
a hybrid power supply mode in which the requested general power is non-zero, and the primary power supply source and the rechargeable secondary power supply source are both connected to the electrical equipment to electrically power them; and
an autonomous power supply mode in which the requested general power is non-zero, and only the rechargeable secondary power supply source is connected to the electrical equipment to electrically power them according to the charge level;
wherein the electrical equipment are powered by an available maximum power which corresponds to a minimum between a maximum conversion power and a source power, wherein the maximum conversion power corresponds to a maximum power that can be delivered at the output of the conversion circuit and wherein the source power corresponds to:
the sum of the secondary power and of the primary power in the hybrid power supply mode;
the secondary power in the autonomous power supply mode;
the primary power in the main power supply mode; and
the primary power minus a recharging power used to recharge the rechargeable secondary power supply source in the mixed recharging/powering mode;
wherein the management method implements, in the autonomous power supply mode and in the hybrid power supply mode, an adaptation of the secondary power as a function at least of the charge level, said secondary power being lower than or equal to a secondary maximum power which corresponds to a maximum power that can be delivered by the rechargeable secondary power supply source,
wherein an allocation method for allocating the available maximum power over the different electrical equipment is implemented, regardless of the management mode amongst the hybrid power supply mode, the autonomous power supply mode, the main power supply mode and the mixed recharging/powering mode,
wherein, when the requested general power is non-zero, the following management modes are automatically implemented:
the autonomous power supply mode is automatically implemented if the primary power supply source is not available;
the main power supply mode or the mixed recharging/powering mode is automatically implemented according to the charge level of the rechargeable secondary power supply source, if the primary power supply source is available and if the requested general power is lower than the primary power; and
the hybrid power supply mode is automatically implemented if the primary power supply source is available and if the requested general power is higher than the primary power.
A management method for managing electrical power supply for electrically powering electrical equipment of a crane, via a conversion circuit, from a primary power supply source capable of providing a primary power and from a rechargeable secondary power supply source capable of providing a secondary power, wherein said management method comprises
a monitoring of a requested general power which corresponds to a power requested by all the electrical equipment and a monitoring of a charge level of the rechargeable secondary power supply source, and wherein
the management method implements, depending on said requested general power and said charge level, at least the following management modes:
a recharging mode in which the requested general power is zero and the primary power supply source is available and connected to the rechargeable secondary power supply source to recharge it according to its charge level;
a mixed recharging/powering mode in which the requested general power is non-zero, and the primary power supply source is available and connected, on the one hand, to the electrical equipment to electrically power them and, on the other hand, to the rechargeable secondary power supply source to recharge it depending on the charge level;
a main power supply mode in which the requested general power is non-zero, and only the primary power supply source is connected to the electrical equipment to electrically power them;
a hybrid power supply mode in which the requested general power is non-zero, and the primary power supply source and the rechargeable secondary power supply source are both connected to the electrical equipment to electrically power them; and
an autonomous power supply mode in which the requested general power is non-zero, and only the rechargeable secondary power supply source is connected to the electrical equipment to electrically power them according to the charge level;
wherein the electrical equipment are powered by an available maximum power which corresponds to a minimum between a maximum conversion power and a source power, wherein the maximum conversion power corresponds to a maximum power that can be delivered at the output of the conversion circuit and wherein the source power corresponds to:
the sum of the secondary power and of the primary power in the hybrid power supply mode;
the secondary power in the autonomous power supply mode;
the primary power in the main power supply mode; and
the primary power minus a recharging power used to recharge the rechargeable secondary power supply source in the mixed recharging/powering mode;
wherein the management method implements, in the autonomous power supply mode and in the hybrid power supply mode, an adaptation of the secondary power as a function at least of the charge level, said secondary power being lower than or equal to a secondary maximum power which corresponds to a maximum power that can be delivered by the rechargeable secondary power supply source,
wherein an allocation method for allocating the available maximum power over the different electrical equipment is implemented, regardless of the management mode amongst the hybrid power supply mode, the autonomous power supply mode, the main power supply mode and the mixed recharging/powering mode;
(Claim 19)
wherein, when the requested general power is non-zero, the following management modes are automatically implemented:
the autonomous power supply mode is automatically implemented if the primary power supply source is not available;
the main power supply mode or the mixed recharging/powering mode is automatically implemented according to the charge level of the rechargeable secondary power supply source, if the primary power supply source is available and if the requested general power is lower than the primary power; and
the hybrid power supply mode is automatically implemented if the primary power supply source is available and if the requested general power is higher than the primary power,
wherein the management method implements a selection, in the hybrid power supply mode and in the autonomous power supply mode, of a management sub-mode amongst several management sub-modes comprising at least: an automatic sub-mode in which the secondary power is monitored so as to correspond to ka times the secondary maximum power, wherein ka is a coefficient that is less than or equal to 1 and which decreases with the charge level until the charge level drops below a low threshold, wherein the coefficient ka is equal to kamax as long as the charge level of the rechargeable secondary power supply source is above a high threshold, then the coefficient ka is equal to kamin when the charge level is comprised between the low threshold and the high threshold, and finally the coefficient ka is zero when the charge level of the rechargeable secondary power supply source is below the low threshold, wherein kamax is higher than kamin; and an economical sub-mode in which the secondary power is monitored so as to correspond to ke times the secondary maximum power, wherein ke is a coefficient lower than ka and which decreases with the charge level until the charge level drops below a low threshold, wherein the coefficient ke is equal to kemax as long as the charge level of the rechargeable secondary power supply source is above the high threshold, then the coefficient ke is equal to kemin when the charge level of the rechargeable secondary power supply source is comprised between the low threshold and the high threshold, and finally the coefficient ke is zero when the charge level of the rechargeable secondary power supply source is below the low threshold, wherein kemax is higher than kemin, kamax is higher than kemax and kamin is higher than kemin.
Therefore as shown above, the scope of instant claim 1 reflects a broader scope that is anticipated by that of claim 19, including every limitation with the exception of the additional limitations beginning “wherein the management method implements…” (including the limitations of claim 1) of US 12,388,292.
Claim 2: the limitations of instant claim 2 are recited in claim 1 of ‘292 (see above, beginning “wherein the management method implements…”).
Claims 1 and 2 are rejected on the ground of nonstatutory double patenting as being unpatentable over claims 1 and 21 of U.S. Patent No. 11,916,433. Although the claims at issue are not identical, they are not patentably distinct from each other because instant claims 1 and 2 reflect a broader scope that are anticipated by corresponding limitations of claims 1 and 21 of US 11,916,433 (of record).
Instant claim 1
Claims 1 and 21 of US 11,916,433
A management method for managing electrical power supply for electrically powering electrical equipment of a crane, via a conversion circuit, from a primary power supply source capable of providing a primary power and from a rechargeable secondary power supply source capable of providing a secondary power, wherein said management method comprises:
monitoring of a requested general power which corresponds to a power requested by all the electrical equipment and monitoring of a charge level of the rechargeable secondary power supply source; and wherein
the management method implements, depending on said requested general power and said charge level, at least the following management modes:
a recharging mode in which the requested general power is zero and the primary power supply source is available and connected to the rechargeable secondary power supply source to recharge it according to its charge level;
a mixed recharging/powering mode in which the requested general power is non-zero, and the primary power supply source is available and connected, on the one hand, to the electrical equipment to electrically power them and, on the other hand, to the rechargeable secondary power supply source to recharge it depending on the charge level;
a main power supply mode in which the requested general power is non-zero, and only the primary power supply source is connected to the electrical equipment to electrically power them;
a hybrid power supply mode in which the requested general power is non-zero, and the primary power supply source and the rechargeable secondary power supply source are both connected to the electrical equipment to electrically power them; and
an autonomous power supply mode in which the requested general power is non-zero, and only the rechargeable secondary power supply source is connected to the electrical equipment to electrically power them according to the charge level;
wherein the electrical equipment are powered by an available maximum power which corresponds to a minimum between a maximum conversion power and a source power, wherein the maximum conversion power corresponds to a maximum power that can be delivered at the output of the conversion circuit and wherein the source power corresponds to:
the sum of the secondary power and of the primary power in the hybrid power supply mode;
the secondary power in the autonomous power supply mode;
the primary power in the main power supply mode; and
the primary power minus a recharging power used to recharge the rechargeable secondary power supply source in the mixed recharging/powering mode;
wherein the management method implements, in the autonomous power supply mode and in the hybrid power supply mode, an adaptation of the secondary power as a function at least of the charge level, said secondary power being lower than or equal to a secondary maximum power which corresponds to a maximum power that can be delivered by the rechargeable secondary power supply source,
wherein an allocation method for allocating the available maximum power over the different electrical equipment is implemented, regardless of the management mode amongst the hybrid power supply mode, the autonomous power supply mode, the main power supply mode and the mixed recharging/powering mode,
wherein, when the requested general power is non-zero, the following management modes are automatically implemented:
the autonomous power supply mode is automatically implemented if the primary power supply source is not available;
the main power supply mode or the mixed recharging/powering mode is automatically implemented according to the charge level of the rechargeable secondary power supply source, if the primary power supply source is available and if the requested general power is lower than the primary power; and
the hybrid power supply mode is automatically implemented if the primary power supply source is available and if the requested general power is higher than the primary power.
A management method for managing electrical power supply for electrically powering electrical equipment of a crane, via a conversion circuit, from a primary power supply source capable of providing a primary power and from a rechargeable secondary power supply source capable of providing a secondary power, wherein said management method comprises
a monitoring of a requested general power which corresponds to a power requested by all the electrical equipment and a monitoring of a charge level of the rechargeable secondary power supply source, and wherein
the management method implements, depending on said requested general power and said charge level, at least the following management modes:
a recharging mode in which the requested general power is zero and the primary power supply source is available and connected to the rechargeable secondary power supply source to recharge it according to its charge level;
a mixed recharging/powering mode in which the requested general power is non-zero, and the primary power supply source is available and connected, on the one hand, to the electrical equipment to electrically power them and, on the other hand, to the rechargeable secondary power supply source to recharge it depending on the charge level;
a main power supply mode in which the requested general power is non-zero, and only the primary power supply source is connected to the electrical equipment to electrically power them;
a hybrid power supply mode in which the requested general power is non-zero, and the primary power supply source and the rechargeable secondary power supply source are both connected to the electrical equipment to electrically power them; and
an autonomous power supply mode in which the requested general power is non-zero, and only the rechargeable secondary power supply source is connected to the electrical equipment to electrically power them according to the charge level;
wherein the electrical equipment are powered by an available maximum power which corresponds to a minimum between a maximum conversion power and a source power, wherein the maximum conversion power corresponds to a maximum power that can be delivered at the output of the conversion circuit and wherein the source power corresponds to:
the sum of the secondary power and of the primary power in the hybrid power supply mode;
the secondary power in the autonomous power supply mode;
the primary power in the main power supply mode; and
the primary power minus a recharging power used to recharge the rechargeable secondary power supply source in the mixed recharging/powering mode;
wherein the management method implements, in the autonomous power supply mode and in the hybrid power supply mode, an adaptation of the secondary power as a function at least of the charge level, said secondary power being lower than or equal to a secondary maximum power which corresponds to a maximum power that can be delivered by the rechargeable secondary power supply source,
(Claim 21)
wherein, when the requested general power is non-zero, the following management modes are automatically implemented:
the autonomous power supply mode is automatically implemented if the primary power supply source is not available;
the main power supply mode or the mixed recharging/powering mode is automatically implemented according to the charge level of the rechargeable secondary power supply source, if the primary power supply source is available and if the requested general power is lower than the primary power; and
the hybrid power supply mode is automatically implemented if the primary power supply source is available and if the requested general power is higher than the primary power,
wherein the management method implements a selection, in the hybrid power supply mode and in the autonomous power supply mode, of a management sub-mode amongst several management sub-modes comprising at least: an automatic sub-mode in which the secondary power is monitored so as to correspond to ka times the secondary maximum power, wherein ka is a coefficient that is less than or equal to 1 and which decreases with the charge level until the charge level drops below a low threshold; and an economical sub-mode in which the secondary power is monitored so as to correspond to ke times the secondary maximum power, wherein ke is a coefficient lower than ka and which decreases with the charge level until the charge level drops below a low threshold.
Thus, there are two differences between the recited claims. In the first difference, “wherein an allocation method for allocating the available maximum power over the different electrical equipment is implemented, regardless of the management mode amongst the hybrid power supply mode, the autonomous power supply mode, the main power supply mode and the mixed recharging/powering mode” is recited by the instant claim, but not claims 1 and 21 of ‘433. However, this limitation does not appear to be a patentable distinction, as claim 1 of ‘433 already recites “monitoring of a requested general power which corresponds to a power requested by all the electrical equipment and monitoring of a charge level of the rechargeable secondary power supply source; and wherein the management method implements, depending on said requested general power and said charge level, at least the following management modes…”, where the limitation at issue is a mere rewording of the same scope. The second difference is that ‘433 further recites “wherein the management method implements a selection, in the hybrid power supply mode and in the autonomous power supply mode, of a management sub-mode amongst several management sub-modes comprising at least…”. However, as a one-way test of distinctness is applied, instant claim 1 thus reflects a broader scope that is anticipated by those of claims 1 and 21 of ‘433.
Claim 2: the limitations of instant claim 2 are recited in claim 1 of ‘433 (see above, beginning “wherein the management method implements…”).
Allowable Subject Matter
Claims 3-25 are objected to as being dependent upon a rejected base claim, but would be allowable if rewritten in independent form including all of the limitations of the base claim and any intervening claims (without the filing of a Terminal Disclaimer).
Claims 1-25 would be allowable if a properly filed Terminal Disclaimer is used to overcome the rejection(s) under nonstatutory double patenting grounds set forth in this Office action.
The following is a statement of reasons for the indication of allowable subject matter: the most relevant prior art is considered to be Takashi (WO 2013/001674 A1, of record), which discloses a crane (Fig.1) with a similar power supply receiving a commercial source of power and utilizing a rechargeable secondary power supply source (42). Takashi also discloses similar operating modes: a recharging mode or mixed recharging powering mode, when the battery 41 is recharged (see Figs.6 and 7), a main power supply mode (Fig.4), and a hybrid power supply mode (Fig.5). However, Takashi does not explicitly disclose “monitoring of a requested general power” per se, as Takashi provides a control scheme where the “modes” are changed according to the voltage of the DC bus, which while related to a power consumption of the load, is not a “requested general power” per se (i.e. the voltage on the DC bus is a function of each of the power input from the commercial supply, regenerative power, power from the battery, and power consumption of the load, rather than a “requested general power”). Therefore, Takashi does not further clearly disclose some of the conditions of operating in the recited modes, e.g. “a recharging mode in which the requested general power is zero” or “an autonomous power supply mode in which the requested general power is non-zero, and only the rechargeable secondary power supply source is connected to the electrical equipment to electrically power them according to the charge level”.
Conclusion
Any inquiry concerning this communication or earlier communications from the examiner should be directed to Ryan Johnson whose telephone number is (571)270-1264. The examiner can normally be reached Monday - Friday, 9:00 AM - 5:00 PM.
Examiner interviews are available via telephone, in-person, and video conferencing using a USPTO supplied web-based collaboration tool. To schedule an interview, applicant is encouraged to use the USPTO Automated Interview Request (AIR) at http://www.uspto.gov/interviewpractice.
If attempts to reach the examiner by telephone are unsuccessful, the examiner’s supervisor, Menna Youssef can be reached at 571-270-3684. The fax phone number for the organization where this application or proceeding is assigned is 571-273-8300.
Information regarding the status of published or unpublished applications may be obtained from Patent Center. Unpublished application information in Patent Center is available to registered users. To file and manage patent submissions in Patent Center, visit: https://patentcenter.uspto.gov. Visit https://www.uspto.gov/patents/apply/patent-center for more information about Patent Center and https://www.uspto.gov/patents/docx for information about filing in DOCX format. For additional questions, contact the Electronic Business Center (EBC) at 866-217-9197 (toll-free). If you would like assistance from a USPTO Customer Service Representative, call 800-786-9199 (IN USA OR CANADA) or 571-272-1000.
/RYAN JOHNSON/Primary Examiner, Art Unit 2836